Detection and quantification of intraperitoneal fluid using electrical impedance tomography

被引:29
作者
Sadleir, RJ
Fox, RA
机构
[1] Univ Western Australia, Dept Phys, Crawley, WA 6009, Australia
[2] Royal Perth Hosp, Dept Med Phys, Perth, WA 6847, Australia
关键词
electrical impedance tomography; intraperitoneal bleeding; quantification;
D O I
10.1109/10.915715
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A prototype electrical impedance tomography system was evaluated prior to its use for the detection of intraperitoneal bleeding, with the assistance of patients undergoing continuous ambulatory peritoneal dialysis (CAPD), The system was sensitive enough to detect small amounts of dialysis fluid appearing in subtractive images over short time periods. Uniform sensitivity to blood appearing anywhere within the abdominal cavity was produced using a post-reconstructive filter that corrected for changes in apparent resistivity of anomalies with their radial position, The image parameter used as an indication of fluid quantity, the resistivity index, varied approximately linearly with the quantity of fluid added. A test of the system's response to the introduction of conductive fluid out of the electrode plane (when a blood-equivalent fluid was added to the stomach) found that the sensitivity of the system was about half that observed in the electrode plane. Breathing artifacts were found to upset quantitative monitoring of intraperitoneal bleeding, but only on time scales short compared with the fluid administration rate. Longer term breathing changes, such as those due to variations in the functional residual capacity of the lungs, should ultimately limit the sensitivity over long time periods.
引用
收藏
页码:484 / 491
页数:8
相关论文
共 15 条
  • [1] ACKROYD MH, 1973, DIGITAL FILTERS
  • [2] Monitoring changes in lung air and liquid volumes with electrical impedance tomography
    Adler, A
    Amyot, R
    Guardo, R
    Bates, JHT
    Berthiaume, Y
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (05) : 1762 - 1767
  • [3] BARBER DC, 1986, INFORMATION PROCESSI
  • [4] Imaging with electricity: Report of the European Concerted Action on Impedance Tomography
    Boone, K
    Barber, D
    Brown, B
    [J]. JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1997, 21 (06) : 201 - 232
  • [5] Brown B H, 1987, Clin Phys Physiol Meas, V8 Suppl A, P91, DOI 10.1088/0143-0815/8/4A/012
  • [6] COOPER KR, 1990, CHEST, V84, P29
  • [7] CYCLICAL VARIATIONS IN FRC AND OTHER RESPIRATORY VARIABLES IN RESTING MAN
    HLASTALA, MP
    WRANNE, B
    LENFANT, CJ
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1973, 34 (05) : 670 - 676
  • [8] THE ELECTRODE SYSTEM IN IMPEDANCE-BASED VENTILATION MEASUREMENT
    LUO, S
    AFONSO, VX
    WEBSTER, JG
    TOMPKINS, WJ
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (11) : 1130 - 1141
  • [9] NORDEGRAAF AV, 1997, CHEST, V111, P1222
  • [10] APPLIED POTENTIAL TOMOGRAPHY IN THE MEASUREMENT OF GASTRIC-EMPTYING IN INFANTS
    NOUR, S
    MANGNALL, YF
    DICKSON, JAS
    JOHNSON, AG
    PEARSE, RG
    [J]. JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 1995, 20 (01) : 65 - 72