Time-of-Flight Magnetic Resonance Angiography With Sparse Undersampling and Iterative Reconstruction: Comparison With Conventional Parallel Imaging for Accelerated Imaging

被引:29
作者
Yamamoto, Takayuki [1 ]
Fujimoto, Koji [1 ]
Okada, Tomohisa [1 ]
Fushimi, Yasutaka [1 ]
Stalder, Aurelien F. [2 ]
Natsuaki, Yutaka [3 ]
Schmidt, Michaela [2 ]
Togashi, Kaori [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Diagnost Imaging & Nucl Med, 54 Shogoin Kawaharacho, Kyoto, Kyoto 6068507, Japan
[2] Siemens Healthcare, Erlangen, Germany
[3] Siemens Med Solut USA Inc, Los Angeles, CA USA
关键词
sparse undersampling; iterative reconstruction; compressed sensing; time of flight; magnetic resonance angiography; MR-ANGIOGRAPHY; HIGH-RESOLUTION; COIL; ACQUISITIONS; GADOLINIUM; OCCLUSION; ANEURYSMS; STENOSIS; SIGNAL; SENSE;
D O I
10.1097/RLI.0000000000000221
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The aim of this study was to evaluate the clinical feasibility of accelerated time-of-flight (TOF) magnetic resonance angiography with sparse undersampling and iterative reconstruction (sparse TOF). Materials and Methods The local institutional review board approved the study protocols. Twenty healthy volunteers were recruited (mean age, 31.2 years; age range, 22-52 years; 14 men, 6 women). Both sparse TOF and parallel imaging (PI) TOF were obtained on a 3 T scanner. Acceleration factors were 3, 4, 5, 6, and 8 for sparse TOF (Sp 3x, Sp 4x, Sp 5x, Sp 6x, and Sp 8x, respectively) and 2, 3, 4, and 6 for PI TOF (PI 2x, PI 3x, PI 4x, and PI 6x, respectively). Images were reconstructed on the scanner, and maximum intensity projection images were subjected to visual evaluation, wherein each segment of the major brain arteries was independently evaluated by 2 radiologists on a 4-point scale (1, poor; 2, limited; 3, moderate/good quality for diagnosis; and 4, excellent). As a quantitative evaluation, the apparent contrast-to-background deviation (apparent CBD) was calculated at the level of the basilar artery and the pons. Results A total number of 1800 segments were subjectively evaluated. There was substantial agreement regarding vessel visualization ( = 0.759). Sparse TOF received scores above 3 (good for diagnosis) at any acceleration factor up to the third segments of major arteries. The middle and distal segments of PI 4x and PI 6x were graded below 3 (limited or poor diagnostic value). Sp 3x, 4x, 5x, and 6x retained diagnostic information (graded above 3), even at distal segments. The apparent CBD of sparse TOF at any acceleration factor was equivalent to that of PI 2x, whereas the apparent CBD of PI 3x, PI 4x, and PI 6x attenuated with the acceleration factor. Conclusions Sparse TOF can achieve better image quality relative to PI TOF at higher acceleration factors. The diagnostic quality of distal branches (A2/3, M4, P4) was maintained with Sp 6x, which achieved a shorter acquisition time less than half of PI 2x.
引用
收藏
页码:372 / 378
页数:7
相关论文
共 54 条
[1]   Accelerated Late Gadolinium Enhancement Cardiac MR Imaging with Isotropic Spatial Resolution Using Compressed Sensing: Initial Experience1 [J].
Akcakaya, Mehmet ;
Rayatzadeh, Hussein ;
Basha, Tamer A. ;
Hong, Susie N. ;
Chan, Raymond H. ;
Kissinger, Kraig V. ;
Hauser, Thomas H. ;
Josephson, Mark E. ;
Manning, Warren J. ;
Nezafat, Reza .
RADIOLOGY, 2012, 264 (03) :691-699
[2]   Contrast-Enhanced MR Angiography Is Not More Accurate Than Unenhanced 2D Time-of-Flight MR Angiography for Determining ≥70% Internal Carotid Artery Stenosis [J].
Babiarz, L. S. ;
Romero, J. M. ;
Murphy, E. K. ;
Brobeck, B. ;
Schaefer, P. W. ;
Gonzalez, R. G. ;
Lev, M. H. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (04) :761-768
[3]   Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory [J].
Barger, AV ;
Block, WF ;
Toropov, Y ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) :297-305
[4]   A Fast Iterative Shrinkage-Thresholding Algorithm for Linear Inverse Problems [J].
Beck, Amir ;
Teboulle, Marc .
SIAM JOURNAL ON IMAGING SCIENCES, 2009, 2 (01) :183-202
[5]  
Bhagat YA, 2007, AM J NEURORADIOL, V28, P293
[6]   Stable signal recovery from incomplete and inaccurate measurements [J].
Candes, Emmanuel J. ;
Romberg, Justin K. ;
Tao, Terence .
COMMUNICATIONS ON PURE AND APPLIED MATHEMATICS, 2006, 59 (08) :1207-1223
[7]   Free-Breathing Contrast-Enhanced Multiphase MRI of the Liver Using a Combination of Compressed Sensing, Parallel Imaging, and Golden-Angle Radial Sampling [J].
Chandarana, Hersh ;
Feng, Li ;
Block, Tobias K. ;
Rosenkrantz, Andrew B. ;
Lim, Ruth P. ;
Babb, James S. ;
Sodickson, Daniel K. ;
Otazo, Ricardo .
INVESTIGATIVE RADIOLOGY, 2013, 48 (01) :10-16
[8]   The effectiveness of 3T time-of-flight magnetic resonance angiography for follow-up evaluations after the stent-assisted coil embolization of cerebral aneurysms [J].
Cho, Won-Sang ;
Kim, Sam Soo ;
Lee, Seung Jin ;
Kim, Sung Hun .
ACTA RADIOLOGICA, 2014, 55 (05) :604-613
[9]   High resolution MR imaging in patients with symptomatic middle cerebral artery stenosis [J].
Chung, Gyung Ho ;
Kwak, Hyo Sung ;
Hwang, Seung Bae ;
Jin, Gong Yong .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (12) :4069-4074
[10]  
Chung TS, 1999, AM J NEURORADIOL, V20, P229