Accuracy of the Precision® point-of-care ketone test examined by liquid chromatography tandem-mass spectrometry (LC-MS/MS) in the same fingerstick sample

被引:21
作者
Janssen, Marcel J. W. [1 ]
Hendrickx, Ben H. E. [1 ]
Habets-van der Poel, Carin D. [4 ]
van den Bergh, Joop P. W. [2 ]
Haagen, Anton A. M. [3 ]
Bakker, Jaap A. [4 ]
机构
[1] VieCuri Med Ctr, Lab Clin Chem & Haematol, NL-5900 BX Venlo, Netherlands
[2] VieCuri Med Ctr, Dept Internal Med, NL-5900 BX Venlo, Netherlands
[3] VieCuri Med Ctr, Dept Pediat, NL-5900 BX Venlo, Netherlands
[4] Maastricht Univ Hosp, Lab Biochem Genet, Dept Clin Genet, Maastricht, Netherlands
关键词
beta-hydroxybutyrate; fingerstick; ketone; liquid chromatography tandem-mass spectrometry; point-of-care; Precision (R); BETA-HYDROXYBUTYRATE; DIABETIC-KETOACIDOSIS; BLOOD; D-3-HYDROXYBUTYRATE; DERIVATIZATION; MANAGEMENT; CHILDREN; PLASMA; ASSAYS; SERUM;
D O I
10.1515/CCLM.2010.351
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The Precision (R) (Abbott Diabetes Care) point-of- care biosensor test strips are widely used by patients with diabetes and clinical laboratories for measurement of plasma beta-hydroxybutyrate (beta-HB) concentrations in capillary blood samples obtained by fingerstick. In the literature, this procedure has been validated only against the enzymatic determination of beta-HB in venous plasma, i.e., the method to which the Precision (R) has been calibrated. Methods: In this study, the Precision (R) Xceed was compared to a methodologically different and superior procedure: determination of beta-HB by liquid chromatography tandem-mass spectrometry (LC-MS/MS) in capillary blood spots. Blood spots were obtained from the same fingerstick sample from out of which Precision (R) measurements were performed. Linearity was tested by adding varying amounts of standard to an EDTA venous whole blood matrix. Results: The Precision (R) was in good agreement with LC-MS/MS within the measuring range of 0.0-6.0 mmol/L (Passing and Bablok regression: slope = 1.20 and no significant intercept, R = 0.97, n = 59). Surprisingly, the Precision (R) showed non-linearity and full saturation at concentrations above 6.0 mmol/L, which were confirmed by a standard addition experiment. Results obtained at the saturation level varied between 3.0 and 6.5 mmol/L. Conclusions: The Precision (R) beta-HB test strips demonstrate good comparison with LC-MS/MS. Inter-individual variation around the saturation level, however, is large. Therefore, we advise reporting readings above 3.0 as >3.0 mmol/L. The test is valid for use in the clinically relevant range of 0.0-3.0 mmol/L. Clin Chem Lab Med 2010; 48:1781-4.
引用
收藏
页码:1781 / 1784
页数:4
相关论文
共 15 条
[1]   Sick day management in children and adolescents with diabetes [J].
Brink, Stu ;
Laffel, Lori ;
Likitmaskul, Supawadee ;
Liu, Li ;
Maguire, Ann M. ;
Olsen, Birthe ;
Silink, Martin ;
Hanas, Ragnar .
PEDIATRIC DIABETES, 2009, 10 :146-153
[2]   Development of a commercial amperometric biosensor electrode for the ketone D-3-hydroxybutyrate [J].
Forrow, NJ ;
Sanghera, GS ;
Walters, SJ ;
Watkin, JL .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (08) :1617-1625
[3]   Advantages to using capillary blood β-hydroxybutyrate determination for the detection and treatment of diabetic ketosis [J].
Guerci, B ;
Tubiana-Rufi, N ;
Bauduceau, B ;
Bresson, R ;
Cuperlier, A ;
Delcroix, C ;
Durain, D ;
Fermon, C ;
Le Floch, JP ;
Le Devehat, C ;
Melki, V ;
Monnier, L ;
Mosnier-Pudar, H ;
Taboulet, P ;
Hanaire-Broutin, H .
DIABETES & METABOLISM, 2005, 31 (04) :401-406
[4]   Bedside ketone determination in diabetic children with hyperglycemia and ketosis in the acute care setting [J].
Ham, MR ;
Okada, P ;
White, PC .
PEDIATRIC DIABETES, 2004, 5 (01) :39-43
[5]   Near patient blood ketone measurements and their utility in predicting diabetic ketoacidosis [J].
Harris, S ;
Ng, R ;
Syed, H ;
Hillson, R .
DIABETIC MEDICINE, 2005, 22 (02) :221-224
[6]   INHIBITION OF BACTERIAL D-3-HYDROXYBUTYRATE DEHYDROGENASE BY SUBSTRATES AND SUBSTRATE-ANALOGS [J].
KLUGER, R ;
TSUI, WC .
CANADIAN JOURNAL OF BIOCHEMISTRY, 1981, 59 (10) :810-815
[7]  
LI PK, 1980, CLIN CHEM, V26, P1713
[8]  
MCMURRAY CH, 1984, CLIN CHEM, V30, P421
[9]   Point-of-care test identifies diabetic ketoacidosis at triage [J].
Naunheim, R ;
Jang, TJ ;
Banet, G ;
Richmond, A ;
McGill, J .
ACADEMIC EMERGENCY MEDICINE, 2006, 13 (06) :683-685
[10]   Laboratory and clinical evaluation of assays for beta-hydroxybutyrate [J].
Porter, WH ;
Yao, HH ;
Karounos, DG .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1997, 107 (03) :353-358