Liquid distribution and hold-up measurement in counter current flow packed column by electrical capacitance tomography

被引:26
作者
Wu, Hao [1 ,2 ]
Buschle, Bill [1 ]
Yang, Yunjie [1 ]
Tan, Chao [2 ]
Dong, Feng [2 ]
Jia, Jiabin [1 ]
Lucquiaud, Mathieu [1 ]
机构
[1] Univ Edinburgh, Sch Engn, Edinburgh, Midlothian, Scotland
[2] Tianjin Univ, Sch Elect & Informat Engn, Tianjin, Peoples R China
基金
英国工程与自然科学研究理事会; 中国国家自然科学基金;
关键词
Liquid hold-up; Liquid distribution; Electrical capacitance tomography; Packed column; Calculation model; STRUCTURED PACKING; MASS-TRANSFER; BED; GAS; CONDUCTIVITY;
D O I
10.1016/j.cej.2018.07.016
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In order to meet the requirements and well suit for in-situ process measurement of industrial scale gas-liquid mass transfer applications, such as natural gas processing and post-combustion carbon capture, electrical capacitance tomography (ECT) is used to analyse the distribution of a liquid phase across the packing of a counter current gas-liquid packed column and to quantify the liquid hold-up. The new method eliminates the requirement of a fully flooded reference calibration and only requires vacant and dry calibration steps. The calculation procedure is simplified by using a normal sensitivity matrix which does not include the packing information. The validity of the proposed method was confirmed through finite element method (FEM) analysis studies to certificate neither packing geometry nor orientation relative to the tomography probe nor had a significant impact on phase identification. An experiment is conducted on a counter current gas-liquid packed bed column with 190mm diameter and polypropylene Sulzer Mellapak 250 Y as the packing. According to the experiment with various liquid load, the inclination angle of structured packing corrugation sheets has an impact on the radial distribution of liquid hold-up in the upper portions of packed beds and liquid hold-up fluctuations of similar to 0.5% are observable below the flooding limit and even at no gas flow conditions which can meet the empirical correlations from literature. The experiment results show that the proposed method provides the confidence to use ECT in the industrial field service in gas-liquid packed column to provide the real-time liquid distribution and local liquid hold-up measurement.
引用
收藏
页码:519 / 532
页数:14
相关论文
共 44 条
[1]   Mathematical modelling of mass-transfer and hydrodynamics in CO2 absorbers packed with structured packings [J].
Aroonwilas, A ;
Chakma, A ;
Tontiwachwuthikul, P ;
Veawab, A .
CHEMICAL ENGINEERING SCIENCE, 2003, 58 (17) :4037-4053
[2]   Combined phase distribution and particle velocity measurement in spout fluidized beds by ultrafast X-ray computed tomography [J].
Bieberle, Martina ;
Barthel, Frank .
CHEMICAL ENGINEERING JOURNAL, 2016, 285 :218-227
[3]  
Billet und R., 1988, Chemical Engineering and Technology, V11, P213
[4]   A capacitance probe and a new model to identify and predict the capacity of columns equipped with structured packings [J].
Brunazzi, E ;
Paglianti, A ;
Pintus, S .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2001, 40 (04) :1205-1212
[5]  
Bruneton E., 2002, P 7 INT C DIST ABS B, P1
[6]   An ultra fast electron beam x-ray tomography scanner [J].
Fischer, F. ;
Hoppe, D. ;
Schleicher, E. ;
Mattausch, G. ;
Flaske, H. ;
Bartel, R. ;
Hampel, U. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2008, 19 (09)
[7]   Experimental study of liquid spreading in structured packings [J].
Fourati, M. ;
Roig, V. ;
Raynal, L. .
CHEMICAL ENGINEERING SCIENCE, 2012, 80 :1-15
[8]   Characterizing the liquid dynamics in cocurrent gas-liquid flows in porous media using twin-plane electrical capacitance tomography [J].
Hamidipour, M. ;
Larachi, F. .
CHEMICAL ENGINEERING JOURNAL, 2010, 165 (01) :310-323
[9]   Investigation of mixing characteristics in a packed-bed external loop airlift bioreactor using tomography images [J].
Hamood-ur-Rehman, Mian ;
Dahman, Yaser ;
Ein-Mozaffari, Farhad .
CHEMICAL ENGINEERING JOURNAL, 2012, 213 :50-61
[10]   Estimation of the Amount of CO2 Absorbed by Measuring the Variation of Electrical Conductivity in Highly Concentrated Monoethanolamine Solvent Systems [J].
Han, Sang-Jun ;
Wee, Jung-Ho .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2016, 61 (02) :712-720