Intravoxel incoherent motion diffusion-weighted imaging in the liver: comparison of mono-, bi- and tri-exponential modelling at 3.0-T

被引:56
作者
Cercueil, Jean-Pierre [1 ,2 ]
Petit, Jean-Michel [1 ,3 ]
Nougaret, Stephanie [4 ]
Soyer, Philippe [5 ]
Fohlen, Audrey [6 ]
Pierredon-Foulongne, Marie-Ange [4 ]
Schembri, Valentina [4 ]
Delhom, Elisabeth [4 ]
Schmidt, Sabine [7 ]
Denys, Alban [7 ]
Aho, Serge [8 ]
Guiu, Boris [4 ]
机构
[1] Univ Burgundy, INSERM, U866, F-21079 Dijon, France
[2] CHU Univ Hosp, Dept Radiol, F-21079 Dijon, France
[3] CHU Univ Hosp, Dept Endocrinol Diabetol & Metab Dis, F-21079 Dijon, France
[4] St Eloi Univ Hosp, Dept Radiol, F-34295 Montpellier, France
[5] Hop 1 Lariboisiere, AP HP, Dept Body & Intervent Imaging, F-75475 Paris 10, France
[6] Univ Hosp, Dept Radiol, F-14011 Caen, France
[7] CHU Vaudois, Dept Radiol, CH-1011 Lausanne, Switzerland
[8] CHU Univ Hosp, Dept Biostat, F-21079 Dijon, France
关键词
Diffusion-weighted imaging; IVIM; Liver; Signal model; MRI; PROTON MR SPECTROSCOPY; PERFUSION FRACTION; DIAGNOSTIC-VALUE; BLOOD-FLOW; FAT; QUANTIFICATION; PARENCHYMA; CIRRHOSIS; FIBROSIS; DISEASE;
D O I
10.1007/s00330-014-3554-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To determine whether a mono-, bi- or tri-exponential model best fits the intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) signal of normal livers. The pilot and validation studies were conducted in 38 and 36 patients with normal livers, respectively. The DWI sequence was performed using single-shot echoplanar imaging with 11 (pilot study) and 16 (validation study) b values. In each study, data from all patients were used to model the IVIM signal of normal liver. Diffusion coefficients (D-i +/- standard deviations) and their fractions (f(i) +/- standard deviations) were determined from each model. The models were compared using the extra sum-of-squares test and information criteria. The tri-exponential model provided a better fit than both the bi- and mono-exponential models. The tri-exponential IVIM model determined three diffusion compartments: a slow (D-1 = 1.35 +/- 0.03 x 10(-3) mm(2)/s; f(1) = 72.7 +/- 0.9 %), a fast (D-2 = 26.50 +/- 2.49 x 10(-3) mm(2)/s; f(2) = 13.7 +/- 0.6 %) and a very fast (D-3 = 404.00 +/- 43.7 x 10(-3) mm(2)/s; f(3) = 13.5 +/- 0.8 %) diffusion compartment [results from the validation study]. The very fast compartment contributed to the IVIM signal only for b values a parts per thousand currency sign15 s/mm(2) The tri-exponential model provided the best fit for IVIM signal decay in the liver over the 0-800 s/mm(2) range. In IVIM analysis of normal liver, a third very fast (pseudo)diffusion component might be relevant.
引用
收藏
页码:1541 / 1550
页数:10
相关论文
共 40 条
  • [1] Anderson D.R., 2008, MODEL BASED INFERENC
  • [2] Measurement reproducibility of perfusion fraction and pseudodiffusion coefficient derived by intravoxel incoherent motion diffusion-weighted MR imaging in normal liver and metastases
    Andreou, A.
    Koh, D. M.
    Collins, D. J.
    Blackledge, M.
    Wallace, T.
    Leach, M. O.
    Orton, M. R.
    [J]. EUROPEAN RADIOLOGY, 2013, 23 (02) : 428 - 434
  • [3] Diffusion and perfusion imaging of the liver
    Chandarana, Hersh
    Taouli, Bachir
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2010, 76 (03) : 348 - 358
  • [4] Liver fibrosis: An intravoxel incoherent motion (IVIM) study
    Chow, April M.
    Gao, Darwin S.
    Fan, Shu Juan
    Qiao, Zhongwei
    Lee, Frank Y.
    Yang, Jian
    Man, Kwan
    Wu, Ed X.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (01) : 159 - 167
  • [5] Clark CA, 2000, MAGN RESON MED, V44, P852, DOI 10.1002/1522-2594(200012)44:6<852::AID-MRM5>3.0.CO
  • [6] 2-A
  • [7] MR-Diffusion Weighted Imaging of Healthy Liver Parenchyma: Repeatability and Reproducibility of Apparent Diffusion Coefficient Measurement
    Colagrande, Stefano
    Pasquinelli, Filippo
    Mazzoni, Lorenzo Nicola
    Belli, Giacomo
    Virgili, Gianni
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (04) : 912 - 920
  • [8] In Vivo Cardiac Diffusion-Weighted Magnetic Resonance Imaging Quantification of Normal Perfusion and Diffusion Coefficients With Intravoxel Incoherent Motion Imaging
    Delattre, Benedicte M. A.
    Viallon, Magalie
    Wei, Hongjiang
    Zhu, Yuemin M.
    Feiweier, Thorsten
    Pai, Vinay M.
    Wen, Han
    Croisille, Pierre
    [J]. INVESTIGATIVE RADIOLOGY, 2012, 47 (11) : 662 - 670
  • [9] Effects of microperfusion in hepatic diffusion weighted imaging
    Dijkstra, Hildebrand
    Baron, Paul
    Kappert, Peter
    Oudkerk, Matthijs
    Sijens, Paul E.
    [J]. EUROPEAN RADIOLOGY, 2012, 22 (04) : 891 - 899
  • [10] Duong TQ, 2000, MAGNET RESON MED, V43, P393, DOI 10.1002/(SICI)1522-2594(200003)43:3<393::AID-MRM11>3.0.CO