Intravoxel incoherent motion diffusion-weighted imaging in the liver: comparison of mono-, bi- and tri-exponential modelling at 3.0-T

被引:58
作者
Cercueil, Jean-Pierre [1 ,2 ]
Petit, Jean-Michel [1 ,3 ]
Nougaret, Stephanie [4 ]
Soyer, Philippe [5 ]
Fohlen, Audrey [6 ]
Pierredon-Foulongne, Marie-Ange [4 ]
Schembri, Valentina [4 ]
Delhom, Elisabeth [4 ]
Schmidt, Sabine [7 ]
Denys, Alban [7 ]
Aho, Serge [8 ]
Guiu, Boris [4 ]
机构
[1] Univ Burgundy, INSERM, U866, F-21079 Dijon, France
[2] CHU Univ Hosp, Dept Radiol, F-21079 Dijon, France
[3] CHU Univ Hosp, Dept Endocrinol Diabetol & Metab Dis, F-21079 Dijon, France
[4] St Eloi Univ Hosp, Dept Radiol, F-34295 Montpellier, France
[5] Hop 1 Lariboisiere, AP HP, Dept Body & Intervent Imaging, F-75475 Paris 10, France
[6] Univ Hosp, Dept Radiol, F-14011 Caen, France
[7] CHU Vaudois, Dept Radiol, CH-1011 Lausanne, Switzerland
[8] CHU Univ Hosp, Dept Biostat, F-21079 Dijon, France
关键词
Diffusion-weighted imaging; IVIM; Liver; Signal model; MRI; PROTON MR SPECTROSCOPY; PERFUSION FRACTION; DIAGNOSTIC-VALUE; BLOOD-FLOW; FAT; QUANTIFICATION; PARENCHYMA; CIRRHOSIS; FIBROSIS; DISEASE;
D O I
10.1007/s00330-014-3554-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To determine whether a mono-, bi- or tri-exponential model best fits the intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) signal of normal livers. The pilot and validation studies were conducted in 38 and 36 patients with normal livers, respectively. The DWI sequence was performed using single-shot echoplanar imaging with 11 (pilot study) and 16 (validation study) b values. In each study, data from all patients were used to model the IVIM signal of normal liver. Diffusion coefficients (D-i +/- standard deviations) and their fractions (f(i) +/- standard deviations) were determined from each model. The models were compared using the extra sum-of-squares test and information criteria. The tri-exponential model provided a better fit than both the bi- and mono-exponential models. The tri-exponential IVIM model determined three diffusion compartments: a slow (D-1 = 1.35 +/- 0.03 x 10(-3) mm(2)/s; f(1) = 72.7 +/- 0.9 %), a fast (D-2 = 26.50 +/- 2.49 x 10(-3) mm(2)/s; f(2) = 13.7 +/- 0.6 %) and a very fast (D-3 = 404.00 +/- 43.7 x 10(-3) mm(2)/s; f(3) = 13.5 +/- 0.8 %) diffusion compartment [results from the validation study]. The very fast compartment contributed to the IVIM signal only for b values a parts per thousand currency sign15 s/mm(2) The tri-exponential model provided the best fit for IVIM signal decay in the liver over the 0-800 s/mm(2) range. In IVIM analysis of normal liver, a third very fast (pseudo)diffusion component might be relevant.
引用
收藏
页码:1541 / 1550
页数:10
相关论文
共 40 条
[1]  
Anderson D.R., 2008, MODEL BASED INFERENC
[2]   Measurement reproducibility of perfusion fraction and pseudodiffusion coefficient derived by intravoxel incoherent motion diffusion-weighted MR imaging in normal liver and metastases [J].
Andreou, A. ;
Koh, D. M. ;
Collins, D. J. ;
Blackledge, M. ;
Wallace, T. ;
Leach, M. O. ;
Orton, M. R. .
EUROPEAN RADIOLOGY, 2013, 23 (02) :428-434
[3]   Diffusion and perfusion imaging of the liver [J].
Chandarana, Hersh ;
Taouli, Bachir .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 76 (03) :348-358
[4]   Liver fibrosis: An intravoxel incoherent motion (IVIM) study [J].
Chow, April M. ;
Gao, Darwin S. ;
Fan, Shu Juan ;
Qiao, Zhongwei ;
Lee, Frank Y. ;
Yang, Jian ;
Man, Kwan ;
Wu, Ed X. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (01) :159-167
[5]  
Clark CA, 2000, MAGN RESON MED, V44, P852, DOI 10.1002/1522-2594(200012)44:6<852::AID-MRM5>3.0.CO
[6]  
2-A
[7]   MR-Diffusion Weighted Imaging of Healthy Liver Parenchyma: Repeatability and Reproducibility of Apparent Diffusion Coefficient Measurement [J].
Colagrande, Stefano ;
Pasquinelli, Filippo ;
Mazzoni, Lorenzo Nicola ;
Belli, Giacomo ;
Virgili, Gianni .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (04) :912-920
[8]   In Vivo Cardiac Diffusion-Weighted Magnetic Resonance Imaging Quantification of Normal Perfusion and Diffusion Coefficients With Intravoxel Incoherent Motion Imaging [J].
Delattre, Benedicte M. A. ;
Viallon, Magalie ;
Wei, Hongjiang ;
Zhu, Yuemin M. ;
Feiweier, Thorsten ;
Pai, Vinay M. ;
Wen, Han ;
Croisille, Pierre .
INVESTIGATIVE RADIOLOGY, 2012, 47 (11) :662-670
[9]   Effects of microperfusion in hepatic diffusion weighted imaging [J].
Dijkstra, Hildebrand ;
Baron, Paul ;
Kappert, Peter ;
Oudkerk, Matthijs ;
Sijens, Paul E. .
EUROPEAN RADIOLOGY, 2012, 22 (04) :891-899
[10]  
Duong TQ, 2000, MAGNET RESON MED, V43, P393, DOI 10.1002/(SICI)1522-2594(200003)43:3<393::AID-MRM11>3.0.CO