Reconstruction of severe acetabular bone defects with porous metal augment in total hip arthroplasty: A finite element analysis study

被引:4
作者
Li, Pengyu [1 ,2 ]
Tang, Hao [3 ]
Liu, Xiaoyu [4 ]
Chen, Zhenxian [4 ]
Zhang, Xiaogang [1 ]
Zhou, Yixin [3 ]
Jin, Zhongmin [1 ,4 ,5 ]
机构
[1] Southwest Jiaotong Univ, Sch Mech Engn, Chengdu, Peoples R China
[2] Imperial Coll London, Fac Engn, Dept Bioengn, London, England
[3] Peking Univ, Beijing Jishuitan Hosp, Dept Orthopaed Surg, Clin Coll 4, Beijing, Peoples R China
[4] Xi An Jiao Tong Univ, Sch Mech Engn, Xian, Shaanxi, Peoples R China
[5] Univ Leeds, Sch Mech Engn, Leeds, W Yorkshire, England
基金
中国国家自然科学基金;
关键词
Total hip revision; acetabular bone defects; initial stability; contact mechanics; finite element analysis; MECHANICAL-PROPERTIES; POLYETHYLENE WEAR; SLIDING-DISTANCE; COMPONENT; TITANIUM;
D O I
10.1177/09544119211052377
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study aims to evaluate the reconstructive stability for Paprosky III acetabular defects after total hip arthroplasty using three different reconstruction strategies with trabecular metal (TM) augments. The acetabular bone defects examined were located in the ilium, the sciatic ramus and the pubic ramus. Different scenarios of acetabular reconstructions were simulated, including the non-reconstruction model (NRM), the complete reconstruction model (CRM), the two-point reconstruction model (TRM) and the superior edge reconstruction model (SRM). A primary hip replacement model (HRM) was also investigated to compare the initial stability with different reconstruction models. The gait cycle was incorporated in the model to investigate the dynamic variation within the contact mechanics parameters. By comparing the SRM and the TRM, the acetabular cup translation was more pronounced when the superior defect on the acetabulum remained unfixed. Comparison of the acetabular cup displacement and the interface micromotion of both HRM and CRM demonstrated that the prosthetic implant provided good support for the reconstructed acetabulum. With the use of a press-fit cup, the cup displacement was reduced remarkably, while its Von-Mises stress increased significantly. The results show that the CRM was the best reconstruction option. In terms of acetabular defects, future improvements should focus on the reconstructive stability in stress concentration areas, to ensure no significant stress-shielding or other factors contributing to loosening of the prosthesis.
引用
收藏
页码:179 / 187
页数:9
相关论文
共 27 条
[1]  
Adler E, 1992, J Arthroplasty, V7, P295, DOI 10.1016/0883-5403(92)90052-R
[2]   Long-term survival of the acetabular component after total hip arthroplasty with cement in patients with developmental dysplasia of the hip [J].
Chougle, A ;
Hemmady, MV ;
Hodgkinson, JP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (01) :71-79
[3]   The Harris-Galante porous-coated acetabular component with screw fixation - An average ten-year follow-up study [J].
Clohisy, JC ;
Harris, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01) :66-73
[4]   Biomedical applications of titanium and its alloys [J].
Elias, C. N. ;
Lima, J. H. C. ;
Valiev, R. ;
Meyers, M. A. .
JOM, 2008, 60 (03) :46-49
[5]   Mid-term results after revision total hip arthroplasty with custom-made acetabular implants in patients with Paprosky III acetabular bone loss [J].
Froeschen, F. S. ;
Randau, T. M. ;
Hischebeth, G. T. R. ;
Gravius, N. ;
Gravius, S. ;
Walter, S. G. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (02) :263-273
[6]   Reconstruction of Severe Acetabular Bone Defect with 3D Printed Ti6Al4V Augment: A Finite Element Study [J].
Fu, Jun ;
Ni, Ming ;
Chen, Jiying ;
Li, Xiang ;
Chai, Wei ;
Hao, Libo ;
Zhang, Guoqiang ;
Zhou, Yonggang .
BIOMED RESEARCH INTERNATIONAL, 2018, 2018
[7]   Finite element analysis of sliding distance and contact mechanics of hip implant under dynamic walking conditions [J].
Gao, Yongchang ;
Jin, Zhongmin ;
Wang, Ling ;
Wang, Manyi .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2015, 229 (06) :469-474
[8]   Minimum Five-Year Outcomes with Porous Tantalum Acetabular Cup and Augment Construct in Complex Revision Total Hip Arthroplasty [J].
Jenkins, Derek R. ;
Odland, Andrew N. ;
Sierra, Rafael J. ;
Hanssen, Arlen D. ;
Lewallen, David G. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (10) :e49
[9]   Spatial variation in mandibular bone elastic modulus and its effect on structural bending stiffness: A test case using the Tai Forest monkeys [J].
Le, Kim N. ;
Marsik, Matthew ;
Daegling, David J. ;
Duque, Ana ;
McGraw, William Scott .
AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2017, 162 (03) :516-532
[10]   Composition and mechanical properties of cancellous bone from the femoral head of patients with osteoporosis or osteoarthritis [J].
Li, BH ;
Aspden, RM .
JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 (04) :641-651