Different patterns of neointimal coverage between acute coronary syndrome and stable angina after various types of drug-eluting stents implantation; 9-month follow-up optical coherence tomography study

被引:38
作者
Kim, Jung-Sun [1 ]
Fan, Chunyu [2 ]
Choi, Donghoon [1 ]
Jang, Ik-Kyung [3 ]
Lee, Jung Myung [1 ]
Kim, Tae Hoon [1 ]
Park, Sang Min [1 ]
Paik, Sung Il [1 ]
Ko, Young-Guk [1 ]
Hong, Myeong-Ki [1 ]
Jang, Yangsoo [1 ]
Chung, Namsik [1 ]
机构
[1] Yonsei Univ, Coll Med, Div Cardiol, Yonsei Cardiovasc Ctr, Seoul 120752, South Korea
[2] ShanXi Med Univ, Hosp 1, Div Cardiol, Taiyuan, Peoples R China
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Div Cardiol, Boston, MA USA
关键词
Acute coronary syndrome; Drug-eluting stent; Tomography; Optical coherence; LARGE 2-INSTITUTIONAL COHORT; ROUTINE CLINICAL-PRACTICE; MYOCARDIAL-INFARCTION; THROMBOSIS; PACLITAXEL; PLACEMENT;
D O I
10.1016/j.ijcard.2009.07.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Acute coronary syndrome (ACS) is an independent risk factor for late stent thrombosis which might be related to the impaired vascular healing after drug-eluting stent (DES) due to the disruption of plaques and thrombus formation. Therefore, we investigated the vascular response after various DES implantations between ACS and stable angina pectoris (SAP) using optical coherence tomography (OCT). Methods: Ninety-one patients [49 ACS: 20 sirolimus-eluting (SES), 12 paclitaxel-eluting (PES) and 17 zotarolimus eluting stent (ZES) and 42 SAP: 15 SES, 12 PES and 15 ZES] underwent OCT at 9 months after stent implantation. Neointimal coverage and malapposition were evaluated in 21,939 struts in 2269-mm stented segments. Results: In the ACS group, the incidence of uncovered and malapposed struts was significantly higher (8.9 +/- 13.7 vs 2.9 +/- 6.2%, p=0.01 and 2.2 +/- 5.6 vs 0.5 +/- 2.0%, p=0.02). Among the three DESs tested, SES showed a significantly higher rate of uncovered struts in the ACS group (17.3 +/- 13.4 vs 4.4 +/- 6.2%, p=0.003). PES had a trend toward higher rate of uncovered and malapposed struts in the ACS groups (6.7 +/- 7.6 vs 4.0 +/- 9.0%, p=0.13) while ZES was similar in both groups. Conclusion: The patterns of neointimal coverage and malapposition at 9 months after DES implantation were different between ACS and SAP, and variable among the DES type between two groups. Therefore, the present study suggests that vascular response after DES implantation might be influenced by both clinical presentation and type of DES. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:341 / 346
页数:6
相关论文
共 38 条
[21]   Relationship between aspirin/clopidogrel resistance and intra-stent thrombi assessed by follow-up optical coherence tomography after drug-eluting stent implantation [J].
Park, Junbeom ;
Shin, Dong-Ho ;
Kim, Byeong-Keuk ;
Her, Ae-Young ;
Kim, Yong Hoon ;
Choi, Hyun Hee ;
Kim, Jung-Sun ;
Ko, Young-Guk ;
Choi, Donghoon ;
Jang, Yangsoo ;
Hong, Myeong-Ki .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2013, 14 (12) :1181-1186
[22]   Randomized comparison of 9-month stent strut coverage of biolimus and everolimus drug-eluting stents assessed by optical coherence tomography in patients with ST-segment elevation myocardial infarction. Long-term (5-years) clinical follow-up (ROBUST trial) [J].
Jakl, Martin ;
Cervinka, Pavel ;
Kanovsky, Jan ;
Kala, Petr ;
Poloczek, Martin ;
Cervinkova, Michaela ;
Bezerra, Hiram G. ;
Valenta, Zdenek ;
Costa, Marco Aurelio .
CARDIOLOGY JOURNAL, 2023, 30 (06) :921-928
[23]   Comparison of neointimal coverage between ultrathin biodegradable polymer-coated sirolimus-eluting stents and durable polymer-coated everolimus-eluting stents: 6 months optical coherence tomography follow-up from the TAXCO study [J].
Abhyankar, Atul ;
Abizaid, Alexandre ;
Chamie, Daniel ;
Rathod, Mihir .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 97 (03) :423-430
[24]   Coronary arterial repair in patients with stable angina pectoris or acute coronary syndrome after ultrathin biodegradable polymer sirolimus-eluting stent implantation at 1-year follow-up by coronary angioscopy [J].
Ichikawa, Minoru ;
Matsuoka, Yuki ;
Hasebe, Terumitsu .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2023, 102 (06) :1012-1019
[25]   Comparison of paclitaxel-eluting vs. everolimus-eluting stents implanted simultaneously in different lesions of the same coronary artery: 12-month follow-up with optical coherence tomography [J].
de la Torre Hernandez, Jose M. ;
Lee, Dae-Hyun ;
Garcia-Camarero, Tamara ;
Sainz Laso, Fermin ;
Zueco, Javier .
EUROINTERVENTION, 2013, 9 (08) :952-958
[26]   Early vascular healing after neXt-generation drug-eluting stent implantation in Patients with non-ST elevation acute Coronary syndrome: a randomized optical coherence Tomography imaging study (EXPECT) [J].
Ma, Wen-Rui ;
Li, Qian ;
Wang, Qin ;
Cheng, You-Wei ;
Nai, Chang-Sheng ;
Wang, Xin-Yu ;
Li, Zheng ;
Wang, Yang ;
Iqbal, Javaid ;
Bourantas, Christos V. ;
Zhang, Yao-Jun .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2024,
[27]   Optical coherence tomography follow-up 18 months after titanium-nitride-oxidecoated versus everolimus-eluting stent implantation in patients with acute coronary syndrome [J].
Karjalainen, Pasi ;
Paana, Tuomas ;
Ylitalo, Antti ;
Sia, Jussi ;
Nammas, Wail .
ACTA RADIOLOGICA, 2017, 58 (09) :1077-1084
[28]   Difference of Tissue Characteristics Between Early and Late Restenosis After Second-Generation Drug-Eluting Stents Implantation. An Optical Coherence Tomography Study [J].
Jinnouchi, Hiroyuki ;
Kuramitsu, Shoichi ;
Shinozaki, Tomohiro ;
Tomoi, Yusuke ;
Hiromasa, Takashi ;
Kobayashi, Yohei ;
Domei, Takenori ;
Soga, Yoshimitsu ;
Hyodo, Makoto ;
Shirai, Shinichi ;
Ando, Kenji .
CIRCULATION JOURNAL, 2017, 81 (04) :450-457
[29]   Favorable Vessel Healing After Nobori Biolimus A9-Eluting Stent Implantation - 6- and 12-Month Follow-up by Optical Coherence Tomography [J].
Konishi, Akihide ;
Shinke, Toshiro ;
Otake, Hiromasa ;
Takaya, Tomofumi ;
Nakagawa, Masayuki ;
Inoue, Takumi ;
Hariki, Hirotoshi ;
Osue, Tsuyoshi ;
Taniguchi, Yu ;
Iwasaki, Masamichi ;
Nishio, Ryo ;
Hiranuma, Noritoshi ;
Kinutani, Hiroto ;
Kuroda, Masaru ;
Takahashi, Hachidai ;
Terashita, Daisuke ;
Shite, Junya ;
Hirata, Ken-ichi .
CIRCULATION JOURNAL, 2014, 78 (08) :1882-1890
[30]   Incomplete Stent Apposition and Delayed Tissue Coverage Are More Frequent in Drug-Eluting Stents Implanted During Primary Percutaneous Coronary Intervention for ST-Segment Elevation Myocardial Infarction Than in Drug-Eluting Stents Implanted for Stable/Unstable Angina Insights From Optical Coherence Tomography [J].
Gonzalo, Nieves ;
Barlis, Peter ;
Serruys, Patrick W. ;
Garcia-Garcia, Hector M. ;
Onuma, Yoshinobu ;
Ligthart, Jurgen ;
Regar, Evelyn .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (05) :445-452