Different patterns of neointimal coverage between acute coronary syndrome and stable angina after various types of drug-eluting stents implantation; 9-month follow-up optical coherence tomography study

被引:38
作者
Kim, Jung-Sun [1 ]
Fan, Chunyu [2 ]
Choi, Donghoon [1 ]
Jang, Ik-Kyung [3 ]
Lee, Jung Myung [1 ]
Kim, Tae Hoon [1 ]
Park, Sang Min [1 ]
Paik, Sung Il [1 ]
Ko, Young-Guk [1 ]
Hong, Myeong-Ki [1 ]
Jang, Yangsoo [1 ]
Chung, Namsik [1 ]
机构
[1] Yonsei Univ, Coll Med, Div Cardiol, Yonsei Cardiovasc Ctr, Seoul 120752, South Korea
[2] ShanXi Med Univ, Hosp 1, Div Cardiol, Taiyuan, Peoples R China
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Div Cardiol, Boston, MA USA
关键词
Acute coronary syndrome; Drug-eluting stent; Tomography; Optical coherence; LARGE 2-INSTITUTIONAL COHORT; ROUTINE CLINICAL-PRACTICE; MYOCARDIAL-INFARCTION; THROMBOSIS; PACLITAXEL; PLACEMENT;
D O I
10.1016/j.ijcard.2009.07.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Acute coronary syndrome (ACS) is an independent risk factor for late stent thrombosis which might be related to the impaired vascular healing after drug-eluting stent (DES) due to the disruption of plaques and thrombus formation. Therefore, we investigated the vascular response after various DES implantations between ACS and stable angina pectoris (SAP) using optical coherence tomography (OCT). Methods: Ninety-one patients [49 ACS: 20 sirolimus-eluting (SES), 12 paclitaxel-eluting (PES) and 17 zotarolimus eluting stent (ZES) and 42 SAP: 15 SES, 12 PES and 15 ZES] underwent OCT at 9 months after stent implantation. Neointimal coverage and malapposition were evaluated in 21,939 struts in 2269-mm stented segments. Results: In the ACS group, the incidence of uncovered and malapposed struts was significantly higher (8.9 +/- 13.7 vs 2.9 +/- 6.2%, p=0.01 and 2.2 +/- 5.6 vs 0.5 +/- 2.0%, p=0.02). Among the three DESs tested, SES showed a significantly higher rate of uncovered struts in the ACS group (17.3 +/- 13.4 vs 4.4 +/- 6.2%, p=0.003). PES had a trend toward higher rate of uncovered and malapposed struts in the ACS groups (6.7 +/- 7.6 vs 4.0 +/- 9.0%, p=0.13) while ZES was similar in both groups. Conclusion: The patterns of neointimal coverage and malapposition at 9 months after DES implantation were different between ACS and SAP, and variable among the DES type between two groups. Therefore, the present study suggests that vascular response after DES implantation might be influenced by both clinical presentation and type of DES. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:341 / 346
页数:6
相关论文
共 38 条
  • [11] Tissue coverage and neointimal hyperplasia in overlap versus nonoverlap segments of drug-eluting stents 9 to 13 months after implantation: In vivo assessment with optical coherence tomography
    Gutierrez-Chico, Juan Luis
    Raeber, Lorenz
    Regar, Evelyn
    Okamura, Takayuki
    di Mario, Carlo
    van Es, Gerrit-Anne
    Windecker, Stephan
    Serruys, Patrick W.
    AMERICAN HEART JOURNAL, 2013, 166 (01) : 83 - +
  • [12] Comparison of vascular responses after different types of second-generation drug-eluting stents implantation detected by optical coherence tomography
    Ohtani, Hirofumi
    Kimura, Shigeki
    Sugiyama, Tomoyo
    Hishikari, Keiichi
    Misawa, Toru
    Mizusawa, Masafumi
    Hayasaka, Kazuto
    Yamakami, Yosuke
    Kojima, Keisuke
    Sagawa, Yuichiro
    Hikita, Hiroyuki
    Ashikaga, Takashi
    Takahashi, Atsushi
    Isobe, Mitsuaki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (02) : 177 - 186
  • [13] Neointimal coverage and stent strut apposition six months after implantation of a paclitaxel eluting stent in acute coronary syndromes: An optical coherence tomography study
    Davlouros, Periklis A.
    Nikokiris, George
    Karantalis, Vasileios
    Mavronasiou, Eleni
    Xanthopoulou, Ioanna
    Damelou, Anastasia
    Tsigkas, Grigorios
    Alexopoulos, Dimitrios
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 151 (02) : 155 - 159
  • [14] Stent Coverage and Neointimal Proliferation in Bare Metal Stents Postdilated With a Paclitaxel-Eluting Balloon Versus Everolimus-Eluting Stents Prospective Randomized Study Using Optical Coherence Tomography at 6-Month Follow-Up
    Poerner, Tudor C.
    Otto, Sylvia
    Gassdorf, Johannes
    Nitsche, Kristina
    Janiak, Florian
    Scheller, Bruno
    Goebel, Bjoern
    Jung, Christian
    Figulla, Hans R.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (06) : 760 - U53
  • [15] Comparison of 9-Month Angiographic Follow-Up and Long-Term Clinical Outcomes of Biodegradable Polymer Drug-Eluting Stents and Second-Generation Durable Polymer Drug-Eluting Stents in Patients Undergoing Single Coronary Artery Stenting
    Tsai, Ming-Lung
    Hsieh, Ming-Jer
    Chen, Chun-Chi
    Chang, Shang-Hung
    Wang, Chao-Yung
    Chen, Dong-Yi
    Yang, Chia-Hung
    Yeh, Jih-Kai
    Ho, Ming-Yun
    Hsieh, I-Chang
    ACTA CARDIOLOGICA SINICA, 2020, 36 (02) : 97 - 104
  • [16] Evaluation of long-term follow-up with neointimal coverage and stent apposition after sirolimus-eluting stent implantation by optical coherence tomography
    Li, Shan
    Gai, Luyue
    Yang, Tingshu
    Zhang, Li
    Xu, Xiuli
    Bai, Qicai
    Xu, Hang
    Wang, Yutang
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (05) : 768 - 775
  • [17] Drug-eluting stent implantation in patients with acute coronary syndrome - the Activity of Platelets after Inhibition and Cardiovascular Events: Optical Coherence Tomography (APICE OCT) study
    Chieffo, Alaide
    Buchanan, Gill Louise
    Parodi, Guido
    Versaci, Francesco
    Bianchi, Renato Maria
    Valenti, Renato
    Sacca, Salvatore
    Mongiardo, Annalisa
    Span, Simonetta
    Migliorini, Angela
    Spaccarotella, Carmen
    Reimers, Bernhard
    Antoniucci, David
    Indolfi, Ciro
    Ferrari, Angela
    Maehara, Akiko
    Mintz, Gary S.
    Colombo, Antonio
    EUROINTERVENTION, 2014, 10 (08) : 916 - 923
  • [18] Long-term (≥2 years) follow-up optical coherence tomographic study after sirolimus- and paclitaxel-eluting stent implantation: comparison to 9-month follow-up results
    Kim, Tae-Hoon
    Kim, Jung-Sun
    Kim, Byoung-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (06) : 875 - 881
  • [19] Neointimal characteristics comparison between biodegradable-polymer and durable-polymer drug-eluting stents: 3-month follow-up optical coherence tomography light property analysis from the RESTORE registry
    Tomoaki Kobayashi
    Yohei Sotomi
    Satoshi Suzuki
    Yuma Hamanaka
    Shimpei Nakatani
    Jouke Dijkstra
    Yoshinobu Onuma
    Patrick W. Serruys
    Yasushi Sakata
    Atsushi Hirayama
    Yoshiharu Higuchi
    The International Journal of Cardiovascular Imaging, 2020, 36 : 205 - 215
  • [20] Neointimal characteristics comparison between biodegradable-polymer and durable-polymer drug-eluting stents: 3-month follow-up optical coherence tomography light property analysis from the RESTORE registry
    Kobayashi, Tomoaki
    Sotomi, Yohei
    Suzuki, Satoshi
    Hamanaka, Yuma
    Nakatani, Shimpei
    Dijkstra, Jouke
    Onuma, Yoshinobu
    Serruys, Patrick W.
    Sakata, Yasushi
    Hirayama, Atsushi
    Higuchi, Yoshiharu
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (02) : 205 - 215