Different patterns of neointimal coverage between acute coronary syndrome and stable angina after various types of drug-eluting stents implantation; 9-month follow-up optical coherence tomography study

被引:38
|
作者
Kim, Jung-Sun [1 ]
Fan, Chunyu [2 ]
Choi, Donghoon [1 ]
Jang, Ik-Kyung [3 ]
Lee, Jung Myung [1 ]
Kim, Tae Hoon [1 ]
Park, Sang Min [1 ]
Paik, Sung Il [1 ]
Ko, Young-Guk [1 ]
Hong, Myeong-Ki [1 ]
Jang, Yangsoo [1 ]
Chung, Namsik [1 ]
机构
[1] Yonsei Univ, Coll Med, Div Cardiol, Yonsei Cardiovasc Ctr, Seoul 120752, South Korea
[2] ShanXi Med Univ, Hosp 1, Div Cardiol, Taiyuan, Peoples R China
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Div Cardiol, Boston, MA USA
关键词
Acute coronary syndrome; Drug-eluting stent; Tomography; Optical coherence; LARGE 2-INSTITUTIONAL COHORT; ROUTINE CLINICAL-PRACTICE; MYOCARDIAL-INFARCTION; THROMBOSIS; PACLITAXEL; PLACEMENT;
D O I
10.1016/j.ijcard.2009.07.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Acute coronary syndrome (ACS) is an independent risk factor for late stent thrombosis which might be related to the impaired vascular healing after drug-eluting stent (DES) due to the disruption of plaques and thrombus formation. Therefore, we investigated the vascular response after various DES implantations between ACS and stable angina pectoris (SAP) using optical coherence tomography (OCT). Methods: Ninety-one patients [49 ACS: 20 sirolimus-eluting (SES), 12 paclitaxel-eluting (PES) and 17 zotarolimus eluting stent (ZES) and 42 SAP: 15 SES, 12 PES and 15 ZES] underwent OCT at 9 months after stent implantation. Neointimal coverage and malapposition were evaluated in 21,939 struts in 2269-mm stented segments. Results: In the ACS group, the incidence of uncovered and malapposed struts was significantly higher (8.9 +/- 13.7 vs 2.9 +/- 6.2%, p=0.01 and 2.2 +/- 5.6 vs 0.5 +/- 2.0%, p=0.02). Among the three DESs tested, SES showed a significantly higher rate of uncovered struts in the ACS group (17.3 +/- 13.4 vs 4.4 +/- 6.2%, p=0.003). PES had a trend toward higher rate of uncovered and malapposed struts in the ACS groups (6.7 +/- 7.6 vs 4.0 +/- 9.0%, p=0.13) while ZES was similar in both groups. Conclusion: The patterns of neointimal coverage and malapposition at 9 months after DES implantation were different between ACS and SAP, and variable among the DES type between two groups. Therefore, the present study suggests that vascular response after DES implantation might be influenced by both clinical presentation and type of DES. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:341 / 346
页数:6
相关论文
共 38 条
  • [1] Evaluation of neointimal coverage and apposition with various drug-eluting stents over 12 months after implantation by optical coherence tomography
    Li, Shan
    Wang, Yutang
    Gai, Luyue
    Yang, Tingshu
    Liu, Hongbin
    Wang, Zhifeng
    Bai, Qicai
    Xu, Xiuli
    Chen, Yundai
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 162 (03) : 166 - 171
  • [2] Morphologic characteristics of late stent malapposition after drug-eluting stents implantation by optical coherence tomography follow-up
    Hou Jing-bo
    Liu Hui-min
    Ma Li-jia
    Yang Shuang
    Meng Ling-bo
    Han Zhi-gang
    Zhang Shuo
    Yu Bo
    CHINESE MEDICAL JOURNAL, 2010, 123 (05) : 581 - 584
  • [3] Comparative analysis of neointimal coverage with paclitaxel and zotarolimus drug-eluting stents, using optical coherence tomography 6 months after implantation
    Motreff, Pascal
    Souteyrand, Geraud
    Levesque, Sebastien
    Ouchchane, Lemlih
    Dauphin, Claire
    Sarry, Laurent
    Cassagnes, Jean
    Lusson, Jean-Rene
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2009, 102 (8-9) : 617 - 624
  • [4] Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: comparison with sirolimus-eluting stents
    Kim, J-S
    Jang, I-K
    Kim, J-S
    Kim, T. H.
    Takano, M.
    Kume, T.
    Hur, N. W.
    Ko, Y-G
    Choi, D.
    Hong, M-K
    Jang, Y.
    HEART, 2009, 95 (23) : 1907 - 1912
  • [5] Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography
    Matsumoto, Daisuke
    Shite, Junya
    Shinke, Toshiro
    Otake, Hiromasa
    Tanino, Yusuke
    Ogasawara, Daisuke
    Sawada, Takahiro
    Paredes, Oscar Luis
    Hirata, Ken-ichi
    Yokoyama, Mitsuhiro
    EUROPEAN HEART JOURNAL, 2007, 28 (08) : 961 - 967
  • [6] Evaluation neointimal coverage in patients with coronary artery aneurysm formation after drug-eluting stent implantation by optical coherence tomography
    Tian Feng
    Chen Yundai
    Liu Hongbin
    Chen Lian
    Sun Zhijun
    Guo Jun
    Jin Qinhua
    Zhang Tao
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (08) : 1677 - 1683
  • [7] Evaluation of neointimal coverage in patients with coronary artery aneurysm formation after drug-eluting stent implantation by optical coherence tomography
    Tian Feng
    Chen Yun-dai
    Chen Lian
    Sun Zhi-jun
    Guo Jun
    Jin Qin-hua
    Liu Chang-fu
    Wang Jin-da
    Liu Hong-bin
    CHINESE MEDICAL JOURNAL, 2013, 126 (11) : 2092 - 2097
  • [8] Differential healing response attributed to culprit lesions of patients with acute coronary syndromes and stable coronary artery after implantation of drug-eluting stents: An optical coherence tomography study
    Raeber, Lorenz
    Zanchin, Thomas
    Baumgartner, Sandro
    Taniwaki, Masanori
    Kalesan, Bindu
    Moschovitis, Aris
    Garcia-Garcia, Hector M.
    Justiz, Joern
    Pilgrim, Thomas
    Wenaweser, Peter
    Meier, Bernhard
    Jueni, Peter
    Windecker, Stephan
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 173 (02) : 259 - 267
  • [9] Correlation of angiographic late loss with neointimal coverage of drug-eluting stent struts on follow-up optical coherence tomography
    Kim, Byeong-Keuk
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (06) : 1289 - 1297
  • [10] Evaluation neointimal coverage in patients with coronary artery aneurysm formation after drug-eluting stent implantation by optical coherence tomography
    Tian Feng
    Chen Yundai
    Liu Hongbin
    Chen Lian
    Sun Zhijun
    Guo Jun
    Jin Qinhua
    Zhang Tao
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1677 - 1683