Failed extubation of a double-lumen tube requiring a cricoid split

被引:3
作者
Probert, DJ [1 ]
Hardman, JG [1 ]
机构
[1] Royal Brisbane Hosp, Dept Anaesthesia & Perioperat Med, Brisbane, Qld 4029, Australia
关键词
airway : difficult extubation; double-lumen tube; cricoid split;
D O I
10.1177/0310057X0303100517
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Following a five-hour procedure, it was not possible to remove a double-lumen endobronchial tube that had been placed to facilitate the removal of a massive spleen from a 45-year-old female. The tube had been passed easily at the start of surgery, but was firmly stuck at the level of the cricoid at the end of surgery. Surgical removal of the tube by a cricoid split was required 48 hours later Consideration of previous airway manipulations, careful choice of airway devices and regular checks of airway patency around tracheal tubes during lengthy procedures may prevent similar events in the future.
引用
收藏
页码:584 / 587
页数:4
相关论文
共 50 条
[41]   A spray-as-you-go airway topical anesthesia attenuates cardiovascular responses for double-lumen tube tracheal intubation [J].
Changlin Chen ;
Di Wen ;
Yizheng Wang ;
Hongqiong Li ;
Qi Yu ;
Mao Li .
BMC Anesthesiology, 22
[42]   The relationship between tracheal width and left bronchial width: Implications for left-sided double-lumen tube selection [J].
Brodsky, JB ;
Malott, K ;
Angst, M ;
Fitzmaurice, BG ;
Kee, SP ;
Logan, L .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2001, 15 (02) :216-217
[43]   Double-lumen tube intubation using video laryngoscopy causes a milder cardiovascular response compared to classic direct laryngoscopy [J].
Wei, Wei ;
Tian, Ming .
PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2016, 32 (01) :35-39
[44]   Evaluation of the Double-Lumen Tube Vivasight-DL (DLT-ETView): A Prospective Single-Center Study [J].
Massot, Julien ;
Dumand-Nizard, Virginie ;
Fischler, Marc ;
Le Guen, Morgan .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2015, 29 (06) :1544-1549
[45]   Comparison of the Airtraq laryngoscope and the GlideScope for double-lumen tube intubation in patients with predicted normal airways: a prospective randomized trial [J].
Jie Yi ;
Yahong Gong ;
Xiang Quan ;
Yuguang Huang .
BMC Anesthesiology, 15
[46]   A spray-as-you-go airway topical anesthesia attenuates cardiovascular responses for double-lumen tube tracheal intubation [J].
Chen, Changlin ;
Wen, Di ;
Wang, Yizheng ;
Li, Hongqiong ;
Yu, Qi ;
Li, Mao .
BMC ANESTHESIOLOGY, 2022, 22 (01)
[47]   The feasibility and accuracy of the method for selecting the optimal size of double-lumen tube in thoracic surgery: a prospective, randomized controlled trial [J].
Cui, Guangying ;
Zhao, Li ;
Chi, Cheng ;
Liang, Shujuan ;
Liu, Zhuo .
SCIENTIFIC REPORTS, 2024, 14 (01)
[48]   Comparison of the Airtraq laryngoscope and the GlideScope for double-lumen tube intubation in patients with predicted normal airways: a prospective randomized trial [J].
Yi, Jie ;
Gong, Yahong ;
Quan, Xiang ;
Huang, Yuguang .
BMC ANESTHESIOLOGY, 2015, 15
[49]   The single-connector technique for initial placement of double-lumen tubes [J].
Pfitzner, J ;
Alexander, HI ;
Hung, PK .
ANAESTHESIA AND INTENSIVE CARE, 2004, 32 (05) :685-692
[50]   A simple blind placement of the left-sided double-lumen tubes [J].
Zong, Zhi Jun ;
Shen, Qi Ying ;
Lu, Yao ;
Li, Yuan Hai .
MEDICINE, 2016, 95 (45)