Failed extubation of a double-lumen tube requiring a cricoid split

被引:3
作者
Probert, DJ [1 ]
Hardman, JG [1 ]
机构
[1] Royal Brisbane Hosp, Dept Anaesthesia & Perioperat Med, Brisbane, Qld 4029, Australia
关键词
airway : difficult extubation; double-lumen tube; cricoid split;
D O I
10.1177/0310057X0303100517
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Following a five-hour procedure, it was not possible to remove a double-lumen endobronchial tube that had been placed to facilitate the removal of a massive spleen from a 45-year-old female. The tube had been passed easily at the start of surgery, but was firmly stuck at the level of the cricoid at the end of surgery. Surgical removal of the tube by a cricoid split was required 48 hours later Consideration of previous airway manipulations, careful choice of airway devices and regular checks of airway patency around tracheal tubes during lengthy procedures may prevent similar events in the future.
引用
收藏
页码:584 / 587
页数:4
相关论文
共 50 条
[21]   Prediction of Double-Lumen Tube Size By Ultrasonography for Asian Women: A Prospective Observational Study [J].
Liu, Shiqing ;
Zhou, Jing ;
Qi, Wenxu ;
Cheng, Lili ;
Dong, Youjing .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2021, 35 (05) :1410-1415
[22]   One lung ventilation: double-lumen tube with vs. without carinal hook [J].
Potocnik, Iztok ;
Andjelkovic, Lea ;
Markovic-Bozic, Jasmina .
SIGNA VITAE, 2018, 14 (01) :27-29
[23]   Evaluating the precision of ultrasound versus computed tomography-guided measurement of cricoid cartilage diameter for double-lumen tube selection in thoracic surgery: A randomised comparative study [J].
Mathew, Roshni M. ;
Gautam, Shefali ;
Raman, Rajesh ;
Rai, Anurag ;
Srivastava, Vinod K. ;
Singh, Manish K. .
INDIAN JOURNAL OF ANAESTHESIA, 2024, 68 (10) :896-901
[24]   Diagnosis, procedure and conservative therapy of a bronchial rupture after intubation with double-lumen tube. [J].
Eichler, W ;
Sedemund-Adib, B ;
Schumacher, J ;
Klotz, KF .
ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 1999, 34 (01) :66-70
[25]   Bronchial blocker compared to double-lumen tube for one-lung ventilation during thoracoscopy [J].
Bauer, C ;
Winter, C ;
Hentz, JG ;
Ducrocq, X ;
Steib, A ;
Dupeyron, JP .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2001, 45 (02) :250-254
[26]   Insertion depth of left-sided double-lumen endobroncheal tube: A new predictive formula [J].
Eldawlatly, Abdelazeem ;
Alqatari, Ahmed ;
Kanchi, Naveed ;
Marzouk, Amir .
SAUDI JOURNAL OF ANAESTHESIA, 2019, 13 (03) :227-230
[27]   Video Laryngoscopy Versus Direct Laryngoscopy for Double-Lumen Endotracheal Tube Intubation: A Retrospective Analysis [J].
Purugganan, Ronaldo V. ;
Jackson, Timothy A. ;
Heir, Jagtar Singh ;
Wang, Hao ;
Cata, Juan P. .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2012, 26 (05) :845-848
[28]   The margin of safety of a left double-lumen tracheobronchial tube depends on the length of the bronchial cuff and tip [J].
Partridge, L. ;
Russell, W. J. .
ANAESTHESIA AND INTENSIVE CARE, 2006, 34 (05) :618-620
[29]   Recent advances in double-lumen tube malposition in thoracic surgery: A bibliometric analysis and narrative literature review [J].
Zhang, Xi ;
Wang, Dong-Xu ;
Wei, Jing-Qiu ;
Liu, He ;
Hu, Si-Ping .
FRONTIERS IN MEDICINE, 2022, 9
[30]   Utilization of an Endobronchial Blocker Through a Double-Lumen Tube as Rescue for Inadequate One-Lung Ventilation [J].
Tang, Jonathan E. ;
Roessner, Colton T. ;
Stocum, Robert D. ;
Stein, Erica J. ;
Essandoh, Michael K. ;
D'Souza, Desmond M. .
SEMINARS IN CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2024, 28 (01) :50-53