Failed extubation of a double-lumen tube requiring a cricoid split

被引:3
|
作者
Probert, DJ [1 ]
Hardman, JG [1 ]
机构
[1] Royal Brisbane Hosp, Dept Anaesthesia & Perioperat Med, Brisbane, Qld 4029, Australia
关键词
airway : difficult extubation; double-lumen tube; cricoid split;
D O I
10.1177/0310057X0303100517
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Following a five-hour procedure, it was not possible to remove a double-lumen endobronchial tube that had been placed to facilitate the removal of a massive spleen from a 45-year-old female. The tube had been passed easily at the start of surgery, but was firmly stuck at the level of the cricoid at the end of surgery. Surgical removal of the tube by a cricoid split was required 48 hours later Consideration of previous airway manipulations, careful choice of airway devices and regular checks of airway patency around tracheal tubes during lengthy procedures may prevent similar events in the future.
引用
收藏
页码:584 / 587
页数:4
相关论文
共 50 条
  • [1] Introduction of a modified double-lumen tube
    Shinsuke Hamaguchi
    Journal of Anesthesia, 2018, 32 : 652 - 652
  • [2] Introduction of a modified double-lumen tube
    Shinsuke, Hamaguchi
    JOURNAL OF ANESTHESIA, 2018, 32 (04) : 652 - 652
  • [3] The Combination of Diameters of Cricoid Ring and Left Main Bronchus for Selecting the "Best Fit" Double-Lumen Tube
    Liu Shiqing
    Qi Wenxu
    Zhang Jin
    Dong Youjing
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2018, 32 (02) : 869 - 876
  • [4] Videolaryngoscopy: Benefits for double-lumen tube insertion
    Cordier, P. -Y.
    Ponchel, C.
    Ausset, P.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2012, 31 (12): : 980 - 982
  • [5] Con: A Bronchial Blocker Is Not a Substitute for a Double-Lumen Endobronchial Tube
    Brodsky, Jay B.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2015, 29 (01) : 237 - 239
  • [6] BRONCHIAL TRAUMA SECONDARY TO INTUBATION WITH A PVC DOUBLE-LUMEN TUBE
    PEDEN, CJ
    SMITH, RB
    GALIZIA, EJ
    JOURNAL OF THE ROYAL SOCIETY OF MEDICINE, 1992, 85 (11) : 705 - 706
  • [7] Usefulness of the Airtraq DL™ videolaryngoscope for placing a double-lumen tube
    Chastel, Brigitte
    Perrier, Virginie
    Germain, Arnaud
    Seramondi, Regis
    Roze, Hadrien
    Ouattara, Alexandre
    ANAESTHESIA CRITICAL CARE & PAIN MEDICINE, 2015, 34 (02) : 89 - 93
  • [8] Iatrogenic Tracheal Rupture during Intubation with a Double-Lumen Tube
    Tezel, C.
    Okur, E.
    Baysungur, V.
    THORACIC AND CARDIOVASCULAR SURGEON, 2010, 58 (01): : 54 - U4
  • [9] Difficult double-lumen tube placement due to laryngeal web
    Schmidt, M. H.
    Riley, R. H.
    Hee, G. Y. K.
    ANAESTHESIA AND INTENSIVE CARE, 2010, 38 (01) : 194 - 196
  • [10] A randomized trial to assess the effect of cricoid displacing maneuver on the success rate of blind placement of double-lumen tube and Univent bronchial blocker
    Xu, Zhao
    Yu, Hong
    Luo, Yuting
    Ye, Yuancai
    Zhou, Cheng
    Liang, Peng
    ANNALS OF PALLIATIVE MEDICINE, 2021, 10 (02) : 1976 - 1984