Endovascular Stent-Graft Repair of Late Pseudoaneurysms After Surgery for Aortic Coarctation

被引:11
|
作者
Zipfel, Burkhart [1 ]
Ewert, Peter
Buz, Semih
Abd El Al, Alaa
Hammerschmidt, Robert
Hetzer, Roland
机构
[1] Deutsch Herzzentrum Berlin, Dept Cardiothorac & Vasc Surg, D-13353 Berlin, Germany
关键词
SURGICAL REPAIR; AORTOBRONCHIAL FISTULA; THORACIC AORTA; ANEURYSMS; AORTOPLASTY; MANAGEMENT;
D O I
10.1016/j.athoracsur.2010.08.053
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. We analyzed the potential of endovascular stent grafts to treat late aortic pseudoaneurysms after coarctation repair. Methods. Eight patients (7 male; age 28 to 58, mean 43 years) presented with aortic pseudoaneurysms after primary repair performed at the age of 5 to 27 (mean 12) years; 2 patients had rupture with hemorrhagic shock. The mean interval between the procedures was 31 (19 to 42) years; one patient had 3 previous operations. This subset represents 2.2% of our overall experience in thoracic endovascular repair (n = 368). Thoracic endografts were implanted using the transfemoral technique. Custom-made reverse tapered stent grafts were used in 4 cases. The left subclavian artery (LSA) was covered in 5 patients. Protective transposition of the left subclavian artery was performed in 4 patients. Results. Hospital mortality was 12.5%; 1 patient died from secondary rupture after emergency repair. Primary complete exclusion of the aneurysm was achieved in 6 patients. Secondary exclusion after implantation of a second stent graft was successful in the second rupture patient. No endoleak was present at discharge. All discharged patients are alive after 8 to 63 (mean 36) months. Follow-up computed tomography or transesophageal echocardiography revealed no secondary endoleaks or late expansion. The pseudoaneurysms had shrunk completely in 3 patients, were reduced in size in 2 patients, and remained unchanged in 2 patients. No late secondary interventions were noted. Conclusions. Single piece, reversed, tapered stent grafts adapt better to the special anatomy of the hypoplastic aortic arch. Midterm results are excellent; complete shrinkage in 50% is remarkable. However, the long-term behavior of these implants in young patients requires further evaluation and surveillance. (Ann Thorac Surg 2011;91:85-91) (C) 2011 by The Society of Thoracic Surgeons
引用
收藏
页码:85 / 91
页数:7
相关论文
共 50 条
  • [31] Endovascular Stent-Graft Repair of True and False Aneurysms of the Splenic Artery
    Borghese, Ottavia
    Pisani, Angelo
    Luparelli, Antonio
    Sica, Simona
    Minelli, Fabrizio
    Donati, Tommaso
    Tshomba, Yamume
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (10)
  • [32] Retrograde type A aortic dissections after endovascular stent-graft placement for type B dissection
    Bellos, J. K.
    Petrosyan, A.
    Abdulamit, T.
    Trastour, J. -C.
    Bergeron, P.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2010, 51 (01) : 85 - 93
  • [33] Endovascular Stent-Graft Repair of a Symptomatic Superior Mesenteric Artery Aneurysm
    Schweigert, Michael
    Adamus, Ralf
    Stadlhuber, Rudolf J.
    Stein, Hubert J.
    ANNALS OF VASCULAR SURGERY, 2011, 25 (06) : 841.e5 - 841.e8
  • [34] Stent-graft repair for blunt traumatic aortic injury: functional and survival outcomes
    Gonzalez Sanchez, S.
    Martin Conejero, A.
    Monux Ducaju, G.
    Martinez Lopez, I.
    Hernando Rydings, M.
    Serrano Hernando, F. J.
    INTERNATIONAL ANGIOLOGY, 2013, 32 (01) : 61 - 66
  • [35] Endovascular treatment of descending thoracic aortic aneurysms with the EndoFit stent-graft
    Saratzis, N.
    Saratzis, Athanasios
    Melas, N.
    Ginis, G.
    Lioupis, A.
    Lykopoulos, D.
    Lazaridis, J.
    Kiskinis, Dimitrios
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (02) : 177 - 181
  • [36] Late morbidity after repair of aortic coarctation
    Pedersen, Thais Almeida Lins
    DANISH MEDICAL JOURNAL, 2012, 59 (04):
  • [37] Endovascular Stent-Graft Repair of the Ascending Aorta: Assessment of a Specific Novel Stent-Graft Design in Phantom, Cadaveric, and Clinical Application
    Hauck, Sven R.
    Kupferthaler, Alexander
    Stelzmueller, Marlies
    Eilenberg, Wolf
    Ehrlich, Marek
    Neumayer, Christoph
    Wolf, Florian
    Loewe, Christian
    Funovics, Martin A.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2021, 44 (09) : 1448 - 1455
  • [38] Late perforation of a thoracic aortic Dacron graft by a metallic stent-graft component
    Cosin, Octavio
    Rousseau, Herve
    Otal, Phillipe
    Cron, Christoff
    Chabbert, Valerie
    Joffre, Francis
    JOURNAL OF ENDOVASCULAR THERAPY, 2006, 13 (05) : 676 - 680
  • [39] Endovascular Treatment of Late Thoracic Aortic Aneurysms after Surgical Repair of Congenital Aortic Coarctation in Childhood
    Juszkat, Robert
    Perek, Bartlomiej
    Zabicki, Bartosz
    Trojnarska, Olga
    Jemielity, Marek
    Staniszewski, Ryszard
    Smoczyk, Wieslaw
    Pukacki, Fryderyk
    PLOS ONE, 2013, 8 (12):
  • [40] Endovascular occlusion of an aortic coarctation after thoracic endovascular aortic repair of an anastomotic aneurysm
    Covic, Tea
    Leone, Nicola
    Gennai, Stefano
    Silingardi, Roberto
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2021, 27 (04) : 567 - 569