Endovascular Stent-Graft Repair of Late Pseudoaneurysms After Surgery for Aortic Coarctation

被引:11
|
作者
Zipfel, Burkhart [1 ]
Ewert, Peter
Buz, Semih
Abd El Al, Alaa
Hammerschmidt, Robert
Hetzer, Roland
机构
[1] Deutsch Herzzentrum Berlin, Dept Cardiothorac & Vasc Surg, D-13353 Berlin, Germany
关键词
SURGICAL REPAIR; AORTOBRONCHIAL FISTULA; THORACIC AORTA; ANEURYSMS; AORTOPLASTY; MANAGEMENT;
D O I
10.1016/j.athoracsur.2010.08.053
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. We analyzed the potential of endovascular stent grafts to treat late aortic pseudoaneurysms after coarctation repair. Methods. Eight patients (7 male; age 28 to 58, mean 43 years) presented with aortic pseudoaneurysms after primary repair performed at the age of 5 to 27 (mean 12) years; 2 patients had rupture with hemorrhagic shock. The mean interval between the procedures was 31 (19 to 42) years; one patient had 3 previous operations. This subset represents 2.2% of our overall experience in thoracic endovascular repair (n = 368). Thoracic endografts were implanted using the transfemoral technique. Custom-made reverse tapered stent grafts were used in 4 cases. The left subclavian artery (LSA) was covered in 5 patients. Protective transposition of the left subclavian artery was performed in 4 patients. Results. Hospital mortality was 12.5%; 1 patient died from secondary rupture after emergency repair. Primary complete exclusion of the aneurysm was achieved in 6 patients. Secondary exclusion after implantation of a second stent graft was successful in the second rupture patient. No endoleak was present at discharge. All discharged patients are alive after 8 to 63 (mean 36) months. Follow-up computed tomography or transesophageal echocardiography revealed no secondary endoleaks or late expansion. The pseudoaneurysms had shrunk completely in 3 patients, were reduced in size in 2 patients, and remained unchanged in 2 patients. No late secondary interventions were noted. Conclusions. Single piece, reversed, tapered stent grafts adapt better to the special anatomy of the hypoplastic aortic arch. Midterm results are excellent; complete shrinkage in 50% is remarkable. However, the long-term behavior of these implants in young patients requires further evaluation and surveillance. (Ann Thorac Surg 2011;91:85-91) (C) 2011 by The Society of Thoracic Surgeons
引用
收藏
页码:85 / 91
页数:7
相关论文
共 50 条
  • [21] Endovascular stent-graft repair of transected left subclavian artery
    Jinadasa, Sayuri P.
    Hall, Michael R.
    Feliciano, David, V
    TRAUMA SURGERY & ACUTE CARE OPEN, 2021, 6 (01)
  • [22] Fever after Percutaneous Endovascular Stent-graft in Type B Acute Aortic Dissection
    Yu, Dan
    Yan, Jiangtao
    Zeng, Hesong
    INTERNAL MEDICINE, 2011, 50 (19) : 2095 - 2098
  • [23] Fenestrated Stent-Graft Facilitates Emergency Endovascular Therapy for Blunt Aortic Injury
    Kurimoto, Yoshihiko
    Asai, Yasufumi
    Nara, Satoshi
    Mori, Kazuhisa
    Hase, Mamoru
    Ohori, Syunsuke
    Ito, Toshiro
    Baba, Toshio
    Kawaharada, Nobuyoshi
    Higami, Tetsuya
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (04): : 974 - 978
  • [24] Endovascular Repair of Aortic Isthmus Coarctation With a Self-Expanding Covered Stent
    Oberhuber, Alexander
    Muehling, Bernd M.
    Orend, Karl-Heinz
    Schelzig, Hubert
    ANNALS OF VASCULAR SURGERY, 2012, 26 (04) : 573.e5 - 573.e7
  • [25] Comparison of a percutaneous separate stent endograft and a conventional thoracic stent-graft for endovascular repair of type B aortic dissection
    Park, S
    Min, PK
    Joung, B
    Ko, YG
    Choi, D
    Jang, Y
    Lee, DY
    Chang, BC
    Shim, WH
    JOURNAL OF ENDOVASCULAR THERAPY, 2004, 11 (04) : 378 - 384
  • [26] Safety and Feasibility Study of a Novel Stent-Graft for Thoracic Endovascular Aortic Repair: a Canine Model Experiment
    Yang, Fan
    Qiu, Jiehua
    Fu, Zeliang
    Qiu, Yuchen
    Luo, Junrong
    Xiao, Qingyang
    Cao, Huabin
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2017, 32 (05) : 401 - 407
  • [27] Impact of gender on the outcome of endovascular aortic aneurysm repair using the zenith stent-graft: Midterm results
    Hugl, Beate
    Hakaim, Albert G.
    Biebl, Matthias
    Oldenburg, W. Andrew
    McKinney, J. Mark
    Nolte, Lorraine A.
    Greenberg, Roy K.
    Chuter, Timothy A. M.
    JOURNAL OF ENDOVASCULAR THERAPY, 2007, 14 (02) : 115 - 121
  • [28] How to Occlude a Side Branch on a Branched Stent-Graft During an Endovascular Thoracoabdominal Aortic Aneurysm Repair
    Ferreira, Marcelo
    Monteiro, Marcelo
    Lanziotti, Luiz
    JOURNAL OF ENDOVASCULAR THERAPY, 2009, 16 (04) : 454 - 456
  • [29] Endovascular Treatment of Descending Thoracic Aortic Aneurysms with the EndoFit Stent-Graft
    N. Saratzis
    Athanasios Saratzis
    N. Melas
    G. Ginis
    A. Lioupis
    D. Lykopoulos
    J. Lazaridis
    Dimitrios Kiskinis
    CardioVascular and Interventional Radiology, 2007, 30
  • [30] False aneurysms at both ends of a descending thoracic aortic stent-graft: Complication after endovascular repair of a penetrating atherosclerotic ulcer
    Chen, FH
    Shim, WH
    Chang, BC
    Park, SJ
    Won, JY
    Lee, DY
    JOURNAL OF ENDOVASCULAR THERAPY, 2003, 10 (02) : 249 - 253