Endovascular Stent-Graft Repair of Late Pseudoaneurysms After Surgery for Aortic Coarctation

被引:11
|
作者
Zipfel, Burkhart [1 ]
Ewert, Peter
Buz, Semih
Abd El Al, Alaa
Hammerschmidt, Robert
Hetzer, Roland
机构
[1] Deutsch Herzzentrum Berlin, Dept Cardiothorac & Vasc Surg, D-13353 Berlin, Germany
关键词
SURGICAL REPAIR; AORTOBRONCHIAL FISTULA; THORACIC AORTA; ANEURYSMS; AORTOPLASTY; MANAGEMENT;
D O I
10.1016/j.athoracsur.2010.08.053
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. We analyzed the potential of endovascular stent grafts to treat late aortic pseudoaneurysms after coarctation repair. Methods. Eight patients (7 male; age 28 to 58, mean 43 years) presented with aortic pseudoaneurysms after primary repair performed at the age of 5 to 27 (mean 12) years; 2 patients had rupture with hemorrhagic shock. The mean interval between the procedures was 31 (19 to 42) years; one patient had 3 previous operations. This subset represents 2.2% of our overall experience in thoracic endovascular repair (n = 368). Thoracic endografts were implanted using the transfemoral technique. Custom-made reverse tapered stent grafts were used in 4 cases. The left subclavian artery (LSA) was covered in 5 patients. Protective transposition of the left subclavian artery was performed in 4 patients. Results. Hospital mortality was 12.5%; 1 patient died from secondary rupture after emergency repair. Primary complete exclusion of the aneurysm was achieved in 6 patients. Secondary exclusion after implantation of a second stent graft was successful in the second rupture patient. No endoleak was present at discharge. All discharged patients are alive after 8 to 63 (mean 36) months. Follow-up computed tomography or transesophageal echocardiography revealed no secondary endoleaks or late expansion. The pseudoaneurysms had shrunk completely in 3 patients, were reduced in size in 2 patients, and remained unchanged in 2 patients. No late secondary interventions were noted. Conclusions. Single piece, reversed, tapered stent grafts adapt better to the special anatomy of the hypoplastic aortic arch. Midterm results are excellent; complete shrinkage in 50% is remarkable. However, the long-term behavior of these implants in young patients requires further evaluation and surveillance. (Ann Thorac Surg 2011;91:85-91) (C) 2011 by The Society of Thoracic Surgeons
引用
收藏
页码:85 / 91
页数:7
相关论文
共 50 条
  • [1] Endovascular repair of pseudoaneurysms after open surgery for aortic coarctation
    Kotelis, Drosos
    Bischoff, Moritz S.
    Rengier, Fabian
    Ruhparwar, Arjang
    Gorenflo, Matthias
    Boeckler, Dittmar
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2016, 22 (01) : 26 - 31
  • [2] Endovascular Repair of Aortic Coarctation Pseudoaneurysm Using an Off-Label "Hourglass" Stent-Graft Configuration
    Erben, Young
    Oderich, Gustavo S.
    Duncan, Audra A.
    JOURNAL OF ENDOVASCULAR THERAPY, 2015, 22 (03) : 460 - 465
  • [3] Endovascular Treatment for Pseudoaneurysms After the Surgical Repair of Aortic Coarctation
    Alkashkari, Wail
    Al-Husayni, Faisal
    Alfouti, Mawaddah
    Alsofyani, Rahaf
    Alfawaz, Sarah
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (07)
  • [4] New-generation stent grafts for endovascular management of thoracic pseudoaneurysms after aortic coarctation repair
    Perera, Anisha H.
    Rudarakanchana, Nung
    Hamady, Mohamad
    Kashef, Elika
    Mireskandari, Maziar
    Uebing, Anselm
    Cheshire, Nicholas J.
    Bicknell, Colin D.
    JOURNAL OF VASCULAR SURGERY, 2014, 60 (02) : 330 - 336
  • [5] Endovascular Stent-graft Treatment for Stanford Type A Aortic Dissection
    Ye, C.
    Chang, G.
    Li, S.
    Hu, Z.
    Yao, C.
    Chen, W.
    Li, X.
    Wang, S.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2011, 42 (06) : 787 - 794
  • [6] Homemade fenestrated stent-graft for thoracic endovascular aortic repair of zone 2 aortic lesions
    Canaud, Ludovic
    Morishita, Kiyofumi
    Gandet, Thomas
    Sfeir, Julien
    Bommart, Sebastien
    Alric, Pierre
    Mandelli, Marcello
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (02) : 488 - 493
  • [7] Type A dissection following endovascular thoracic aortic stent-graft repair
    Neuhauser, B
    Czermak, BV
    Fish, J
    Perkmann, R
    Jaschke, W
    Chemelli, A
    Fraedrich, G
    JOURNAL OF ENDOVASCULAR THERAPY, 2005, 12 (01) : 74 - 81
  • [8] Case report: Endovascular stent-graft repair of aortic penetrating trauma, literature review, and case report
    Bayona, Juan Gabriel
    Chaves, Carlos Eduardo Rey
    Rodriguez, Oscar Geovanny Hernandez
    Baron, Vladimir
    Fajardo, Ernesto
    Posada, Eduardo
    FRONTIERS IN SURGERY, 2023, 10
  • [9] Aortic aneurysms' treatment with endovascular stent-graft
    Rahman, Ali
    Colak, Mehmet Cengiz
    Ozdemir, Huseyin
    Ozguler, Murat
    Cil, Barbaros E.
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 17 (03): : 167 - 172
  • [10] Endovascular Stent-Graft Repair of Aortobronchial Fistulas
    Kawaharada, Nobuyoshi
    Kurimoto, Yoshihiko
    Ito, Toshiro
    Uehara, Mayuko
    Maeda, Toshiyuki
    Koyanagi, Tetsuya
    Muraki, Satoshi
    Watanabe, Atsushi
    Higami, Tetsuya
    ANNALS OF THORACIC SURGERY, 2012, 94 (02) : 524 - 529