Neutron detection with Gd/CdTe semiconductor detector

被引:1
|
作者
Miyake, Aki [1 ]
Nishioka, Takahiro [1 ]
Singh, Shailendra [1 ]
Morii, Hisashi [1 ]
Neo, Yoichiro [1 ]
Mimura, Hidenori [1 ]
Aoki, Toru [1 ]
机构
[1] Shizuoka Univ, Elect Res Inst, Naka Ku, Hamamatsu, Shizuoka 4328011, Japan
来源
HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XII | 2010年 / 7805卷
关键词
thermal neutron; detector; CdTe;
D O I
10.1117/12.862505
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cadmium telluride (CdTe) detector has been used to detect thermal neutrons; along with gadolinium (Gd) used as a neutron converter. Simulation results show that the appropriate thickness of Gd film for CdTe detector is 25 mu m. The Gd/CdTe detector shows the 80 keV, 89 keV and 182 keV gamma ray emission peaks from Gd-155(n, gamma)Gd-156 and Gd-157(n, gamma)Gd-158 reactions.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A CdTe detector with a Gd converter for thermal neutron detection
    Miyake, Aki
    Nishioka, Takahiro
    Singh, Shailendra
    Morii, Hisashi
    Mimura, Hidenori
    Aoki, Toru
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 654 (01): : 390 - 393
  • [2] Thermal neutron detection by CdTe detector
    Nishioka, Takahiro
    Miyake, Aki
    Singh, Shailendra
    Morii, Hisashi
    Mimura, Hidenori
    Aoki, Toru
    INTER ACADEMIA 2010: GLOBAL RESEARCH AND EDUCATION, 2011, 222 : 146 - +
  • [3] Prompt gamma and neutron detection in BNCT utilizing a CdTe detector
    Winkler, Alexander
    Koivunoro, Hanna
    Reijonen, Vappu
    Auterinen, Iiro
    Savolainen, Sauli
    APPLIED RADIATION AND ISOTOPES, 2015, 106 : 139 - 144
  • [4] SPECTRAL CT WITH A CDTE SEMICONDUCTOR DETECTOR
    Schulze, J.
    Koenig, T.
    Zuber, M.
    Zwerger, A.
    Fauler, A.
    Nill, S.
    Fiederle, M.
    Oelfke, U.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S436 - S436
  • [5] Development of a CdTe thermal neutron detector for neutron imaging
    Miyake, Aki
    Nishioka, Takahiro
    Singh, Shailendra
    Morii, Hisashi
    Mimura, Hidenori
    Aoki, Toru
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 677 : 41 - 44
  • [6] Detection of Contrast Agents with a CdTe Semiconductor Detector Intended for Small Animal Imaging
    Schulze, J.
    Koenig, T.
    Zuber, M.
    Zwerger, A.
    Fauler, A.
    Nill, S.
    Fiederle, M.
    Oelfke, U.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [7] Semiconductor Thermal Neutron Detector
    Aoki, Toru
    Miyake, Aki
    Nakano, Takayuki
    Koike, Akifumi
    Morii, Hisashi
    Mimura, Hidenori
    MAKARA JOURNAL OF TECHNOLOGY, 2013, 17 (03): : 133 - 137
  • [8] Perforated semiconductor neutron detector modules for detection of spontaneous fission neutrons
    McGregor, Douglas S.
    Bellinger, Steven L.
    Bruno, David
    Cowley, Shawn
    Elazegui, Melanie
    McNeil, Walter J.
    Patterson, Eric
    Unruh, Troy
    Solomon, Clell J.
    Shultis, J. Kenneth
    Rice, Blake B.
    2007 IEEE CONFERENCE ON TECHNOLOGIES FOR HOMELAND SECURITY: ENHANCING CRITICAL INFRASTRUCTURE DEPENDABILITY, 2007, : 162 - +
  • [9] SEMICONDUCTOR DETECTOR AS A FAST NEUTRON SPECTROMETER
    MILLER, RG
    KAVANAGH, RW
    NUCLEAR INSTRUMENTS & METHODS, 1967, 48 (01): : 13 - &
  • [10] Examination of CdTe semiconductor detector for nuclear medicines.
    Nakamura, N
    Takayama, T
    Motomura, N
    Mori, I
    Ohno, R
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 176P - 177P