Single-Pole Ground Fault Location Method for Multi-terminal Flexible DC Transmission Lines Based on LSSVM

被引:0
|
作者
Wei, Ke [1 ]
Lan, Sheng [1 ]
Li, Zhichuan [1 ]
机构
[1] Fuzhou Univ, Coll Elect Engn & Automat, Fuzhou, Peoples R China
来源
2022 12TH INTERNATIONAL CONFERENCE ON POWER AND ENERGY SYSTEMS, ICPES | 2022年
关键词
multi-terminal flexible DC power grid; fault location; Pearson correlation coefficient; least squares support vector machine;
D O I
10.1109/ICPES56491.2022.10072468
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In order to ensure the safe and stable operation of multi-terminal flexible DC system and improve the accuracy of single-pole grounding fault location of transmission lines. This paper proposes a single-pole grounding fault location method based on Least Squares Support Vector Machine (LSSVM). When the ground fault occurs, the line mode voltage of different sections in series is combined with the classification mechanism of least squares support vector machine to identify the fault section. Then, the frequency domain characteristics of the line mode voltage in this section are extracted by wavelet packet decomposition combined with Pearson correlation coefficient, and the LSSVM model is established based on the characteristic results to realize fault location. The sparrow search algorithm is used to optimize the parameters of LSSVM model. This paper established +/- 500kV four-terminal flexible DC simulation model for testing. The results show that the method has good anti-transition resistance ability, and the location error is within 0.37 km at the sampling frequency of 50 kHz.
引用
收藏
页码:214 / 218
页数:5
相关论文
共 50 条
  • [21] DC fault location in multi-terminal DC distribution network based on voltage similar triangle principle
    Yang, Yachao
    Huang, Chun
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 184
  • [22] A single terminal fault location method for a DC transmission line based on circuit breaker reclosing
    Zhao G.
    Jia K.
    Chen J.
    Chen M.
    Bi T.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2021, 49 (07): : 48 - 56
  • [23] Decision tree aided travelling wave based fault section identification and location scheme for multi-terminal transmission lines
    Chaitanya, B. K.
    Yadav, Anamika
    MEASUREMENT, 2019, 135 : 312 - 322
  • [24] Fault location scheme for a multi-terminal transmission line based on current traveling waves
    Zhu Yongli
    Fan Xinqiao
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 53 : 367 - 374
  • [25] Fault Location for Multi-Terminal Tapped Lines using Synchronized Measurements
    George, Neethu
    Naidu, O. D.
    Srivastava, Sachin
    Sai, A. V. S. S. R.
    2018 IEEE RECENT ADVANCES IN INTELLIGENT COMPUTATIONAL SYSTEMS (RAICS), 2018, : 153 - 158
  • [26] Travelling Waves Based Fault Location Method for Overhead-Cable Hybrid Multi-Terminal Transmission Line
    Yang Yongxing
    Nie Dezhi
    Zhang Jianjun
    Zheng Haocong
    Zhang Jiexiong
    Huang Zhizeng
    Luo Zhengcheng
    Li Haifeng
    2024 IEEE 2ND INTERNATIONAL CONFERENCE ON POWER SCIENCE AND TECHNOLOGY, ICPST 2024, 2024, : 1058 - 1063
  • [27] Negative-Sequence Network Based Fault Location Scheme for Double-Circuit Multi-Terminal Transmission Lines
    Ghorbani, Amir
    Mehrjerdi, Hasan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2019, 34 (03) : 1109 - 1117
  • [28] A fault distance interval based single terminal traveling wave fault location method for hybrid transmission lines
    Niu, Rui
    Liang, Jun
    Yun, Zhihao
    Zhang, Feng
    Dianwang Jishu/Power System Technology, 2015, 39 (01): : 156 - 163
  • [29] Fault location technique for multi-terminal DC-microgrid based Gaussian process regression
    Elmadawy, Mohamed
    Ghanem, Abdelhady
    Deng, Fujin
    Abulanwar, Sayed
    Shahin, Ahmed
    ELECTRIC POWER SYSTEMS RESEARCH, 2025, 242
  • [30] Fault location on multi-terminal DC systems using synchronized current measurements
    Azizi, Sadegh
    Afsharnia, Saeed
    Sanaye-Pasand, Majid
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 63 : 779 - 786