Removal of NOx and SO2 from air excited by streamer corona:: Experimental results and modeling

被引:18
作者
Amirov, RH
Chae, JO
Dessiaterik, YN
Filimonova, EA
Zhelezniak, MB
机构
[1] Russian Acad Sci, Inst High Temp, Moscow 127412, Russia
[2] Inha Univ, Combust Lab, Dept Mech, Nam Gu, Inchon, South Korea
来源
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS | 1998年 / 37卷 / 6A期
关键词
SO2/NOx removal; pulsed corona discharge; streamer; modeling of gas reaction kinetics;
D O I
10.1143/JJAP.37.3521
中图分类号
O59 [应用物理学];
学科分类号
摘要
The effect of pulse corona discharge on NOx and SO2 concentrations in air has been studied. The initial concentrations and ammonia addition have been shown to influence the removal efficiency. An SO2 removal efficiency of 96% and an NO removal efficiency of 70% in pulse corona have been achieved with ammonia addition, for initial SO2 and NO concentrations of 480 ppm and 230 ppm, respectively. A numerical model for NO and SO2 conversion in homogeneous gas flow has been developed. The spatial nonuniformity of gas parameters associated with the existence of many streamer channels in a discharge chamber is taken into account. A comparison between experiments and modeling shows that SO2 removal is mainly determined by OH and O-3(-). NO conversion is achieved the reactions of O-3, OH and N.
引用
收藏
页码:3521 / 3529
页数:9