Dose Reduction and Image Quality in Photon-counting Detector High-resolution Computed Tomography of the Chest Routine Clinical Data

被引:47
作者
Graafen, Dirk [1 ]
Emrich, Tilman [3 ,4 ]
Halfmann, Moritz C. [1 ,3 ]
Mildenberger, Peter [1 ]
Dueber, Christoph [1 ]
Yang, Yang [1 ]
Othman, Ahmed E. [2 ]
O' Doherty, Jim [5 ]
Mueller, Lukas [1 ]
Kloeckner, Roman [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Diagnost & Intervent Radiol, Langenbeckst 1, D-55131 Mainz, Germany
[2] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Neuroradiol, Mainz, Germany
[3] German Ctr Cardiovasc Res DZHK, Partner Site Rhine Main, Mainz, Germany
[4] Med Univ South Carolina, Div Cardiovasc Imaging, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
[5] Siemens Med Solut, Malvern, PA USA
关键词
high-resolution computed tomography; photon-counting detector; tin filtration; dose reduction; CT; FEASIBILITY;
D O I
10.1097/RTI.0000000000000661
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Photon-counting detector computed tomography (PCD-CT) has the potential to significantly improve CT imaging in many ways including, but not limited to, low-dose high-resolution CT (HRCT) of the lung. The aim of this study was to perform an intrapatient comparison of the radiation dose and image quality of PCD-CT compared with conventional energy-integrating detector CT (EID-CT). Methods: A total of 32 consecutive patients with available PCD-CT and EID-CT HRCT scans were included in the final analysis. The CT dose index (CTDIvol) was extracted from patient dose reports. Qualitative image analysis comprised the lung parenchyma and mediastinal structures and was assessed by 3 readers using a 5-point Likert scale. Quantitative image analysis included assessment of noise and signal-to-noise ratio in the lung parenchyma, trachea, aorta, muscle, and background. Results: The mean CTDIvol was 2.0 times higher in the conventional EID-CT scans (1.8 +/- 0.5 mGy) compared with PCD-CT (0.9 +/- 0.5 mGy, P<0.001). The overall image quality was rated significantly better by all 3 raters (P<0.001) in the PCD-CT relative to the EID-CT. Quantitative analysis showed no significant differences in noise and signal-to-noise ratio in the lung parenchyma between PCD-CT and EID-CT. Conclusion: Compared with conventional EID-CT scans, PCD-CT demonstrated similar or better objective and subjective image quality at significantly reduced dose levels in an intrapatient comparison. These results and their effect on clinical decision-making should be further investigated in prospective studies.
引用
收藏
页码:315 / 322
页数:8
相关论文
共 16 条
  • [1] Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length Product
    Deak, Paul D.
    Smal, Yulia
    Kalender, Willi A.
    [J]. RADIOLOGY, 2010, 257 (01) : 158 - 166
  • [2] Ultralow-Dose Chest Computed Tomography for Pulmonary Nodule Detection First Performance Evaluation of Single Energy Scanning With Spectral Shaping
    Gordic, Sonja
    Morsbach, Fabian
    Schmidt, Bernhard
    Allmendinger, Thomas
    Flohr, Thomas
    Husarik, Daniela
    Baumueller, Stephan
    Raupach, Rainer
    Stolzmann, Paul
    Leschka, Sebastian
    Frauenfelder, Thomas
    Alkadhi, Hatem
    [J]. INVESTIGATIVE RADIOLOGY, 2014, 49 (07) : 465 - 473
  • [3] Unenhanced third-generation dual-source chest CT using a tin filter for spectral shaping at 100 kVp
    Haubenreisser, Holger
    Meyer, Mathias
    Sudarski, Sonja
    Allmendinger, Thomas
    Schoenberg, Stefan O.
    Henzler, Thomas
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (08) : 1608 - 1613
  • [4] First Performance Evaluation of an Artificial Intelligence-Based Computer-Aided Detection System for Pulmonary Nodule Evaluation in Dual-Source Photon-Counting Detector CT at Different Low-Dose Levels
    Jungblut, Lisa
    Bluthgen, Christian
    Polacin, Malgorzata
    Messerli, Michael
    Schmidt, Bernhard
    Euler, Andre
    Alkadhi, Hatem
    Frauenfelder, Thomas
    Martini, Katharina
    [J]. INVESTIGATIVE RADIOLOGY, 2022, 57 (02) : 108 - 114
  • [5] Ultralow-dose CT with tin filtration for detection of solid and sub solid pulmonary nodules: a phantom study
    Martini, Katharina
    Higashigaito, Kai
    Barth, Borna K.
    Baumueller, Stephan
    Alkadhi, Hatem
    Frauenfelder, Thomas
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1056)
  • [6] Approaches to ultra-low radiation dose coronary artery calcium scoring based on 3rd generation dual-source CT: A phantom study
    McQuiston, Andrew D.
    Muscogiuri, Giuseppe
    Schoepf, U. Joseph
    Meinel, Felix G.
    Canstein, Christian
    Varga-Szemes, Akos
    Cannao, Paola M.
    Wichmann, Julian L.
    Allmendinger, Thomas
    Vliegenthart, Rozemarijn
    De Cecco, Carlo N.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (01) : 39 - 47
  • [7] Feasibility of lung imaging with a large field-of-view spectral photon-counting CT system
    Si-Mohamed, Salim
    Boccalini, Sara
    Rodesch, Pierre-Antoine
    Dessouky, Riham
    Lahoud, Elias
    Broussaud, Thomas
    Sigovan, Monica
    Gamondes, Delphine
    Coulon, Philippe
    Yagil, Yoad
    Boussel, Loic
    Douek, Philippe
    [J]. DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2021, 102 (05) : 305 - 312
  • [8] Spectral Photon-Counting CT Technology in Chest Imaging
    Si-Mohamed, Salim Aymeric
    Miailhes, Jade
    Rodesch, Pierre-Antoine
    Boccalini, Sara
    Lacombe, Hugo
    Leitman, Valerie
    Cottin, Vincent
    Boussel, Loic
    Douek, Philippe
    [J]. JOURNAL OF CLINICAL MEDICINE, 2021, 10 (24)
  • [9] Stoel Berend C, 2008, Proc Am Thorac Soc, V5, P929, DOI 10.1513/pats.200804-039QC
  • [10] Feasibility of Low Dose Lung Cancer Screening with a Whole-Body Photon Counting CT: First Human Results
    Symons, R.
    Cork, T.
    Folio, L.
    Bluemke, D.
    Pourmorteza, A.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3835 - 3835