Marginal Bone Response Around Immediate- and Delayed-Loading Implants Supporting a Locator-Retained Mandibular Overdenture: A Randomized Controlled Study

被引:42
|
作者
Schincaglia, Gian Pietro [1 ,2 ]
Rubin, Satoko [2 ]
Thacker, Sejal [2 ]
Dhingra, Ajay [2 ]
Trombelli, Leonardo [3 ]
Ioannidou, Efie [2 ]
机构
[1] Univ Ferrara, Sch Dent, Oral Implantol, 203 Via Giovecca, I-44100 Ferrara, Italy
[2] Univ Connecticut, Ctr Hlth, Div Periodontol, Farmington, CT USA
[3] Univ Ferrara, Dept Periodontol, 203 Via Giovecca, I-44100 Ferrara, Italy
关键词
immediate loading; overdenture; INSERTION TORQUE; DENTAL IMPLANTS; RADIOGRAPHIC EVALUATION; UNSPLINTED IMPLANTS; FORMATION ADJACENT; PRIMARY STABILITY; SURFACE; BRANEMARK; OSSEOINTEGRATION; EFFICIENCY;
D O I
10.11607/jomi.4118
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Implant-supported mandibular overdentures (OVDs) have been proposed as the gold standard for the treatment of edentulous mandibles. There is limited evidence on the clinical outcomes of immediate loading of two unsplinted implants supporting a mandibular OVD. The purpose of this randomized controlled trial was to evaluate the performance of two unsplinted implants supporting a Locator-retained mandibular OVD over 12 months loaded immediately or after a delay. Materials and Methods: Each patient received two implants 4.0 mm in diameter and 8 to 15 mm long. Locator-retained mandibular OVDs were connected to the implants either immediately (IL) or 3 months postsurgery (DL). The primary response variable was radiographic bone loss (RBL) at 6 and 12 months postsurgery. Implant length, insertion torque, implant failure, prevalence of maintenance visits, and prosthetic complications were also recorded. Results: Thirty participants ( 15 in the IL and 15 in the DL groups) were evaluated at 12 months. The implant cumulative survival rates were 100% and 93% for DL and IL, respectively. The mean RBL from baseline to 1 year was 0.54 (+/- 0.5) mm and 0.25 (+/- 0.5) mm for DL and IL, respectively. A statistically significant difference was observed at 12 months, with less RBL in the IL group. Insertion torque and implant length were not correlated with RBL. Also, no difference in frequency of maintenance visits and prosthetic complications was reported between the groups. Conclusion: Immediate loading of two unsplinted implants supporting a Locator-retained mandibular OVD seems to be a suitable treatment option. Significantly less RBL was observed after 1 year of loading around IL implants than around DL implants. Furthermore, neither implant length nor insertion torque seemed to affect RBL 1 year after surgical placement.
引用
收藏
页码:448 / 458
页数:11
相关论文
共 21 条
  • [1] Marginal bone resorption around immediate and delayed loaded implants supporting a locator-retained mandibular overdenture. A 1-year randomised controlled trial
    Elsyad, M. A.
    Elsaih, E. A.
    Khairallah, A. S.
    JOURNAL OF ORAL REHABILITATION, 2014, 41 (08) : 608 - 618
  • [2] Immediate loading of four interforaminal implants supporting a locator-retained mandibular overdenture in the elderly. Results of a 3-year randomized, controlled, prospective clinical study
    Acham, Stephan
    Rugani, Petra
    Truschnegg, Astrid
    Wildburger, Angelika
    Wegscheider, Walther A.
    Jakse, Norbert
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (05) : 895 - 900
  • [3] Immediate Loading of Unsplinted Implant Retained Mandibular Overdenture: A Randomized Controlled Clinical Study
    Kutkut, Ahmad
    Rezk, Mohamed
    Zephyr, Dominique
    Dawson, Dolphus
    Frazer, Robert
    Al-Sabbagh, Mohanad
    JOURNAL OF ORAL IMPLANTOLOGY, 2019, 45 (05) : 378 - 389
  • [4] Immediate loading of two implants supporting a ball attachment-retained mandibular overdenture: A prospective clinical study
    Marzola, Riccardo
    Scotti, Roberto
    Fazi, Giovanni
    Schincaglia, Gian Pietro
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2007, 9 (03) : 136 - 143
  • [5] Marginal bone loss adjacent to conventional and immediate loaded two implants supporting a ball-retained mandibular overdenture: a 3-year randomized clinical trial
    Elsyad, Moustafa Abdou
    Al-Mahdy, Yasmeen Fathy
    Fouad, Mohammed Mohammed
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (04) : 496 - 503
  • [6] Retrospective evaluation of marginal bone loss around implants in a mandibular locator-retained denture using panoramic radiographic images and finite element analysis: A pilot study
    Alkis, Humeyra Tercanli
    Turker, Nurullah
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (06) : 1199 - 1205
  • [7] Effects of immediate and delayed loading protocols on marginal bone loss around implants in unsplinted mandibular implant-retained overdentures: a systematic review and meta-analysis
    Liu, Wei
    Cai, He
    Zhang, Junjiang
    Wang, Jian
    Sui, Lei
    BMC ORAL HEALTH, 2021, 21 (01)
  • [8] The comparison of marginal bone loss around mandibular overdenture-supporting implants with two different attachment types in a loading period of 36 months
    Bilhan, Hakan
    Mumcu, Emre
    Arat, Selda
    GERODONTOLOGY, 2011, 28 (01) : 49 - 57
  • [9] Effects of immediate and delayed loading protocols on marginal bone loss around implants in unsplinted mandibular implant-retained overdentures: a systematic review and meta-analysis
    Wei Liu
    He Cai
    Junjiang Zhang
    Jian Wang
    Lei Sui
    BMC Oral Health, 21
  • [10] Immediate Loading of Two Implants Supporting a Magnet Attachment-Retained Overdenture: One-Year Clinical Study
    Pae, Ahran
    Kim, Jang-Wook
    Kwon, Kung-Rock
    IMPLANT DENTISTRY, 2010, 19 (05) : 428 - 436