How clean is your scope? A completed audit cycle of the disinfection of nasendoscopes

被引:2
作者
Lakhani, Raj [1 ]
Smithard, Abigail [1 ]
Bleach, Nigel [1 ]
机构
[1] Wexham Pk Hosp, ENT Dept, Slough SL2 4HL, Berks, England
关键词
Disinfection; Nasendoscopes;
D O I
10.1308/003588410X12699663904510
中图分类号
R61 [外科手术学];
学科分类号
摘要
INTRODUCTION Correct disinfection of nasendoscopes is essential to address both the potential iatrogenic transmission of infection and to avoid injury from the chemicals used. MATERIALS AND METHODS Standards-based audit of the disinfection of nasendoscopes against the ENT UK guidelines. Intervention: instructional poster and staff training session. The disinfection process was re-audited one month later. RESULTS A total of 10 sessions and 31 cleaning episodes were audited in the first cycle (C1). A total of 12 sessions and 36 cleaning episodes were re-audited in the second cycle (C2). Clinic set-up results: there was a marked improvement in the checking of the expiry date (C1 = 5/10; C2 = 10/12; P <= 0.001) and recording the date for the solution to be discarded (C1 = 0/10; C2 = 10/12; P <= 0.048). Each cleaning episode results: an improvement in transportation in a 'dirty bag' (C1 = 0/31; C2 = 19/36; P <= 0.001), washing of the scope (C1 = 0/31; C2 = 36/36; P <= 0.001), adequate disinfection time (C1 = 16131; C2 = 33/36; P <= 0.001), rinsing and drying with alcohol swab (C1 = 0/31; C2 = 35/36; P <= 0.001) and placing of the scope in a 'clean bag' for storage (C1 = 0/31; C2 = 35/36; P <= 0.001) was seen after the intervention. CONCLUSIONS The introduction of a poster and training in the disinfection of nasendoscopes proved successful in improving compliance with the published guidelines. These simple measures were simple, cheap and effective to institute. The benefit of improving the disinfection of nasendoscopes to patients, doctors and the organisations that they work in is clear.
引用
收藏
页码:587 / 590
页数:4
相关论文
共 10 条
[1]   The effectiveness of immersion disinfection for flexible fiberoptic laryngoscopes [J].
Bhattacharyya, N ;
Kepnes, LJ .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2004, 130 (06) :681-685
[2]  
*ENT UK, 2005, DEC ENT FIBR SCOP
[3]  
Favero M.S., 1991, DISINFECTION STERILI, P617
[4]   The disinfection of flexible fibre-optic nasendoscopes out-of-hours: confidential telephone survey of ENT units in England [J].
Kanagalingam, J ;
Zainal, A ;
Georgalas, C ;
Tolley, NS .
JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2002, 116 (10) :817-822
[5]   Measuring the Scope and Magnitude of Hospital-Associated Infection in the United States: The Value of Prevalence Surveys [J].
Llata, Eloisa ;
Gaynes, Robert P. ;
Fridkin, Scott .
CLINICAL INFECTIOUS DISEASES, 2009, 48 (10) :1434-1440
[6]   Prevention of disease transmission during flexible laryngoscopy [J].
Muscarella, Lawrence F. .
AMERICAN JOURNAL OF INFECTION CONTROL, 2007, 35 (08) :536-544
[7]  
MUSCARELLA LF, 2005, INFECT CONTROL 0521
[8]   APIC guideline for selection and use of disinfectants [J].
Rutala, WA .
AMERICAN JOURNAL OF INFECTION CONTROL, 1996, 24 (04) :313-342
[9]  
RUTALA WA, 1995, HOSPITAL EPIDEMIOLOG, P913
[10]  
2007, HLTH DEVICES, V36, P352