Analysis and validation of perfluorinated compounds in water, sediment and fish with LC-ESI-MS/MS

被引:2
作者
Kaupmees, Siiri [1 ,2 ]
Rebane, Riin [1 ,2 ]
机构
[1] Estonian Environm Res Ctr, Environm & Analyt Chem Dept, Tallinn, Estonia
[2] Univ Tartu, Inst Chem, Chair Analyt Chem, Tartu, Estonia
关键词
Perfluorinated compounds (PFCs); ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS; MS); ion pair extraction (IPE); large volume injection (LVI); validation; LARGE-VOLUME-INJECTION; WASTE-WATER; PERFLUOROOCTANOIC ACID; LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; WASTEWATERS; SAMPLES; BIOTA; PFOA;
D O I
10.1080/03067319.2017.1356922
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analysis of perfluorinated compounds (PFCs) in environmental matrices is challenging, as the concentrations are generally low, but the risk of contamination is high. Sample preparation is a critical step and it is necessary to minimise the possibility of contamination. In this study, we successfully applied and validated a modified ion pair extraction method to quantify PFCs in sediment and fish samples. A large volume injection method was validated and used to quantify PFCs in different water matrices. Isotope internal standard of every analyte was applied to correct matrix effects. The recoveries of the analytes were 92-106% for water matrix, 93-119% for fish matrix and 86-103% for soil matrix whereas the achieved limit of quantitation values were 1.3-14.9ng/L for water, 0.19-0.28g/kg for fish and 0.14-0.41 for soil samples. Thirty-one surface water, 8 stormwater and 41 sediment samples collected all over Estonia were analysed and 4 (out of 8 analysed) PFCs were found in quantitative amount. The most frequently detected analyte perfluorobutanoic acid (PFBA) was found in 26% of the water samples with a maximum concentration of 137ng/L.
引用
收藏
页码:695 / 709
页数:15
相关论文
共 50 条
  • [1] LC-ESI-MS/MS determination of paclitaxel on dried blood spots
    Rao, R. Nageswara
    Raju, S. Satyanarayana
    Vali, R. Mastan
    Sarma, V. U. M.
    Sankar, G. Girija
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (05) : 616 - 621
  • [2] Analytical considerations on the use of a fruit-specific and representative matrix in pesticide residue analysis by LC-ESI-MS/MS
    Stachniuk, Anna
    Fornal, Emilia
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2013, 11 (07): : 1112 - 1131
  • [3] Determination of ketoacids in drinking water by DNPH derivatization and LC-ESI-MS/MS
    Mao, Yu-qin
    Wang, Xiao-mao
    Tang, Shun
    Yang, Hong-wei
    Xie, Yuefeng F.
    ANALYTICAL METHODS, 2015, 7 (15) : 6207 - 6212
  • [4] Development and Validation of LC-ESI-MS/MS Method for the Determination of Alfuzosin in Human Plasma
    Moustapha, Moustapha E.
    El Gamal, Rania M.
    Kamal, Mehnaz
    JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 76 (11) : 1327 - 1335
  • [5] Development and validation of a rapid LC-ESI-MS/MS method for quantification of fluoxetine and its application to MS binding assays
    Hess, Marielle
    Hoefner, Georg
    Wanner, Klaus Theodor
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (10) : 3505 - 3515
  • [6] Analysis of perfluorinated phosponic acids and perfluorooctane sulfonic acid in water, sludge and sediment by LC-MS/MS
    Esparza, X.
    Moyano, E.
    de Boer, J.
    Galceran, M. T.
    van Leeuwen, S. P. J.
    TALANTA, 2011, 86 : 329 - 336
  • [7] LC-ESI-MS Determination of Flupentixol in Human Plasma
    Zuo, Xiao-Cong
    Zhang, Bi-Kui
    Chen, Ben-Mei
    Liu, Shao-Gang
    Yang, Guo-Ping
    Liu, Shi-Kun
    Liu, Shao-Qian
    Huang, Zhi-Jun
    Yuan, Hong
    CHROMATOGRAPHIA, 2009, 69 (3-4) : 301 - 305
  • [8] A simple, fast and sensitive screening LC-ESI-MS/MS method for antibiotics in fish
    Guidi, Leticia Rocha
    Santos, Flavio Alves
    Ribeiro, Ana Claudia S. R.
    Fernandes, Christian
    Silva, Luiza H. M.
    Gloria, Maria Beatriz A.
    TALANTA, 2017, 163 : 85 - 93
  • [9] Thin-film microextraction coupled to LC-ESI-MS/MS for determination of quaternary ammonium compounds in water samples
    Boyaci, Ezel
    Sparham, Chris
    Pawliszyn, Janusz
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (02) : 409 - 420
  • [10] Recent Advances and Special Considerations for the Analysis of Phosphorylated Peptides by LC-ESI-MS/MS
    Liu, Suya
    Hughes, Chris
    Lajoie, Gilles A.
    CURRENT ANALYTICAL CHEMISTRY, 2012, 8 (01) : 35 - 42