Evaluation of a breast software model for 2D and 3D X-ray imaging studies of the breast

被引:21
作者
Baneva, Yanka [1 ]
Bliznakova, Kristina [2 ]
Cockmartin, Lesley [3 ]
Marinov, Stoyko [2 ]
Buliev, Ivan [2 ]
Mettivier, Giovanni [4 ,5 ]
Bosmans, Hilde [3 ]
Russo, Paolo [4 ,5 ]
Marshall, Nicholas [3 ]
Bliznakov, Zhivko [2 ]
机构
[1] Med Univ Varna, Dept Phys & Biophys, Varna, Bulgaria
[2] Tech Univ Varna, Lab Comp Simulat Med, Varna 9010, Bulgaria
[3] Univ Hosp Leuven, Dept Radiol, Med Imaging Res Ctr, Herestr 49, B-3000 Leuven, Belgium
[4] Univ Napoli Federico II, Dipartimento Fis Ettore Pancini, Naples, Italy
[5] Univ Napoli Federico II, INFN, Sez Napoli, Naples, Italy
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2017年 / 41卷
关键词
Breast software model; Mammography; Breast software phantom; Breast imaging techniques; COMPUTED-TOMOGRAPHY; SIMULATION; PHANTOM; MAMMOGRAPHY; TOMOSYNTHESIS; PERFORMANCE;
D O I
10.1016/j.ejmp.2017.04.024
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: In X-ray imaging, test objects reproducing breast anatomy characteristics are realized to optimize issues such as image processing or reconstruction, lesion detection performance, image quality and radiation induced detriment. Recently, a physical phantom with a structured background has been introduced for both 2D mammography and breast tomosynthesis. A software version of this phantom and a few related versions are now available and a comparison between these 3D software phantoms and the physical phantom will be presented. Methods: The software breast phantom simulates a semi-cylindrical container filled with spherical beads of different diameters. Four computational breast phantoms were generated with a dedicated software application and for two of these, physical phantoms are also available and they are used for the side by side comparison. Planar projections in mammography and tomosynthesis were simulated under identical incident air kerma conditions. Tomosynthesis slices were reconstructed with an in-house developed reconstruction software. In addition to a visual comparison, parameters like fractal dimension, power law exponent beta and second order statistics (skewness, kurtosis) of planar projections and tomosynthesis reconstructed images were compared. Results: Visually, an excellent agreement between simulated and real planar and tomosynthesis images is observed. The comparison shows also an overall very good agreement between parameters evaluated from simulated and experimental images. Conclusion: The computational breast phantoms showed a close match with their physical versions. The detailed mathematical analysis of the images confirms the agreement between real and simulated 2D mammography and tomosynthesis images. The software phantom is ready for optimization purpose and extrapolation of the phantom to other breast imaging techniques. (C) 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd.
引用
收藏
页码:78 / 86
页数:9
相关论文
共 50 条
  • [21] A novel approach to digital breast tomosynthesis for simultaneous acquisition of 2D and 3D images
    Vecchio, Sara
    Albanese, Achille
    Vignoli, Paolo
    Taibi, Angelo
    EUROPEAN RADIOLOGY, 2011, 21 (06) : 1207 - 1213
  • [22] 3D/2D image registration: The impact of X-ray views and their number
    Tomazevic, Dejan
    Likar, Bostjan
    Pernus, Franjo
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2007, PT 1, PROCEEDINGS, 2007, 4791 : 450 - +
  • [23] Reproducing 2D Breast Mammography Images with 3D Printed Phantoms
    Clark, Matthew
    Ghammraoui, Bahaa
    Badal, Andreu
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [24] Artificial Intelligence in Breast X-Ray Imaging
    Vedantham, Srinivasan
    Shazeeb, Mohammed Salman
    Chiang, Alan
    Vijayaraghavan, Gopal R.
    SEMINARS IN ULTRASOUND CT AND MRI, 2023, 44 (01) : 2 - 7
  • [25] High-resolution, low-dose phase contrast X-ray tomography for 3D diagnosis of human breast cancers
    Zhao, Yunzhe
    Brun, Emmanuel
    Coan, Paola
    Huang, Zhifeng
    Sztrokay, Aniko
    Diemoz, Paul Claude
    Liebhardt, Susanne
    Mittone, Alberto
    Gasilov, Sergei
    Miao, Jianwei
    Bravin, Alberto
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2012, 109 (45) : 18290 - 18294
  • [26] Comparison of 2D and 3D Total Variation Minimization Methods in Breast Tomosynthesis Imaging
    Ertas, Metin
    Akan, Aydin
    Yildirim, Isa
    Kamasak, Mustafa
    2013 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2013,
  • [27] A software platform for phase contrast x-ray breast imaging research
    Bliznakova, K.
    Russo, R.
    Mettivier, G.
    Requardt, H.
    Popov, P.
    Bravin, A.
    Buliev, I.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2015, 61 : 62 - 74
  • [28] Novel 2D and 3D imaging of internal aerated structure of ultrasonically treated foams and cakes using X-ray tomography and X-ray microtomography
    Tan, M. C.
    Chin, N. L.
    Yusof, Y. A.
    Abdullah, J.
    JOURNAL OF FOOD ENGINEERING, 2016, 183 : 9 - 15
  • [29] Geomatics for precise 3D breast imaging
    Alto, H
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2005, 4 (01) : 29 - 38
  • [30] Dedicated 3D photoacoustic breast imaging
    Kruger, Robert A.
    Kuzmiak, Cherie M.
    Lam, Richard B.
    Reinecke, Daniel R.
    Del Rio, Stephen R.
    Steed, Doreen
    MEDICAL PHYSICS, 2013, 40 (11)