Direct electrochemistry of cytochrome c on a multi-walled carbon nanotubes modified electrode and its electrocatalytic activity for the reduction of H2O2

被引:214
作者
Zhao, GC [1 ]
Yin, ZZ [1 ]
Zhang, L [1 ]
Wei, XW [1 ]
机构
[1] Anhui Normal Univ, Sch Chem & Mat Sci, Anhui Key Lab Funct Mol Solids, Wuhu 241000, Peoples R China
基金
中国国家自然科学基金;
关键词
cytochrome c; multi-walled carbon nanotubes; direct electrochemistry; biosensor;
D O I
10.1016/j.elecom.2005.01.006
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Direct electrochemistry of cytochrome c (Cyt c), which was adsorbed on the surface of multi-walled carbon nanotubes (MWNTs), was investigated. The results from electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) suggested that Cyt c could be tightly adsorbed on the surface of MWNTs and MWNTs show an obvious promotion for the direct electro-transfer between Cyt c and electrode. A couple of well-defined and quasi-reversible CV peaks of Cyt c can be observed in a phosphate buffer solution (pH 7.0). Cyt c adsorbed on MWNTs exhibits a remarkable electrocatalytic activity for the reduction of hydrogen peroxide (11201). The calculated apparent Michaelis-Menten constant (K-m(app)) was 857 muM, indicating a high catalytic activity of Cyt c adsorbed on MWNTs modified electrode to the reduction of H2O2. Based on these, a third generation reagentless biosensor can be constructed for the determination of H2O2. (C) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:256 / 260
页数:5
相关论文
共 40 条
[21]  
Lei CH, 1999, ELECTROANAL, V11, P274, DOI 10.1002/(SICI)1521-4109(199904)11:4<274::AID-ELAN274>3.0.CO
[22]  
2-G
[23]   Hydrogen peroxide sensor based on coimmobilized methylene green and horseradish peroxidase in the same montmorillonite-modified bovine serum albumin-glutaraldehyde matrix on a glassy carbon electrode surface [J].
Lei, CH ;
Deng, JQ .
ANALYTICAL CHEMISTRY, 1996, 68 (19) :3344-3349
[24]   Silica sol-gel immobilized amperometric biosensor for hydrogen peroxide [J].
Li, J ;
Tan, SN ;
Ge, HL .
ANALYTICA CHIMICA ACTA, 1996, 335 (1-2) :137-145
[25]  
Lisdat F, 2001, ELECTROANAL, V13, P1225, DOI 10.1002/1521-4109(200110)13:15<1225::AID-ELAN1225>3.0.CO
[26]  
2-5
[27]  
LOTZBEYER T, 1997, BIOELECTROCH BIOENER, V42, P97
[28]  
MURRAY RW, 1984, ELECTROANAL CHEM, V13, P191
[29]   CHARACTERIZATION OF REGENERATED SILK FIBROIN MEMBRANE FOR IMMOBILIZING PEROXIDASE AND CONSTRUCTION OF AN AMPEROMETRIC HYDROGEN-PEROXIDE SENSOR EMPLOYING PHENAZINE METHOSULFATE AS ELECTRON SHUTTLE [J].
QIAN, JH ;
LIU, YC ;
LIU, HY ;
YU, TY ;
DENG, JQ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 397 (1-2) :157-162
[30]   Electrochemical behavior of c-type cytochromes at clay-modified carbon electrodes:: a model for the interaction between proteins and soils [J].
Sallez, Y ;
Bianco, P ;
Lojou, E .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2000, 493 (1-2) :37-49