Comparison of the standards for air kerma of the KRISS and the BIPM for 60Co gamma radiation

被引:4
|
作者
Kessler, C. [1 ]
Yi, Chul-Young [2 ]
Chung, Jae-Pil [2 ]
Roger, P. [1 ]
Allisy-Roberts, P. J. [1 ]
机构
[1] Bur Int Poids & Mesures, F-92312 Sevres, France
[2] Korea Res Inst Stand & Sci, Taejon 305340, South Korea
关键词
CHAMBER;
D O I
10.1088/0026-1394/47/1A/06021
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A direct comparison of the standards for air kerma of the Korea Research Institute of Standards and Science (KRISS), Korea, and of the Bureau International des Poids et Mesures (BIPM) was carried out in the Co-60 radiation beam of the BIPM in 2010. The result, expressed as a ratio of the KRISS and the BIPM standards for air kerma, is 0.9995 with a combined standard uncertainty of 1.6 x 10(-3). The degrees of equivalence between the KRISS and the other participants in the key comparison, designated as BIPM. RI(I)-K1, have been calculated and the results are presented in the form of a matrix. A graphical presentation is also given.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the MKEH, Hungary and the BIPM in 60Co gamma radiation
    Kessler, C.
    Burns, D.
    Machula, G.
    METROLOGIA, 2018, 55
  • [22] Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the NMIJ, Japan, and the BIPM in 60Co gamma radiation
    Bureau International des Poids et Mesures, Sèvres
    F-92312 Cedex, France
    不详
    305-8568, Japan
    Metrologia, 1 A
  • [23] Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the BFKH, Hungary and the BIPM in 60Co gamma radiation
    Kessler C.
    Burns D.
    Finta V.
    Metrologia, 2023, 60 (1 A)
  • [24] Re-evaluation of the BIPM international standard for air kerma in 60Co gamma radiation
    Burns, David T.
    Allisy, Penelope J.
    Kessler, Cecilia
    METROLOGIA, 2007, 44 (06) : L53 - L56
  • [25] Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the NPL, United Kingdom and the BIPM in 60Co gamma radiation
    Kessler, C.
    Burns, D.
    Kelly, M.
    Maughan, D. J.
    Bass, G. A.
    Homer, M. J.
    METROLOGIA, 2019, 56 (1A)
  • [26] f Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the NIM, China and the BIPM in 60Co gamma radiation
    Kessler, C.
    Burns, D.
    Wang, K.
    Fan, Y.
    Jin, S.
    Yang, X.
    METROLOGIA, 2016, 53
  • [28] Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the IST-LPSR, Portugal and the BIPM in 60Co gamma radiation
    Kessler, C.
    Burns, D.
    Cardoso, J.
    METROLOGIA, 2018, 55
  • [29] Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the SCK.CEN, Belgium and the BIPM in 60Co gamma radiation
    Kessler, C.
    Burns, D.
    Mihailescu, L. C.
    Chiriotti, S.
    METROLOGIA, 2017, 54
  • [30] Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the LNE-LNHB, France and the BIPM in 60Co gamma radiation
    Kessler, C.
    Burns, D. T.
    Delaunay, F.
    Donois, M.
    METROLOGIA, 2013, 50