Biomechanical Evaluation of Subcrestal Placement of Dental Implants: In Vitro and Numerical Analyses

被引:14
作者
Chu, Chun-Ming [1 ]
Hsu, Jui-Ting [1 ]
Fuh, Lih-Jyh [1 ]
Huang, Heng-Li [1 ]
机构
[1] China Med Univ & Hosp, Sch Dent, Taichung 404, Taiwan
关键词
Biomechanics; dental implants; dental stress analysis; finite element analysis; implants; experimental; in vitro; FINITE-ELEMENT-ANALYSIS; CRESTAL BONE; STRESS-DISTRIBUTION; OSSEOINTEGRATED IMPLANTS; HISTOMETRIC EVALUATION; LOADED IMPLANTS; 2-PART IMPLANTS; SOFT-TISSUES; DOGS; MICROGAP;
D O I
10.1902/jop.2010.100040
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: This study investigates the effect of depth of insertion in subcrestal cortical bone (SB) and thickness of connected cortical bone (CB) for a subcrestal implant placement on bone stress and strain using statistical analyses combined with experimental strain-gauge tests and numerical finite element (FE) simulations. Methods: Three experimental, artificial jawbone models and 72 FE models were prepared for evaluation of bone strain and stress around various equicrestal and subcrestal implants. For in vitro tests, rosette strain gauges were used with a data acquisition system to measure bone strain on the bucco-lingual side. The maximum von Mises stresses in the bone were statistically analyzed by analysis of variance for FE models. Results: The experimental bone strains reduced significantly (22% to 49%) as the thickness of CB increased. FE analyses indicated that the suggested CB thickness for efficiently minimizing bone stress was 0.5 to 2.5 mm. The results for the depth of SB were not absolute because obvious stress reductions only presented at a certain range of depth (0.6 to 1.2 mm). Conclusion: Within the limitations of this study, increasing the thickness of CB and maintaining the depth of SB within a limited range can provide the benefit of decreasing the stress and strain in surrounding bone for subcrestally placed implants. J Periodontol 2011;82:302-310.
引用
收藏
页码:302 / 310
页数:9
相关论文
共 34 条
[1]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[2]   Influence of occlusal forces on stress distribution in preloaded dental implant screws [J].
Alkan, I ;
Sertgöz, A ;
Ekici, E .
JOURNAL OF PROSTHETIC DENTISTRY, 2004, 91 (04) :319-325
[3]   THE INFLUENCE OF IMPLANT DIAMETER AND LENGTH ON STRESS DISTRIBUTION OF OSSEOINTEGRATED IMPLANTS RELATED TO CRESTAL BONE GEOMETRY: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS [J].
Baggi, Luigi ;
Cappelloni, Ilaria ;
Di Girolamo, Michele ;
Maceri, Franco ;
Vairo, Giuseppe .
JOURNAL OF PROSTHETIC DENTISTRY, 2008, 100 (06) :422-431
[4]   Influence of interimplant distances and placement depth on peri-implant bone remodeling of adjacent and immediately loaded Morse cone connection implants: a histomorphometric study in dogs [J].
Barros, Raquel R. M. ;
Novaes, Arthur B., Jr. ;
Muglia, Valdir A. ;
Iezzi, Giovanna ;
Piattelli, Adriano .
CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (04) :371-378
[5]   Dimension of the periimplant mucosa - Biological width revisited [J].
Berglundh, T ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1996, 23 (10) :971-973
[6]  
BRANEMARK P I, 1969, Scandinavian Journal of Plastic and Reconstructive Surgery, V3, P81
[7]   The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysis [J].
Eraslan, Oguz ;
Inan, Oezguer .
CLINICAL ORAL INVESTIGATIONS, 2010, 14 (04) :411-416
[8]  
ERICSSON I, 1995, J CLIN PERIODONTOL, V22, P255
[9]  
Eser A, 2009, INT J ORAL MAX IMPL, V24, P439
[10]   Biologic width changes around loaded implants inserted in different levels in relation to crestal bone: histometric evaluation in canine mandible [J].
Farias Pontes, Ana Emilia ;
Ribeiro, Fernando Salimon ;
Iezzi, Giovanna ;
Piattelli, Adriano ;
Cirelli, Joni Augusto ;
Marcantonio, Elcio, Jr. .
CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (05) :483-490