A coupled hybrid numerical study of tunnel longitudinal ventilation under fire conditions

被引:10
作者
Alvarez-Coedo, Diego [1 ]
Ayala, Pablo [1 ]
Cantizano, Alexis [1 ]
Wegrzynski, Wojciech [2 ]
机构
[1] Comillas Pontifical Univ, Inst Res Technol, ICAI, C Sta Cruz Marcenado 26, Madrid 28015, Spain
[2] ITB Inst Tech Budowlanej, Ul Filtrowa 1, PL-00611 Warsaw, Poland
关键词
CFD; Coupled hybrid modelling; Tunnel ventilation; Tunnel fires; FDS; Full-scale tests;
D O I
10.1016/j.csite.2022.102202
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents the validation of a coupled hybrid (1D/3D-CFD) modelling methodology, using FDS version 6.7.5, for the first time, with full-scale fire tests. Real fire conditions of the Runehamar tests with maximum heat release rates of 6 MW, 66 MW, and 119 MW are compared by assessing temperature profiles, centreline velocity, backlayering lengths, and maximum temperatures at different locations both upstream and downstream from the fire source. An expression to evaluate the length of the 3D domain where the fire is located is successfully assessed. Also, a pressure boundary condition at one of the portals is suggested to predict more precisely the inner flow conditions. The temperature profiles are accurately predicted with time-averaged differences lower than 20% beyond 40 m downstream from the fire source in the three tests. Furthermore, with the coupled hybrid approach, the backlayering length is estimated accurately with the fire of 66 MW and underestimated in the 6 MW and 119 MW fires, i.e. a maximum difference lower than 4% of the total tunnel length. The validated proposed methodology allows accurate predictions of temperature for tunnel fires and reduces the computational cost between 27% and 75% with respect to a full-CFD numerical model.
引用
收藏
页数:10
相关论文
共 37 条
[11]   Fire protection in traffic tunnels: General aspects and results of the EUREKA project [J].
Haack, A .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 1998, 13 (04) :377-381
[12]   Experimental Investigation on the Influences of Different Horizontal Fire Locations on Smoke Temperature Stratification under Tunnel Ceiling [J].
Haddad, R. K. ;
Zulkifli, R. ;
Maluk, C. ;
Harun, Z. .
JOURNAL OF APPLIED FLUID MECHANICS, 2020, 13 (04) :1289-1298
[13]  
Ingason H., 2011, Runehamar tunnel fire tests
[14]   Runehamar tunnel fire tests [J].
Ingason, Haukur ;
Li, Ying Zhen ;
Lonnermark, Anders .
FIRE SAFETY JOURNAL, 2015, 71 :134-149
[15]   Study of smoke back-layering length with different longitudinal fire locations in inclined tunnels under natural ventilation [J].
Kong, Jie ;
Xu, Zhisheng ;
You, Wenjiao ;
Wang, Beilei ;
Liang, Yin ;
Chen, Tao .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2021, 107
[16]   Numerical investigation on fire accident and evacuation in a urban tunnel for different traffic conditions [J].
Krol, Aleksander ;
Krol, Malgorzata .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2021, 109
[17]  
Li Y.Z., 2012, 6 INT C TUNNEL SAFET, P203
[18]   Verification of Similarity of Scaling Laws in Tunnel Fires with Natural Ventilation [J].
Lin, Peng ;
Xiong, Yuan-Yuan ;
Zuo, Cong ;
Shi, Jia-Kang .
FIRE TECHNOLOGY, 2021, 57 (04) :1611-1635
[19]   Gas temperatures in heavy goods vehicle fires in tunnels [J].
Lönnermark, A ;
Ingason, H .
FIRE SAFETY JOURNAL, 2005, 40 (06) :506-527
[20]   Effect of vehicular blocking scene on smoke spread in the longitudinal ventilated tunnel fire [J].
Luo, Junli ;
Xu, Zhisheng ;
Li, Fulin ;
Zhao, Jiaming .
CASE STUDIES IN THERMAL ENGINEERING, 2019, 14