gas electron multiplier;
radiation detector;
readout electronics;
D O I:
10.3938/jkps.51.1649
中图分类号:
O4 [物理学];
学科分类号:
0702 ;
摘要:
The gas electron multiplier (GEM) chamber fabricated in this experiment had a double GEM structure, and Ar and CO2 gases were used as the counting and the quencher gases, respectively, with a mixing ratio of Ar : CO2 = 80 : 20. A homemade readout board was used to read the electric signals from the GEM detector. The analog-to-digital converter (ADC) was synchronized with the trigger signal, and the converted digital values were fed to a personal computer (PC) by the data acquisition (DAQ) program. The whole detector system was tested with an Fe-55 radiation source (5.9 keV), and we calculated the mass attenuation coefficients for a Cu and an Ar/CO2 gas mixture under 5.9 keV X-ray irradiation. From the results, we found that the Cu film (cathode) played an important role in the signal generation.