Optimal retrofit of heat exchanger networks: A stepwise approach

被引:15
作者
Ayotte-Sauve, Etienne [1 ]
Ashrafi, Omid [1 ]
Bedard, Serge [1 ]
Rohani, Navid [1 ]
机构
[1] Nat Ressources Canada, CanmetENERGY, 1615 Lionel Boulet,POB 4800, Varennes, PQ J3X 1S6, Canada
关键词
Heat exchanger networks; Optimization; MINLP; Retrofit; Heat path; OPTIMIZATION APPROACH; TRANSFER INTENSIFICATION; TOPOLOGY MODIFICATIONS; TRANSFER ENHANCEMENT; FOULING MITIGATION; FLEXIBLE DESIGNS; PINCH ANALYSIS; TUBE INSERTS; RECOVERY; INTEGRATION;
D O I
10.1016/j.compchemeng.2017.06.008
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper introduces a new stepwise approach for the optimal retrofit of heat exchanger networks. At each iteration, the proposed method involves superstructures which embed retrofit alternatives as well as numerical optimization to minimize the project's total annualized cost. In order to reduce calculation times, new algorithms are proposed to thin out superstructures. These are based on thermodynamic criteria, namely on the concept of heat path, and on new graph theoretical results. To carry out the numerical optimization tasks, novel mixed integer nonlinear models are developed. These models support any combination of constant, polynomial and (continuous) piecewise linear enthalpy functions of temperature. Numerical examples are presented for the retrofit of the preheat train of an atmospheric crude unit and for the retrofit of a fluid catalytic cracking plant. The new method is shown to reduce calculation times and total annualized costs reported in the literature. Crown Copyright (C) 2017 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:243 / 268
页数:26
相关论文
共 59 条
[1]   Retrofit of heat exchanger networks with heat transfer enhancement based on an area ratio approach [J].
Akpomiemie, Mary O. ;
Smith, Robin .
APPLIED ENERGY, 2016, 165 :22-35
[2]   Retrofit of heat exchanger networks without topology modifications and additional heat transfer area [J].
Akpomiemie, Mary O. ;
Smith, Robin .
APPLIED ENERGY, 2015, 159 :381-390
[3]  
Al-Riyami B. A., 2001, APPL THERM ENG
[4]  
[Anonymous], 2018, Graph theory
[5]  
Asante D. K., 1996, THESIS
[6]  
Bagajewicz M., 2013, IND ENG CHEM
[7]   Retrofitting heat exchanger networks using a modified network pinch approach [J].
Bakhtiari, Bahador ;
Bedard, Serge .
APPLIED THERMAL ENGINEERING, 2013, 51 (1-2) :973-979
[8]   Robust model predictive control for heat exchanger network [J].
Bakosova, Monika ;
Oravec, Juraj .
APPLIED THERMAL ENGINEERING, 2014, 73 (01) :924-930
[9]   Comparison between pinch analysis and bridge analysis to retrofit the heat exchanger network of a kraft pulp mill [J].
Bonhivers, J. C. ;
Svensson, E. ;
Berntsson, T. ;
Stuart, P. R. .
APPLIED THERMAL ENGINEERING, 2014, 70 (01) :369-379
[10]  
Bonhivers J. C., 2014, APPL THERM