X-ray image denoising with fast non-local means (FNLM) approach using acceleration function in CdTe semiconductor photon counting detector (PCD): Monte Carlo simulation study

被引:4
作者
Lee, Youngjin [1 ]
机构
[1] Gachon Univ, Dept Radiol Sci, 191 Hambakmoero, Incheon, South Korea
来源
OPTIK | 2018年 / 172卷
基金
新加坡国家研究基金会;
关键词
X-ray denoising; Non-local means algorithm using acceleration function; CdTe photon counting detector; Quantitative evaluation of image performance; Monte Carlo simulation; PARALLEL-HOLE COLLIMATOR; COMPUTED-TOMOGRAPHY; SYSTEM; CAMERA; NOISE; FEASIBILITY; PERFORMANCE; SPECT;
D O I
10.1016/j.ijleo.2018.07.051
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The noise reduction algorithms have been widely used in the field of medical X-ray imaging system using semiconductor photon counting detector (PCD). Among these algorithms, fast non-local means (FNLM) method is based on use of the encoded information and considering the local region in the image. The aim of this study was to design FNLM noise reduction algorithm using acceleration function with Euclidean distance, which is feasible to cope with practical problems, and to confirm its application feasibility in CdTe PCD. We simulated X-ray imaging system with PCD using Monte Carlo simulation tool (Geant4 Application for Tomographic Emission (GATE)) version 6 and applied conventional and proposed noise reduction algorithms in acquired water phantom image. We conclude that the results of the image performances associated with noise characteristics demonstrated the superiority of the proposed FNLM noise reduction algorithm in CdTe PCD imaging system.
引用
收藏
页码:456 / 461
页数:6
相关论文
共 22 条
  • [1] Evaluation of image performance of CZT detector for digital mammography: Monte Carlo simulation
    Alsager, A. A.
    Spyrou, N. M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01) : 462 - 465
  • [2] Spectral CT imaging of vulnerable plaque with two independent biomarkers
    Baturin, Pavlo
    Alivov, Yahya
    Molloi, Sabee
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (13) : 4117 - 4138
  • [3] A non-local algorithm for image denoising
    Buades, A
    Coll, B
    Morel, JM
    [J]. 2005 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, VOL 2, PROCEEDINGS, 2005, : 60 - 65
  • [4] Energy response calibration of photon-counting detectors using x-ray fluorescence: a feasibility study
    Cho, H-M
    Ding, H.
    Ziemer, B. P.
    Molloi, S.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (23) : 7211 - 7227
  • [5] Optimization of a photon rejecter to separate electronic noise in a photon-counting detector
    Cho, Hyo-Min
    Choi, Yu-Na
    Lee, Seung-Wan
    Lee, Young-Jin
    Ryu, Hyun-Ju
    Kim, Hee-Joung
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (11) : 1840 - 1845
  • [6] Comparison of Image Uniformity with Photon Counting and Conventional Scintillation Single-Photon Emission Computed Tomography System: A Monte Carlo Simulation Study
    Kim, Ho Chul
    Kim, Hee-Joung
    Kim, Kyuseok
    Lee, Min-Hee
    Lee, Youngjin
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2017, 49 (04) : 776 - 780
  • [7] Segmentation and quantification of materials with energy discriminating computed tomography: A phantom study
    Le, Huy Q.
    Molloi, Sabee
    [J]. MEDICAL PHYSICS, 2011, 38 (01) : 228 - 237
  • [8] A Monte Carlo simulation study of the effect of energy windows in computed tomography images based on an energy-resolved photon counting detector
    Lee, Seung-Wan
    Choi, Yu-Na
    Cho, Hyo-Min
    Lee, Young-Jin
    Ryu, Hyun-Ju
    Kim, Hee-Joung
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (15) : 4931 - 4949
  • [9] A simulation study of high-resolution x-ray computed tomography imaging using irregular sampling with a photon-counting detector
    Lee, Seungwan
    Choi, Yu-Na
    Kim, Hee-Joung
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 726 : 175 - 180
  • [10] Comparison of ultra-high-resolution parallel-hole collimator materials based on the CdTe pixelated semiconductor SPECT system
    Lee, Young-Jin
    Ryu, Hyun-Ju
    Lee, Seung-Wan
    Park, Su-Jin
    Kim, Hee-Joung
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 713 : 33 - 39