Novel Differential Protection Approach of UHV AC Transmission Lines Based on Tellegen's Quasi-Power Theorem

被引:9
作者
Liu, Shiming [1 ]
Wang, Bo [1 ]
Zhao, Yongsen [1 ]
Zhang, L. L. [2 ]
Jiang, L. [3 ]
机构
[1] Shandong Univ, Minist Educ, Key Lab Power Syst Intelligent Dispatch & Control, Jinan 250061, Peoples R China
[2] South China Univ Technol, Sch Elect Power Engn, Guangzhou 510640, Peoples R China
[3] Univ Liverpool, Dept Elect Engn & Elect, Liverpool L69 3GJ, Merseyside, England
关键词
Circuit faults; Power transmission lines; Synchronization; Impedance; Transmission line measurements; Equivalent circuits; Relays; Tellegen's quasi-power theorem; differential protection; ultra-high voltage; protection relay; IMPEDANCE; SCHEME; RELAY;
D O I
10.1109/TPWRD.2021.3082855
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
When current differential protection is applied to an AC transmission line, synchronous sampling at the two ends is required. The use of GPS synchronization increases the difficulty and cost of project implementation while the use of 'ping-pong' synchronization requires that the communication channel has equal transmission and reception delay. To overcome the impact of these issues, power differential protection has been proposed. However, power differential protection cannot fully identify the fault zone for solid single-line-to-ground fault. This paper proposes a novel differential protection approach based on the Tellegen's quasi-power theorem. The approach retains the advantages of current differential protection. Meanwhile, it is not affected by load condition and distributed capacitance. This paper also proposes a time synchronization method based on the Tellegen's quasi-power theorem to calculate and correct the time synchronization error. Therefore, the proposed pilot protection has a high synchronization accuracy and has no requirement on the communication delay. In this paper, different simulation models are established by using MATLAB/Simulink and PSCAD and extensive simulation studies verify the effectiveness of the proposed protection approach and time synchronization method.
引用
收藏
页码:1264 / 1274
页数:11
相关论文
共 33 条
  • [1] Anderson P.M., 1998, Power System Protection
  • [2] [Anonymous], 2018, SIPROTEC 4 LINE DIFF
  • [3] [Anonymous], 2006, MANUAL CSC 213 OPTIC
  • [4] [Anonymous], 2018, L90 LINE CURRENT DIF
  • [5] [Anonymous], 2018, LINE CURRENT DIFFERE
  • [6] [Anonymous], 2018, L30 LINE CURRENT DIF
  • [7] Transmission lines differential protection based on the energy conservation law
    Aziz, Mohamed Mamdouh Abdel
    Zobaa, Ahmed Faheem
    Ibrahim, Doaa Khalil
    Awad, Mohammed Mohammed
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (11) : 1865 - 1872
  • [8] Bi TS, 2005, IEEE POWER ENG SOC, P770
  • [9] Impedance-Differential Protection: A New Approach to Transmission-Line Pilot Protection
    Bolandi, Tohid Ghanizadeh
    Seyedi, Heresh
    Hashemi, Sayyed Mohammad
    Nezhad, Peyman Soleiman
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (06) : 2510 - 2518
  • [10] Adaptive Current Differential Protection Schemes for Transmission-Line Protection
    Dambhare, Sanjay
    Soman, S. A.
    Chandorkar, M. C.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (04) : 1832 - 1841