Effect of 9.3 μm CO2 and 2.94 μm Er:YAG Laser vs. Bur Preparations on Marginal Adaptation in Enamel and Dentin of Mixed Class V Cavities Restored With Different Restorative Systems

被引:0
|
作者
Otero, Clara Isabel [1 ]
Di Bella, Enrico [2 ]
Krejci, Ivo [1 ]
Bortolotto, Tissiana [1 ]
机构
[1] Univ Geneva, Univ Clin Dent Med, Div Cariol & Endodontol, Fac Med,CUMD, Geneva, Switzerland
[2] Univ Genoa, Dept Econ & Quantitat Methods, Genoa, Italy
来源
FRONTIERS IN DENTAL MEDICINE | 2021年 / 2卷
关键词
dental hard tissue preparation; marginal adaptation; adhesion; Er:YAG laser; CO2; laser; laser cavity preparation; universal adhesive system; ETCH-AND-RINSE; BOND STRENGTH; UNIVERSAL ADHESIVES; PHASE-SEPARATION; ER; AGGRESSIVENESS; EVAPORATION; STRESS; CEMENT; DEPTH;
D O I
10.3389/fdmed.2021.668056
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study aimed to compare marginal adaptation in enamel and dentin before and after aging of laser vs. bur-prepared mixed class V cavities restored by different restorative systems. Seventy two caries-free human molars were distributed to nine experimental groups; cavities were prepared using two different lasers: a handpiece -integrated 2.94 mu m Er:YAG laser at 4.5W, 300 mJ, and 0.75W, 50 mJ with 15Hz (LiteTouch, Light Instruments, Israel) and a novel CO2 laser at 12.95W, 19.3 mJ, and 4.1W, 6.11 mJ with 671Hz (Solea 9.3 mu m, Convergent Dental, USA). Cavities prepared with conventional diamond burs (Intensiv, Switzerland) in a red contra angle at high speed under maximal water cooling served as control. Cavities were prepared under simulation of dentinal fluid and restored using three different self-etching universal adhesives in combination with three nanohybrid composites, applied in two layers: Scotchbond Universal with Filtek Supreme XTE (3M, USA), G-Premio BOND with Essentia Universal (GC, Japan), and OptiBond Universal with Harmonize Universal (Kerr, USA). After restorations' polishing and simultaneous thermal (5-50.C, 2min each) and mechanical loading (max. 49N; 200,000 cycles), replicas of restoration margins were examined under SEM at x200 magnification. Percentages of continuous margins (CMs) were quantified before and after the fatigue test and statistically compared (two-way ANOVA with Fisher's least significant difference [LSD] post hoc test). Significant differences were found in almost all groups between the results before and after the fatigue test, as well as between the different preparation tools and restorative materials (p < 0.05). Traditional bur preparations are confirmed as gold standard in enamel and dentin, as all three tested restorative systems provide results of marginal adaptation of more than 80% CM after loading. Er:YAG laser preparations can be equally effective in combination with SBU/Filtek Supreme XTE. CO2 laser ablation could not provide convincing results with the tested self-etching restorative systems. Marginal adaptation has been highly dependent on the substrate and showed impaired adhesion, especially in enamel.Scotchbond Universal/Filtek Supreme XTE showed the highest andmost stable values of CM. The other two restorative systems were highly dependent on the preparation device of the substrate.
引用
收藏
页数:12
相关论文
共 8 条
  • [1] Influence of 9.3 μm CO2 and Er:YAG laser preparations on marginal adaptation of adhesive mixed Class V composite restorations with one component universal adhesive
    Anton y Otero, Clara Isabel
    Bortolotto, Tissiana
    Di Bella, Enrico
    Krejci, Ivo
    AMERICAN JOURNAL OF DENTISTRY, 2021, 34 (01) : 31 - 38
  • [2] Enamel and dentin irradiation with 9.6 μm CO2 and 2.94 μm Er:YAG lasers:: bond strength evaluation
    Marraccini, TM
    Bachmann, L
    Wigdor, HA
    Walsh, JT
    Turbino, ML
    Stabholtz, A
    Zezell, DM
    LASER PHYSICS LETTERS, 2006, 3 (02) : 96 - 101
  • [3] Investigation of the Er: YAG laser and diamond bur cavity preparation on the marginal microleakage of Class V cavities restored with different flowable composites
    Tuna, Elif Bahar
    Ozel, Emre
    Kasimoglu, Yelda
    Firatli, Erhan
    MICROSCOPY RESEARCH AND TECHNIQUE, 2017, 80 (05) : 530 - 536
  • [4] Marginal adaptation of two-step self-etch versus universal adhesives for Class V restorations: Effect of Er:YAG laser vs. bur prepared cavities
    Noerpuspita, Putri
    Krejci, Ivo
    Bortolotto, Tissiana
    AMERICAN JOURNAL OF DENTISTRY, 2024, 37 (01) : 29 - 34
  • [5] Bond strength of etch-and-rinse and self-etch adhesive systems to enamel and dentin irradiated with a novel CO2 9.3 μm short-pulsed laser for dental restorative procedures
    Rechmann, Peter
    Bartolome, N.
    Kinsel, R.
    Vaderhobli, R.
    Rechmann, B. M. T.
    LASERS IN MEDICAL SCIENCE, 2017, 32 (09) : 1981 - 1993
  • [6] Effect of the erbium:yttrium-aluminum-garnet laser or diamond bur cavity preparation on the marginal microleakage of class V cavities restored with different adhesives and composite systems
    Batu Can Yaman
    Begum Efes Guray
    Can Dorter
    Yavuz Gomeç
    Oktay Yazıcıoglu
    Dina Erdilek
    Lasers in Medical Science, 2012, 27 : 785 - 794
  • [7] Effect of the erbium:yttrium-aluminum-garnet laser or diamond bur cavity preparation on the marginal microleakage of class V cavities restored with different adhesives and composite systems
    Yaman, Batu Can
    Guray, Begum Efes
    Dorter, Can
    Gomec, Yavuz
    Yazicioglu, Oktay
    Erdilek, Dina
    LASERS IN MEDICAL SCIENCE, 2012, 27 (04) : 785 - 794
  • [8] Bond strength of etch-and-rinse and self-etch adhesive systems to enamel and dentin irradiated with a novel CO2 9.3 μm short-pulsed laser for dental restorative procedures
    Peter Rechmann
    N. Bartolome
    R. Kinsel
    R. Vaderhobli
    B. M. T. Rechmann
    Lasers in Medical Science, 2017, 32 : 1981 - 1993