Arterial oxygen saturation and heart rate after birth in newborns with and without maternal bonding

被引:5
作者
Bancalari, Aldo [1 ]
Araneda, Heriberto [2 ]
Echeverria, Patricia [3 ]
Alvear, Marina [3 ]
Romero, Luzmira [3 ]
机构
[1] Univ Concepcion, Dept Pediat, 4030000 Edmundo Larenas 220, Concepcion, Chile
[2] Univ Concepcion, Dept Obstet & Gynecol, Concepcion, Chile
[3] Univ Concepcion, Guillermo Grant Benavente Hosp, Dept Childcare Neonatol Serv, Concepcion, Chile
关键词
heart rate; maternal bonding; neonate; oxygen saturation; pulse oxymeter; PULSE OXIMETRY; DELIVERY; INFANT; TERM; ACCURACY;
D O I
10.1111/ped.12991
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
BackgroundThe aim of this study was to determine and compare changes in arterial oxygen saturation (SpO(2)) and heart rate (HR) in healthy term infants with and without maternal bonding. MethodThis was a prospective observational study in healthy term infants. SpO(2) and HR were recorded from 1 to 10 min after birth. After this, SpO(2) and HR were registered at 15, 30 and 60 min and then at 12 and 24 h after birth. SpO(2) and HR were measured with a pulse oximeter. ResultsA total of 216 healthy term infants were divided into three different groups: 136 (63%) born by vaginal delivery, 56 (26%) born by cesarean section with bonding, and 24 (11%) born by cesarean section without bonding. No difference in SpO(2) was found in babies born by cesarean section with or without maternal bonding. In neonates delivered vaginally, SpO(2) was significantly higher during the first 10 min after birth than in neonates born by cesarean section with bonding (P < 0.05). Compared with infants born by cesarean section without bonding, this tendency was not significant. In general, HR was similar across groups, although, for infants born by cesarean section, neonates who received bonding had lower HR from 6 to 8 min (P < 0.05). ConclusionsIn healthy term newborns, maternal bonding in infants born by cesarean section did not have effects on SpO(2). Some differences were observed in HR between infants born by cesarean section with and without bonding.
引用
收藏
页码:993 / 997
页数:5
相关论文
共 28 条
  • [1] INFANT-MOTHER ATTACHMENT
    AINSWORTH, MDS
    [J]. AMERICAN PSYCHOLOGIST, 1979, 34 (10) : 932 - 937
  • [2] Percentiles of oxygen saturations in healthy term newborns in the first minutes of life
    Altuncu, Emel
    Ozek, Eren
    Bilgen, Huelya
    Topuzoglu, Ahmet
    Kavuncuoglu, Sultan
    [J]. EUROPEAN JOURNAL OF PEDIATRICS, 2008, 167 (06) : 687 - 688
  • [3] [Anonymous], 2006, Current Paediatrics, DOI DOI 10.1016/J.CUPE.2006.08.003
  • [4] Bancalari A, 2013, E PAS, V4516, P265
  • [5] BRADY JP, 1962, AM J OBSTET GYNECOL, V84, P1
  • [6] Pulse oximetry for monitoring infants in the delivery room: a review
    Dawson, J. A.
    Davis, P. G.
    O'Donnell, C. P. F.
    Kamlin, C. O. F.
    Morley, C. J.
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2007, 92 (01): : F4 - F7
  • [7] Defining the Reference Range for Oxygen Saturation for Infants After Birth
    Dawson, Jennifer A.
    Kamlin, C. Omar F.
    Vento, Maximo
    Wong, Connie
    Cole, Tim J.
    Donath, Susan M.
    Davis, Peter G.
    Morley, Colin J.
    [J]. PEDIATRICS, 2010, 125 (06) : E1340 - E1347
  • [8] EVALUATION OF OXYGEN-SATURATION MONITORING BY PULSE OXIMETRY IN NEONATES IN THE DELIVERY SYSTEM
    DIMICH, I
    SINGH, PP
    ADELL, A
    HENDLER, M
    SONNENKLAR, N
    JHAVERI, M
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1991, 38 (08): : 985 - 988
  • [9] Mother infant relationship and bonding myths and facts
    Giustardi, Arturo
    Stablum, Monika
    De Martino, Arianna
    [J]. JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2011, 24 : 59 - 60
  • [10] Arterial oxygen saturation in healthy newborns delivered at term in Cerro de Pasco (4340 m) and Lima (150 m)
    Gonzales, GF
    Salirrosas, A
    [J]. REPRODUCTIVE BIOLOGY AND ENDOCRINOLOGY, 2005, 3 (1)