Development and validation of a new automatic algorithm for quantification of left ventricular volumes and function in gated myocardial perfusion SPECT using cardiac magnetic resonance as reference standard

被引:15
作者
Soneson, Helen [1 ,2 ]
Hedeer, Fredrik [1 ]
Arevalo, Carmen [2 ]
Carlsson, Marcus [1 ]
Engblom, Henrik [1 ]
Ubachs, Joey F. A. [1 ]
Arheden, Hakan [1 ]
Heiberg, Einar [1 ]
机构
[1] Lund Univ, Dept Clin Physiol, Skane Univ Hosp, SE-22185 Lund, Sweden
[2] Lund Univ, Ctr Math Sci, SE-22185 Lund, Sweden
基金
瑞典研究理事会;
关键词
Myocardial perfusion imaging: SPECT; gated SPECT; left ventricular; function; magnetic resonance imaging; EMISSION COMPUTED-TOMOGRAPHY; EJECTION FRACTION; TC-99M-MIBI SPECT; GRADIENT-ECHO; HEART; ECHOCARDIOGRAPHY; INFARCTION; 4D-MSPECT; IMAGES; MODEL;
D O I
10.1007/s12350-011-9427-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. By gating image acquisition in myocardial perfusion SPECT (MPS) to ECG, left ventricular (LV) volumes and function can be determined. Several previous studies have shown that existing MPS software packages underestimate LV volumes compared to cardiac magnetic resonance (CMR). The aim of this study was therefore to develop a new LV segmentation algorithm for gated MPS using CMR as reference standard. Methods and Results. A total of 126 patients with suspected coronary artery disease, who underwent both gated MPS and CMR were retrospectively included. The proposed LV segmentation algorithm (Segment) was trained in 26 patients, and tested in 100 patients in comparison to four commercially available MPS software packages (QGS, MyoMetrix, ECTb, and Exini) using CMR as reference standard. Mean bias +/- SD between MPS and CMR was for EDV -5% +/- 12%, -43% +/- 8%, -40% +/- 8%, -42% +/- 9%, -32% +/- 7%, for ESV 0% +/- 17%, -41% +/- 16%, -34% +/- 15%, -54% +/- 13%, -41% +/- 10%, for EF -2% +/- 13%, -1% +/- 14%, -7% +/- 15%, 17% +/- 16%, 10% +/- 17% for Segment, QGS, MyoMetrix, ECTb, and Exini, respectively, and for LVM 3% +/- 18%, 33% +/- 25%, 37% +/- 24% for Segment, QGS, and ECTb, respectively. Correlation between MPS by Segment and CMR were for EDV R(2) = 0.89, for ESV R(2) = 0.92, for EF R(2) = 0.69, and for LVM R(2) = 0.72, with no difference compared to the correlation between the other MPS software packages and CMR (EDV R(2) = 0.86-0.92, ESV R(2) = 0.91-0.93, EF R(2) = 0.64-0.65, and LVM R(2) = 0.68-0.70). Conclusion. The Segment software quantifies LV volumes and EF by MPS with similar correlation and a low bias compared to other MPS software packages, using CMR as reference standard. Hence, the Segment software shows potential to provide clinically relevant volumes and functional values from MPS. (J Nucl Cardiol 2011;18:874-85.)
引用
收藏
页码:874 / 885
页数:12
相关论文
共 43 条
  • [31] The impacts of severe perfusion defects, akinetic/dyskinetic segments, and viable myocardium on the accuracy of volumes and LVEF measured by gated 99mTc-MIBI SPECT and gated 18F-FDG PET in patients with left ventricular aneurysm: cardiac magnetic resonance imaging as the reference
    Hongxing Wei
    Congna Tian
    Thomas H. Schindler
    Mei Qiu
    Minjie Lu
    Rui Shen
    Yueqin Tian
    Shi-hua Zhao
    Xiaoli Zhang
    [J]. Journal of Nuclear Cardiology, 2014, 21 : 1230 - 1244
  • [32] Reproducibility of Left Ventricular Function Derived From Cardiac Magnetic Resonance and Gated 13NAmmonia Positron Emission Tomography Myocardial Perfusion Imaging: A Head-to-Head Comparison Using Hybrid Positron Emission Tomography/Magnetic Resonance
    Sager, Dominik F.
    Manz, Nico
    Manser, Sarah
    Laubscher, Lily
    Stark, Anselm W.
    Schutze, Jonathan
    Heiniger, Pascal S.
    Markendorf, Susanne
    Kaufmann, Philipp A.
    Grani, Christoph
    Buechel, Ronny R.
    [J]. ACADEMIC RADIOLOGY, 2024, 31 (04) : 1248 - 1255
  • [33] Assessment of Left Ventricular Volumes with Echocardiography and Cardiac Magnetic Resonance Imaging: Real-Life Evaluation of Standard versus New Semiautomatic Methods
    Aurich, Matthias
    Andre, Florian
    Keller, Marius
    Greiner, Sebastian
    Hess, Alexander
    Buss, Sebastian J.
    Katus, Hugo A.
    Mereles, Derliz
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (10) : 1017 - 1024
  • [34] Assessment of Left Ventricular Systolic and Diastolic Function Using ECG-Gated Technetium-99m Tetrofosmin Myocardial Perfusion SPECT Comparison With Ultrasound Echocardiography
    Mizunobu, Mayumi
    Sakai, Jun
    Sasao, Hisataka
    Murai, Hiroshi
    Fujiwara, Hidetoshi
    [J]. INTERNATIONAL HEART JOURNAL, 2013, 54 (04) : 212 - 215
  • [35] Improved Left Ventricular Mass Quantification with Partial Voxel Interpolation - in vivo and Necropsy Validation of a Novel Algorithm for Automated Analysis of Cardiac Magnetic Resonance (CMR)
    Codella, Noel C.
    Lee, Hae Yeoun
    Fieno, David S.
    Chen, Debbie W.
    Kochar, Minisha
    Finn, John P.
    Judd, Robert
    Goyal, Parag
    Schenendorf, Jesse
    Cham, Matthew D.
    Devereux, Richard B.
    Prince, Martin
    Wang, Yi
    Weinsaft, Jonathan W.
    [J]. CIRCULATION, 2011, 124 (21)
  • [36] Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT:: MRI validation and comparison of the Emory Cardiac Tool Box with QGS and 4D-MSPECT
    Schaefer, WM
    Lipke, CSA
    Standke, D
    Kühl, HP
    Nowak, B
    Kaiser, HJ
    Koch, KC
    Buell, U
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2005, 46 (08) : 1256 - 1263
  • [37] Quantification of Right Ventricular Volume and Function Using Single-Beat Three-Dimensional Echocardiography: A Validation Study with Cardiac Magnetic Resonance
    Park, Jun-Bean
    Lee, Seung-Pyo
    Lee, Ju-Hee
    Yoon, Yeonyee E.
    Park, Eun-Ah
    Kim, Hyung-Kwan
    Lee, Whal
    Kim, Yong-Jin
    Cho, Goo-Yeong
    Sohn, Dae-Won
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2016, 29 (05) : 392 - 401
  • [38] Quantification of left ventricular mechanics using vector-velocity imaging, a novel feature tracking algorithm, applied to echocardiography and cardiac magnetic resonance imaging
    Li Peng
    Meng Hong
    Liu Shi-zhen
    Vannan, Mani A.
    [J]. CHINESE MEDICAL JOURNAL, 2012, 125 (15) : 2719 - 2727
  • [39] Left-ventricular volumes and ejection fraction from cardiac ECG-gated 15O-water positron emission tomography compared to cardiac magnetic resonance imaging using simultaneous hybrid PET/MR
    Nordstrom, Jonny
    Kvernby, Sofia
    Kero, Tanja
    Sorensen, Jens
    Harms, Hendrik J.
    Lubberink, Mark
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2023, 30 (04) : 1352 - 1362
  • [40] Left-ventricular volumes and ejection fraction from cardiac ECG-gated 15O-water positron emission tomography compared to cardiac magnetic resonance imaging using simultaneous hybrid PET/MR
    Jonny Nordström
    Sofia Kvernby
    Tanja Kero
    Jens Sörensen
    Hendrik J. Harms
    Mark Lubberink
    [J]. Journal of Nuclear Cardiology, 2023, 30 : 1352 - 1362