Development and validation of a new automatic algorithm for quantification of left ventricular volumes and function in gated myocardial perfusion SPECT using cardiac magnetic resonance as reference standard

被引:15
|
作者
Soneson, Helen [1 ,2 ]
Hedeer, Fredrik [1 ]
Arevalo, Carmen [2 ]
Carlsson, Marcus [1 ]
Engblom, Henrik [1 ]
Ubachs, Joey F. A. [1 ]
Arheden, Hakan [1 ]
Heiberg, Einar [1 ]
机构
[1] Lund Univ, Dept Clin Physiol, Skane Univ Hosp, SE-22185 Lund, Sweden
[2] Lund Univ, Ctr Math Sci, SE-22185 Lund, Sweden
基金
瑞典研究理事会;
关键词
Myocardial perfusion imaging: SPECT; gated SPECT; left ventricular; function; magnetic resonance imaging; EMISSION COMPUTED-TOMOGRAPHY; EJECTION FRACTION; TC-99M-MIBI SPECT; GRADIENT-ECHO; HEART; ECHOCARDIOGRAPHY; INFARCTION; 4D-MSPECT; IMAGES; MODEL;
D O I
10.1007/s12350-011-9427-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. By gating image acquisition in myocardial perfusion SPECT (MPS) to ECG, left ventricular (LV) volumes and function can be determined. Several previous studies have shown that existing MPS software packages underestimate LV volumes compared to cardiac magnetic resonance (CMR). The aim of this study was therefore to develop a new LV segmentation algorithm for gated MPS using CMR as reference standard. Methods and Results. A total of 126 patients with suspected coronary artery disease, who underwent both gated MPS and CMR were retrospectively included. The proposed LV segmentation algorithm (Segment) was trained in 26 patients, and tested in 100 patients in comparison to four commercially available MPS software packages (QGS, MyoMetrix, ECTb, and Exini) using CMR as reference standard. Mean bias +/- SD between MPS and CMR was for EDV -5% +/- 12%, -43% +/- 8%, -40% +/- 8%, -42% +/- 9%, -32% +/- 7%, for ESV 0% +/- 17%, -41% +/- 16%, -34% +/- 15%, -54% +/- 13%, -41% +/- 10%, for EF -2% +/- 13%, -1% +/- 14%, -7% +/- 15%, 17% +/- 16%, 10% +/- 17% for Segment, QGS, MyoMetrix, ECTb, and Exini, respectively, and for LVM 3% +/- 18%, 33% +/- 25%, 37% +/- 24% for Segment, QGS, and ECTb, respectively. Correlation between MPS by Segment and CMR were for EDV R(2) = 0.89, for ESV R(2) = 0.92, for EF R(2) = 0.69, and for LVM R(2) = 0.72, with no difference compared to the correlation between the other MPS software packages and CMR (EDV R(2) = 0.86-0.92, ESV R(2) = 0.91-0.93, EF R(2) = 0.64-0.65, and LVM R(2) = 0.68-0.70). Conclusion. The Segment software quantifies LV volumes and EF by MPS with similar correlation and a low bias compared to other MPS software packages, using CMR as reference standard. Hence, the Segment software shows potential to provide clinically relevant volumes and functional values from MPS. (J Nucl Cardiol 2011;18:874-85.)
引用
收藏
页码:874 / 885
页数:12
相关论文
共 43 条
  • [1] Development and validation of a new automatic algorithm for quantification of left ventricular volumes and function in gated myocardial perfusion SPECT using cardiac magnetic resonance as reference standard
    Helen Soneson
    Fredrik Hedeer
    Carmen Arévalo
    Marcus Carlsson
    Henrik Engblom
    Joey F. A. Ubachs
    Håkan Arheden
    Einar Heiberg
    Journal of Nuclear Cardiology, 2011, 18 : 874 - 885
  • [2] UK audit of quantification of left-ventricular function using gated myocardial perfusion imaging
    Cade, Sarah C.
    Hall, David O.
    Kenny, Bob
    Knight, Andy
    Lawson, Richard S.
    Livieratos, Lefteris
    Nijran, Kuldip S.
    White, Duncan
    NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (10) : 990 - 1004
  • [3] Evaluation of Left Ventricular Volumes and Ejection Fraction from Gated Myocardial Perfusion SPECT Processed with "Myovation Evolution": Comparison of Three Automated Software Packages using Cardiac Magnetic Resonance as Reference
    Calandri, Enrico
    Guana, Francesca
    Pultrone, Mirco
    Leuzzi, Stefano
    Chiorino, Giovanna
    Soligo, Eleonora
    Frantellizzi, Viviana
    Gallina, Sonya
    Liberatore, Mauro
    De Vincentis, Giuseppe
    CURRENT RADIOPHARMACEUTICALS, 2021, 14 (02) : 112 - 120
  • [4] Assessment of left ventricular function and volumes for patients with dilated cardiomyopathy using gated myocardial perfusion SPECT and comparison with echocardiography
    Berk, F
    Isgoren, S
    Demir, H
    Kozdag, G
    Sahin, T
    Ural, D
    Kahraman, G
    NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (08) : 701 - 710
  • [5] Quantitative polar representation of left ventricular myocardial perfusion, function and viability using SPECT and cardiac magnetic resonance: initial results
    Cain, PA
    Ugander, M
    Palmer, J
    Carlsson, M
    Heiberg, E
    Arheden, H
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2005, 25 (04) : 215 - 222
  • [6] Evaluation of left ventricular volumes and ejection fraction by automated gated myocardial SPECT versus cardiovascular magnetic resonance
    Persson, E
    Carlsson, M
    Palmer, J
    Pahlm, O
    Arheden, H
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2005, 25 (03) : 135 - 141
  • [7] Assessment of left ventricular function by gated myocardial perfusion and gated blood-pool SPECT: Can we use the same reference database?
    Asit Kf. Paul
    Shinji Hasegawa
    Jun Yoshioka
    Hitoshi Yamaguchi
    Eiichiro Tsujimura
    Tsunehiko Nishimura
    Annals of Nuclear Medicine, 2000, 14 : 75 - 80
  • [8] Gated Myocardial Perfusion SPECT: Algorithm-Specific Influence of Reorientation on Calculation of Left Ventricular Volumes and Ejection Fraction
    Knollmann, Daniela
    Winz, Oliver H.
    Meyer, Philipp T.
    Raptis, Mardjan
    Krohn, Thomas
    Koch, Karl-Christian
    Schaefer, Wolfgang M.
    JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (10) : 1636 - 1642
  • [9] Assessment of left ventricular function by gated myocardial perfusion and gated blood-pool SPECT: Can we use the same reference database?
    Paul, AK
    Hasegawa, S
    Yoshioka, J
    Yamaguchi, H
    Tsujimura, E
    Nishimura, T
    ANNALS OF NUCLEAR MEDICINE, 2000, 14 (02) : 75 - 80
  • [10] Gated myocardial perfusion SPECT underestimates left ventricular volumes and shows high variability compared to cardiac magnetic resonance imaging -- a comparison of four different commercial automated software packages
    Hedeer F.
    Palmer J.
    Arheden H.
    Ugander M.
    BMC Medical Imaging, 10 (1)