Residual astigmatism produced by toric intraocular lens rotation

被引:109
|
作者
Felipe, Adelina [1 ,2 ]
Artigas, Jose M. [1 ,2 ]
Diez-Ajenjo, Amparo [1 ,2 ]
Garcia-Domene, Carmen [2 ]
Alcocer, Pablo [2 ]
机构
[1] Univ Valencia, Fac Fis, Dept Opt, E-46100 Burjassot, Valencia, Spain
[2] Univ Valencia, Fac Fis, Fdn Oftalmol Mediterraneo, E-46100 Burjassot, Valencia, Spain
关键词
CORRECTING ASTIGMATISM; CATARACT PATIENTS; STABILITY; IMPLANTATION; EXPERIENCE; CENTRATION; EYES;
D O I
10.1016/j.jcrs.2011.04.036
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To analyze changes in the eye's refractive properties when a toric intraocular lens (IOL) rotates. SETTING: Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. DESIGN: Experimental study. METHODS: The matrix definition of astigmatism was used in this theoretical study and compared with another vector representation. Two methods were compared: (1) The cylinder, C, resulting from the addition of 2 cylinders C(1) and C(2) whose axes form an angle a, is obtained by the addition of 2 vectors of values C(1) and C(2) forming an angle 2a; (2) the power matrix, F, of a thin astigmatic dioptric system that decomposes naturally into 3 orthogonal components: the purely spherical part F(nes), the ortho-astigmatism F(or), and oblique astigmatism F(ob). RESULTS: The residual cylinder was one third of the corneal astigmatism when a toric IOL rotated +/- 10 degrees when the cylinder values for the cornea (C(1)) and IOL (C(2)) were equal. Nevertheless, in most cases C(1) is greater than C(2); therefore, the residual astigmatism did not change noticeably with small rotations. The angle of rotation, b, which annuls the astigmatism correction, could be obtained from the following: cos(pi + 2b) = -r/2, with r being the ratio between the IOL and cornea cylinders. CONCLUSIONS: The 2 methods gave equivalent results. When the IOL cylinder had a value different from that of the corneal astigmatism, a better choice would be a lower, rather than higher, cylinder value to reduce residual astigmatism. In general, toric IOL rotations less than 10 degrees changed the eye's refraction less than 0.50 diopter. Thus, small axis rotations are not an obstacle for satisfactory astigmatism correction with toric IOLs.
引用
收藏
页码:1895 / 1901
页数:7
相关论文
共 50 条
  • [31] Phacoemulsification with corneal astigmatism correction with the use of a toric intraocular lens in a case of megalocornea
    Rekas, Marek
    Pawlik, Rafal
    Klus, Adam
    Rozycki, Radoslaw
    Szaflik, Jacek Pawel
    Oldak, Monika
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (08) : 1546 - 1550
  • [32] Accuracy of Toric Intraocular Lens Calculators with Predicted and Measured Posterior Corneal Astigmatism Across Different Types of Astigmatism
    Yang, Soonwon
    Park, Jaehyun
    Whang, Woong Joo
    Byun, Yong-Soo
    Kim, Hyun Seung
    Chung, So-Hyang
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (07) : 1877 - 1889
  • [33] Clinical Outcomes of TECNIS Toric Intraocular Lens Implantation after Cataract Removal in Patients with Corneal Astigmatism
    Waltz, Kevin L.
    Featherstone, Kristen
    Tsai, Linda
    Trentacost, Debbie
    OPHTHALMOLOGY, 2015, 122 (01) : 39 - 47
  • [34] New algorithm for toric intraocular lens power calculation considering the posterior corneal astigmatism
    Canovas, Carmen
    Alarcon, Aixa
    Rosen, Robert
    Kasthurirangan, Sanjeev
    Ma, Joseph J. K.
    Koch, Douglas D.
    Piers, Patricia
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (02) : 168 - 174
  • [35] Rotation stability of a toric intraocular lens with a second capsular tension ring
    Sagiv, Oded
    Sachs, Dan
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (05) : 1098 - 1099
  • [36] Predictability of different calculators in the minimization of postoperative astigmatism after implantation of a toric intraocular lens
    Ribeiro, Filomena J.
    Ferreira, Tiago B.
    Reha, Catarina
    Esteves, Carina
    Gaspar, Sylvia
    CLINICAL OPHTHALMOLOGY, 2019, 13 : 1649 - 1656
  • [37] Astigmatism management in cataract surgery with Precizon (R) toric intraocular lens: a prospective study
    Vale, Carolina
    Menezes, Carlos
    Firmino-Machado, J.
    Rodrigues, Pedro
    Lume, Miguel
    Tenedorio, Paula
    Meneres, Pedro
    Brochado, Maria do Ceu
    CLINICAL OPHTHALMOLOGY, 2016, 10 : 151 - 159
  • [38] Accuracy of Toric Intraocular Lens Formulas With Measured Posterior Corneal Astigmatism of Different Orientations
    Stewart, Stephen
    Yeo, Tun Kuan
    Moutari, Salissou
    McNeely, Richard
    Moore, Jonathan
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 266 : 26 - 36
  • [39] Long-term changes in the refractive effect of a toric intraocular lens on astigmatism correction
    Hayashi, Ken
    Yoshida, Motoaki
    Hayashi, Shunsuke
    Hirata, Akira
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 260 (02) : 509 - 519
  • [40] The neutralization of corneal astigmatism during cataract surgery using toric intraocular lens: results
    Centurion, Virgilio
    Lacava, Augusto Cezar
    Caballero, Juan Carlos
    REVISTA BRASILEIRA DE OFTALMOLOGIA, 2009, 68 (02) : 76 - 82