Noncontact sphygmomanometer based on pulse-wave transit time between the face and hand

被引:0
作者
Nakano, Kazuya [1 ]
Ohnishi, Takashi [1 ]
Nishidate, Izumi [2 ]
Haneishi, Hideaki [1 ]
机构
[1] Chiba Univ, Ctr Frontier Med Engn, Inage Ku, 1-33 Yayoi Cho, Chiba 2638522, Japan
[2] Tokyo Univ Agr & Technol, Grad Sch Bioapplicat & Syst Engn, 2-24-16 Naka Cho, Koganei, Tokyo 1848588, Japan
来源
OPTICAL DIAGNOSTICS AND SENSING XVIII: TOWARD POINT-OF-CARE DIAGNOSTICS | 2018年 / 10501卷
关键词
Pulse transit time; sphygmomanometer; contactless sensing; hemodynamics; blood pressure; VELOCITY; SKIN;
D O I
10.1117/12.2289349
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Systolic blood pressure (SBP) is highly sensitive to various factors such as psychological stress, and hence its continuous monitoring is essential to evaluate different health conditions. However, conventional sphygmomanometers cannot continuously measure SBP given the time-consuming setup based on a pressure cuff. Moreover, continuous biological signal monitoring is more comfortable when no sensors are attached. A solution for continuous SBP estimation is based on pulse transit time (PTT), which determines the time difference between two pulse waves at different body parts. In previous studies, we successfully measured the PTT using a contactless setup composed by two digital color cameras recording the face and hand of subjects. Then, the acquired images were transformed into blood volume by combining multiple regression analysis and a Monte Carlo method. As a result, the delay among images allowed to determine the PPT from pulse waves. In this study, we simultaneously measured SBP and PTT by using a sphygmomanometer and the two cameras, respectively. We evaluated SBP increases (i.e., stressful situations) and the corresponding PPT by asking participants to either grasp a handgrip or momentarily interrupting breath. We also determined the SBP and PTT without asking for such exercises. Comparison results show that the mean PTT under stress was significantly lower than that without stress, which is consistent with an increased SBP. Finally, we related the SBP and PTT by a nonlinear formula with a coefficient of determination of 0.59, thus confirming the effectiveness of the proposed system.
引用
收藏
页数:8
相关论文
共 14 条
  • [1] [Anonymous], 1877, THESIS
  • [2] MEASUREMENTS OF YOUNGS MODULUS OF ELASTICITY OF THE CANINE AORTA WITH ULTRASOUND
    HUGHES, DJ
    BABBS, CF
    GEDDES, LA
    BOURLAND, JD
    [J]. ULTRASONIC IMAGING, 1979, 1 (04) : 356 - 367
  • [3] Korteweg DJ., 1878, Annalen der Physik, V241, P525, DOI [10.1002/andp.18782411206, DOI 10.1002/ANDP.18782411206]
  • [4] Continuous Blood Pressure Monitoring in Daily Life
    Lopez, Guillaume
    Shuzo, Masaki
    Ushida, Hiroyuki
    Hidaka, Keita
    Yanagimoto, Shintaro
    Imai, Yasushi
    Kosaka, Akio
    Delaunay, Jean-Jacques
    Yamada, Ichiro
    [J]. JOURNAL OF ADVANCED MECHANICAL DESIGN SYSTEMS AND MANUFACTURING, 2010, 4 (01): : 179 - 186
  • [5] Luster EA, 1996, AVIAT SPACE ENVIR MD, V67, P308
  • [6] Adaptive hydrostatic blood pressure calibration: Development of a wearable, autonomous pulse wave velocity blood pressure monitor
    McCombie, Devin B.
    Shaltis, Phillip A.
    Reisner, Andrew T.
    Asada, H. Harry
    [J]. 2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 370 - +
  • [7] Milnor W. R., 1982, HEMODYNAMICS
  • [8] Moens A., 1878, Die Pulskurve
  • [9] Brachial-Ankle Pulse Wave Velocity in the Measurement of Arterial Stiffness: Recent Evidence and Clinical Applications
    Munakata, Masanori
    [J]. CURRENT HYPERTENSION REVIEWS, 2014, 10 (01) : 49 - 57
  • [10] Nakano K., 2016, P SOC PHOTO-OPT INS