Experimental performance of double built-up T moment connections under cyclic loading

被引:17
作者
Herrera, Ricardo [1 ]
Salas, Constanza [1 ,2 ]
Felipe Beltran, Juan [1 ]
Nunez, Eduardo [1 ]
机构
[1] Univ Chile, Dept Civil Engn, Blanco Encalada 2002, Santiago, Chile
[2] Jacobs Chile, Apoquindo 5400, Santiago, Chile
关键词
Moment connection; Failure modes; Partially restrained connection; Cyclic tests; T-stub; BEHAVIOR; STUBS;
D O I
10.1016/j.jcsr.2017.08.022
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Prequalification of the Double Split Tee (DST) connection has been conducted using hot-rolled shapes, whose availability is still limited in several countries. In addition, the range of available T web and flange thicknesses is narrow for these shapes. Thus, the use of built-up T-stubs on the DST connection seems to be a promising alternative, considering that they offer more freedom of sizing and allow a better use of the material. The experimental research reported here aimed to validate the use of built-up tees instead of hot rolled tees in DST moment connections. Four beam-to-column full-scale double built-up T (DBT) moment connections were subjected to cyclic loading following the prescribed loading history in AISC seismic provisions. The parameters varied among the specimens were the T flange thickness, the type of weld between the T flange and the stem (fillet weld or full penetration groove weld), and the column web thickness, in order to observe the most significant limit states of the connection, namely development of plastic hinges in beams, panel zone plastification, and T flange prying. The results indicate that the connection can sustain 4% drift without strength degradation, whether it is designed for T flange prying or beam hinging. In the case of the former, only limited permanent deformation of the flange is observed, while for the latter significant plastic deformation of the beam can be achieved with little or no damage of the T. The type of weld used has no significant effect on the connection performance. (c) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:742 / 749
页数:8
相关论文
共 17 条
[1]  
AISC, 2016, 35816 ANSI AISC APP
[2]  
Alarcon C., 2017, THESIS
[3]  
American Institute of Steel Construction (AISC), 2010, ANSIAISC34110
[4]  
[Anonymous], 1999, THESIS
[5]  
[Anonymous], 2010, SPEC STRUCT STEEL BU
[6]  
Arriols Nunez Eduardo, 2016, THESIS
[7]   Performance under cyclic load of built-up T-stubs for Double T moment connections [J].
Bravo, Miguel A. ;
Herrera, Ricardo A. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 103 :117-130
[8]   Experimental assessment of the behaviour of bolted T-stub connections made up of welded plates [J].
Coelho, AMG ;
Bijlaard, FSK ;
Gresnigt, N ;
da Silva, LS .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2004, 60 (02) :269-311
[9]  
FEMA, 2000, FEMA355E STAT ART RE
[10]  
FEMA, 2000, FEMA350 REC SEISM DE