Contrast-enhanced magnetic resonance angiography of the iliac arteries: Optimization by injection simulation

被引:3
|
作者
Schmidt, MA
Britten, AJ
Tomlinson, MA
Vig, S
Powell, S
Cleminson, S
Kerr, E
Blundell, J
Heron, CW
机构
[1] Univ London St Georges Hosp, Dept Med Phys, London, England
[2] Univ London St Georges Hosp, Dept Vasc Surg, London, England
[3] Univ London St Georges Hosp, Dept Radiol, London, England
关键词
magnetic resonance angiography; CAs; optimization; impulse response function; iliac arteries;
D O I
10.1002/mrm.1199
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Protocols for contrast-enhanced magnetic resonance angiography (CE-MRA) of the iliac arteries were optimized by computer simulations based on an impulse response function (IRF) of contrast agent (CA) concentration as a function of time obtained for 20 patients. Protocols with sequential, centric, and elliptical k-space coverage, different repetition rates (5 and 10 ms), and CA doses (0.1, 0.2, and 0.3 mmol/kg b.w.) were compared in terms of signal-to-noise ratio (SNR), distortion of vessel profiles, and sensitivity to timing errors. IRF-based simulations successfully characterized CA recirculation. Slow-rate CA infusions were found to achieve relatively high enhancement. In terms of SNR, there is no advantage in increasing the repetition rate. Distortion of vessel profiles is more likely in elliptic and centric k-space coverage. Protocols based on sequential k-space coverage and relatively long CA infusions proved to be particularly suited to large-FOV iliac examinations as they are relatively insensitive to timing errors. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:365 / 373
页数:9
相关论文
共 50 条
  • [1] Contrast-enhanced magnetic resonance angiography carotid arteries
    U-King-Im, J
    Trivedi, R
    Gillard, JH
    STROKE, 2003, 34 (05) : E15 - E15
  • [2] On contrast-enhanced magnetic resonance angiography of the aortoiliac arteries.
    Wikström, J
    ACTA RADIOLOGICA, 2001, 42 : 1 - +
  • [3] Contrast-enhanced magnetic resonance angiography of cerebral arteries - A review
    Parker, DL
    Tsuruda, JS
    Goodrich, KC
    Alexander, AL
    Buswell, HR
    INVESTIGATIVE RADIOLOGY, 1998, 33 (09) : 560 - 572
  • [4] Contrast-enhanced magnetic resonance angiography in the coronary and peripheral arteries
    Saeed, M
    Wendland, MF
    Engelbrecht, M
    Sakuma, H
    Higgins, CB
    ACADEMIC RADIOLOGY, 1998, 5 : S108 - S112
  • [5] Contrast-enhanced magnetic resonance angiography of the cervical arteries - A review
    Steffens, JC
    Link, J
    Heller, M
    INVESTIGATIVE RADIOLOGY, 1998, 33 (09) : 573 - 577
  • [6] Contrast-enhanced magnetic resonance angiography of the renal arteries - Original investigation
    Hany, TF
    Leung, DA
    Pfammatter, T
    Debatin, JF
    INVESTIGATIVE RADIOLOGY, 1998, 33 (09) : 653 - 659
  • [7] Contrast-Enhanced Magnetic Resonance Angiography
    Vasile, Julie V.
    Newman, Tiffany M.
    Prince, Martin R.
    Rusch, David G.
    Greenspun, David T.
    Allen, Robert J.
    Levine, Joshua L.
    CLINICS IN PLASTIC SURGERY, 2011, 38 (02) : 263 - +
  • [8] Contrast-Enhanced Magnetic Resonance Angiography
    Chandra, Tushar
    Pukenas, Bryan
    Mohan, Suyash
    Melhem, Elias
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2012, 20 (04) : 687 - +
  • [9] Contrast-enhanced magnetic resonance angiography
    Roditi, G
    BRITISH JOURNAL OF SURGERY, 2002, 89 (07) : 817 - 820
  • [10] CONTRAST-ENHANCED MAGNETIC-RESONANCE ANGIOGRAPHY
    VOGL, TJ
    HOFFMANN, Y
    MUHLER, A
    FELIX, A
    RADIOLOGE, 1994, 34 (08): : 423 - 429