Perspectives of excimer laser-assisted keratoplasty

被引:0
作者
Seitz, B. [1 ]
Langenbucher, A. [2 ]
Naumann, G. O. H. [3 ]
机构
[1] UKS, Klin Augenheilkunde, D-66421 Homburg, Germany
[2] Univ Saarland, Lehrstuhl Expt Ophthalmol, Homburg, Germany
[3] Univ Erlangen Nurnberg, Augenklin Poliklin, D-8520 Erlangen, Germany
来源
OPHTHALMOLOGE | 2011年 / 108卷 / 09期
关键词
Excimer laser; Trepanation; Keratoplasty; Femtosecond laser; Laser keratoplasty; NONMECHANICAL CORNEAL TREPHINATION; PENETRATING KERATOPLASTY; 193; NM; POSTKERATOPLASTY ASTIGMATISM; REGULARITY; IMPACT; DECENTRATION; KERATOCONUS;
D O I
10.1007/s00347-011-2333-x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background and purpose. The purpose of this paper is to demonstrate the evolution of laser keratoplasty and to outline the potential future perspectives of this technique. Methods. For non-contact donor trephination from the epithelial side an artificial anterior chamber has been used. Since 1989 more than 3,300 penetrating keratoplasty operations (PKP) have been performed successfully with the Zeiss-Meditec MEL60A (R) excimer laser in Erlangen and Homburg/Saar. Results. Prospective clinical studies have shown that the technique of non-contact excimer laser PKP improves donor and recipient decentration, reduces vertical tilt and horizontal torsion of the graft in the recipient bed, thus resulting in significantly less all-sutures-out keratometric astigmatism, higher regularity of the topography and better visual acuity. Besides less blood-aqueous barrier breakdown during the early postoperative course after PKP, excimer laser trephination does not induce cataract formation and does not impair the graft endothelium. Likewise, the rate of immunological graft rejections is not adversely affected by the excimer laser. In addition, trephination of an instable cornea is facilitated. Conclusions. Because of undisputed clinical advantages, especially in eyes with keratoconus, excimer laser trephination with orientation teeth/notches is still favored in Homburg/Saar in daily practice. The femtosecond laser (FSL)-assisted keratoplasty technique is very exciting but a prospective randomized study is required to determine potential benefits over excimer laser PKP.
引用
收藏
页码:817 / 824
页数:8
相关论文
共 30 条
[1]   Orientation teeth in non-mechanical laser corneal trephination for penetrating keratoplasty:: 2.94 μm Er:YAG v 193 nm ArF excimer laser [J].
Behrens, A ;
Seitz, B ;
Küchle, M ;
Langenbucher, A ;
Kus, NM ;
Rummelt, C ;
Naumann, GOH .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1999, 83 (09) :1008-1012
[2]  
BEHRENS A, 2000, J CATARACT REFR SURG, V26, P1588
[3]   Nonmechanical excimer laser penetrating keratoplasty for perforated or predescemetal corneal ulcers [J].
Küchle, M ;
Seitz, B ;
Langenbucher, A ;
Naumann, GOH .
OPHTHALMOLOGY, 1999, 106 (11) :2203-2209
[4]   Blood-aqueous barrier after mechanical or nonmechanical excimer laser trephination in penetrating keratoplasty [J].
Kuchle, M ;
Nguyen, NX ;
Seitz, B ;
Langenbucher, A ;
Naumann, GOH .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 125 (02) :177-181
[5]   A NEW ELLIPTIC EXCISION FOR CORNEAL TRANSPLANTATION USING AN EXCIMER LASER [J].
LANG, GK ;
NAUMANN, GOH ;
KOCH, JW .
ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (07) :914-915
[6]  
LANG GK, 1989, OPHTHALMIC SURG LAS, V20, P342
[7]  
Langenbucher A, 1998, OPHTHALMIC SURG LAS, V29, P106
[8]   Regularity of corneal topography after penetrating keratoplasty - Nonmechanical trephination with the excimer laser 193 nm vs mechanical trephination [J].
Langenbucher, A ;
Seitz, B ;
Kus, MM ;
Vilchis, E ;
Naumann, GOH .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1996, 208 (06) :450-458
[9]   Vertical tilt after penetrating keratoplasty - Comparison between nonmechanical trephination with the excimer laser and motor trephination [J].
Langenbucher, A ;
Seitz, B ;
Kus, MM ;
Naumann, GOH .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1998, 212 (03) :129-140
[10]   Corneal endothelial cell loss after nonmechanical penetrating keratoplasty depends on diagnosis: a regression analysis [J].
Langenbucher, A ;
Seitz, B ;
Nguyen, NX ;
Naumann, GOH .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2002, 240 (05) :387-392