Molecular mass analysis of antibodies by on-line SEC-MS

被引:54
作者
Brady, Lowell J. [1 ]
Valliere-Douglass, John [1 ]
Martinez, Theresa [1 ]
Balland, Alain [1 ]
机构
[1] Amgen Inc, Dept Proc & Analyt Sci, Seattle, WA 98119 USA
关键词
D O I
10.1016/j.jasms.2007.12.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Mass analysis of recombinant protein therapeutics is an important assay for product characterization. Intact mass analysis is used to provide confirmation of proper translation of the DNA sequence and to detect the presence of post-translational modifications such as amino acid processing and glycosylation. We present here a method for the rapid mass analysis of antibodies using a polyhydroxyethyl aspartamide column operated in size-exclusion mode and coupled with ESI-MS. This method allows extremely efficient desalting of proteins under acidic conditions that are optimal for subsequent mass analysis using standard ESI conditions. Furthermore, this technique is significantly faster and more sensitive than rpHPLC methods, typically considered the standard chromatography approach for mass analysis of proteins. This method is flexible and robust, and should prove useful for applications where a combination of speed and sensitivity are required.
引用
收藏
页码:502 / 509
页数:8
相关论文
共 16 条
[1]   HYDROPHILIC-INTERACTION CHROMATOGRAPHY FOR THE SEPARATION OF PEPTIDES, NUCLEIC-ACIDS AND OTHER POLAR COMPOUNDS [J].
ALPERT, AJ .
JOURNAL OF CHROMATOGRAPHY, 1990, 499 :177-196
[2]  
BRADY LJ, IN PRESS ANAL CHEM
[3]   Formation of pyroglutamic acid from N-terminal glutamic acid in immunoglobulin gamma antibodies [J].
Chelius, D ;
Jing, K ;
Lueras, A ;
Rehder, DS ;
Dillon, TM ;
Vizel, A ;
Rajan, RS ;
Li, TS ;
Treuheit, MJ ;
Bondarenko, PV .
ANALYTICAL CHEMISTRY, 2006, 78 (07) :2370-2376
[4]  
CHU G, 2007, PHARM RES, V12, P1145
[5]   Non-enzymatic hinge region fragmentation of antibodies in solution [J].
Cordoba, AJ ;
Shyong, BJ ;
Breen, D ;
Harris, RJ .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 818 (02) :115-121
[6]   Optimization of a reversed-phase high-performance liquid chromatography/mass spectrometry method for characterizing recombinant antibody heterogeneity and stability [J].
Dillon, TM ;
Bondarenko, PV ;
Rehder, DS ;
Pipes, GD ;
Kleemann, GR ;
Ricci, MS .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1120 (1-2) :112-120
[7]   Development of an analytical reversed-phase high-performance liquid chromatography-electro spray ionization mass spectrometry method for characterization of recombinant antibodies [J].
Dillon, TM ;
Bondarenko, PV ;
Ricci, MS .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1053 (1-2) :299-305
[8]   Improving mass accuracy of high performance liquid chromatography/electrospray ionization time-of-flight mass spectrometry of intact antibodies [J].
Gadgil, Himanshu S. ;
Pipes, Gary D. ;
Dillon, Thomas M. ;
Treuheit, Michael J. ;
Bondarenko, Pavel V. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2006, 17 (06) :867-872
[9]   Analysis of the composition of immunoconjugates using size-exclusion chromatography coupled to mass spectrometry [J].
Lazar, AC ;
Wang, LT ;
Blättler, WA ;
Amphlett, G ;
Lambert, JM ;
Zhang, W .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (13) :1806-1814
[10]   Fluorescent derivatization method of proteins for characterization by capillary elect rophoresis-sodium dodecyl sulfate with laser-induced fluorescence detection [J].
Michels, David A. ;
Brady, Lowell J. ;
Guo, Amy ;
Balland, Alain .
ANALYTICAL CHEMISTRY, 2007, 79 (15) :5963-5971