Non-invasive blood glucose sensing on human body with near-infrared reflection spectroscopy

被引:2
|
作者
Huang Zhen-hao [1 ]
Hao Chang-ning [2 ]
Zhang Lin-lin [2 ]
Huang Yan-chao [2 ]
Shi Yi-qin [1 ]
Jiang Geng-ru [1 ]
Duan Jun-li [2 ]
机构
[1] Shanghai Jiao Tong Univ, Xinhua Hosp, Dept Nephrol, Shanghai 200092, Peoples R China
[2] Shanghai Jiao Tong Univ, Xinhua Hosp, Dept Gernotol, Shanghai 200092, Peoples R China
来源
INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2011: ADVANCES IN INFRARED IMAGING AND APPLICATIONS | 2011年 / 8193卷
关键词
Non-invasive sensing; blood glucose; near infrared; human body;
D O I
10.1117/12.900160
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The non-invasive blood glucose sensing method has shown its high impact on the clinic application. This can make the measurement on the clinically relevant concentrations of glucose be free from the pain of patient. The transmission spectrum study indicates that the dependence of glucose concentration on the absorbance is in linear manner for the glucose concentration in the region of 30mg/dL to 4.5x104mg/dL. By the near infrared reflection spectroscopy of fiber spectrometer, the reflection band between 1.2 mu m and 1.35 mu m can be used to correlated with the glucose concentration in the range of 30 to 300 mg/dL. This reflection band is finally used to measure the glucose concentration effect in non-invasive manner, which gives the statistical significance of P value 0.02. Our experiment result shows that it is possible to get the glucose concentration by the near infrared reflection spectrum measurement on the human forefinger. This non-invasive blood glucose sensing method may useful in clinic after more experiment for different people.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Research of transmissive near infrared spectroscopy for non-invasive blood glucose measurement
    Yang, Wenming
    Liao, Ningfang
    Li, Yasheng
    Shao, Liwei
    Huang, Dehuang
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS VII, 2017, 0024
  • [22] Near-Infrared Spectroscopy (NIRS) for Non-Invasive Diagnosis
    Baig, Saeeda
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2023, 33 (11): : 1215 - 1216
  • [23] Functional near-infrared spectroscopy in non-invasive neuromodulation
    Huo, Congcong
    Xu, Gongcheng
    Xie, Hui
    Chen, Tiandi
    Shao, Guangjian
    Wang, Jue
    Li, Wenhao
    Wang, Daifa
    Li, Zengyong
    NEURAL REGENERATION RESEARCH, 2024, 19 (07) : 1517 - 1522
  • [24] Evaluation and Validation on Sensitivity of Near-Infrared Diffuse Reflectance in Non-Invasive Human Blood Glucose Measurement
    Ge, Qing
    Han, Tongshuai
    Liu, Rong
    Zhang, Zengfu
    Sun, Di
    Liu, Jin
    Xu, Kexin
    SENSORS, 2024, 24 (18)
  • [25] Preliminary study of mechanism of non-invasive blood glucose measurement based on near-infrared diffuse reflectance spectroscopy
    Chen, WL
    Liu, R
    Luo, YH
    Han, YH
    Xu, KX
    Complex Dynamics and Fluctuations in Biomedical Photonics II, 2005, 5696 : 91 - 100
  • [26] A Non-Invasive Blood Insulin and Glucose Monitoring System based on Near-Infrared Spectroscopy with Remote Data Logging
    Nandi, Bodhayan
    Mondal, Prosenjit
    Chowdhury, Shubhajit Roy
    2018 31ST IEEE INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS 2018), 2018, : 274 - 279
  • [27] Performance of a Non-Invasive System for Monitoring Blood Glucose Levels Based on Near-Infrared Spectroscopy Technology (Glucube®)
    Gomez-Peralta, Fernando
    Romero, Luis Gabriel Luque
    Puppo-Moreno, Antonio
    Riesgo, Jesus
    SENSORS, 2024, 24 (23)
  • [28] Calibration break-through for near-infrared, non-invasive blood glucose monitoring
    Garg, SK
    Fischer, JS
    Ruchti, TL
    Blank, TB
    Lorenz, AD
    Monfre, SL
    DIABETES, 2002, 51 : A122 - A122
  • [29] Determination of the reference position in the near-infrared non-invasive blood glucose measurement in vivo
    Han, Guang
    Liu, Jin
    Liu, Rong
    Xu, Kexin
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS VII, 2017, 0024
  • [30] Enhancing calibration models for non-invasive near-infrared spectroscopical blood glucose determination
    Fischbacher, C
    Jagemann, KU
    Danzer, K
    Muller, UA
    Papenkordt, L
    Schuler, J
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (01): : 78 - 82