Negative ion RF sources for ITER NBI: status of the development and recent achievements

被引:103
作者
Fantz, U. [1 ]
Franzen, P. [1 ]
Kraus, W. [1 ]
Berger, M. [1 ]
Christ-Koch, S. [1 ]
Froeschle, M. [1 ]
Gutser, R. [1 ]
Heinemann, B. [1 ]
Martens, C. [1 ]
McNeely, P. [1 ]
Riedl, R. [1 ]
Speth, E. [1 ]
Wuenderlich, D. [1 ]
机构
[1] Max Planck Inst Plasma Phys, EURATOM Assoc, D-85748 Garching, Germany
关键词
D O I
10.1088/0741-3335/49/12B/S53
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
For heating and current drive the neutral beam injection system for ITER requires a deuterium beam with an energy of 1 MeV for up to 1 h. In order to inject the required 17 MW the ion source has to deliver 40 A of negative ion current. For an accelerated current density of 200 A m(-2) at the specified source pressure of 0.3 Pa the extraction area is 0.2 m(2) resulting in a large area source of 1.5 x 0.6 m(2). Two types of sources have been under discussion, the filamented arc source and the inductively driven RF source, the latter now having been chosen for the ITER reference design. The development of negative ion RF sources, which fulfil these specifications is being carried out at the Max-Planck-Institut fur Plasmaphysik at three test facilities in parallel. The required current densities at the ITER relevant pressure have been achieved and even exceeded in a test facility equipped with a small ion source (extraction area of 0.007 m(2)) at limited pulse length (<4 s). The extraction area can be extended up to 0.03 m(2) and the pulse length up to 3600 s at a second test facility which is dedicated to long pulse operation experiments where pulses up to 800 s have already been achieved. The ion source at the third test facility has roughly the full width and half the height of the ITER source but is not equipped with an extraction system. The aim is to demonstrate the size scaling and plasma homogeneity of RF ion sources. First results from different diagnostic techniques (optical emission spectroscopy and Langmuir probe) are very promising.
引用
收藏
页码:B563 / B580
页数:18
相关论文
共 28 条
  • [1] Photodetachment diagnostic techniques for measuring negative ion densities and temperatures in plasmas
    Bacal, M
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (11) : 3981 - 4006
  • [2] BERGER M, 2007, UNPUB PLASMA SOURCE
  • [3] BERGER M, 2006, THESIS U AUGSBURG
  • [4] INTENSE, MIXED-ENERGY HYDROGEN BEAMS FOR CTR INJECTION
    BERKNER, KH
    PYLE, RV
    STEARNS, JW
    [J]. NUCLEAR FUSION, 1975, 15 (02) : 249 - 254
  • [5] CHRISTKOCH S, 2007, UNPUB PLASMA SOURCES
  • [6] DIETRICH S, 2007, P ICPIG C EL PROB EL
  • [7] DUDIN S, 2007, UNPUB PLASMA SOURCES
  • [8] A novel diagnostic technique for H-(D-) densities in negative hydrogen ion sources
    Fantz, U.
    Wuenderlich, D.
    [J]. NEW JOURNAL OF PHYSICS, 2006, 8
  • [9] Plasma diagnostic tools for optimizing negative hydrogen ion sources
    Fantz, U.
    Falter, H. D.
    Franzen, P.
    Speth, E.
    Hemsworth, R.
    Boilson, D.
    Krylov, A.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (03)
  • [10] Spectroscopy- : a powerful diagnostic tool in source development
    Fantz, U.
    Falter, H.
    Franzen, P.
    Wuenderlich, D.
    Berger, M.
    Lorenz, A.
    Kraus, W.
    McNeely, P.
    Riedl, R.
    Speth, E.
    [J]. NUCLEAR FUSION, 2006, 46 (06) : S297 - S306