The measurement of a fibrinogen α C-chain 5.9 kDa fragment (FIC 5.9) using MALDI-TOF MS and a stable isotope-labeled peptide standard dilution

被引:6
作者
Sogawa, Kazuyuki [2 ]
Kodera, Yoshio [2 ,3 ]
Noda, Kenta
Ishizuka, Yusuke
Yamada, Mako
Umemura, Hiroshi
Maruyama, Katsuya [4 ]
Tomonaga, Takeshi [2 ,5 ]
Yokosuka, Osamu [6 ]
Nomura, Fumio [1 ,2 ]
机构
[1] Chiba Univ, Dept Mol Diag, Grad Sch Med, Chuo Ku, Chiba 2608670, Japan
[2] Chiba Univ Hosp, Clin Prote Res Ctr, Chiba, Japan
[3] Kitasato Univ, Ctr Dis Prote, Sch Sci, Kanagawa, Japan
[4] Natl Hosp Org Kurihama Alcoholism Ctr, Kanagawa, Japan
[5] Natl Inst Biomed Innovat, Lab Proteome Res, Osaka, Japan
[6] Chiba Univ Hosp, Div Gastroenterol, Chiba, Japan
关键词
Alcoholism; FIC; 5.9; MALDI-TOF MS; Serum; Stable isotope-labeled; FLIGHT MASS-SPECTROMETRY; IDENTIFICATION; TECHNOLOGY; BIOMARKERS; PROTEOMICS; HEPCIDIN; MARKERS;
D O I
10.1016/j.cca.2011.02.029
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: We previously identified a 5.9 kDa peptide fragment of fibrinogen a C-chain (FIC 5.9) as a novel biomarker candidate for heavy drinking. In an effort to improve FIC 5.9 measurement for potential use in clinical diagnostics, we combined the ClinProt System and a stable isotope-labeled peptide standard dilution as a simple and reproducible system for measuring FIC 5.9. Methods: We analyzed 104 serum samples that were obtained from patients with alcohol dependency, from patients with chronic hepatitis C, and from healthy volunteers. Serum FIC 5.9 levels were measured using the ClinProt system with and without a stable isotope-labeled synthetic FIC 5.9 as an internal standard. Results: The within-day and between-day CVs were significantly smaller with stable isotope dilution mass spectrometry (SID-MS) than with conventional MALDI-TOF MS. Of the two different MALDI-TOF MS platforms, we obtained concordant results with SID-MS. Furthermore, only SID-MS detected a small but significant difference between the serum FIC 5.9 levels in the chronic hepatitis C group and the controls. Conclusions: MALDI-TOF MS with a stable isotope-labeled peptide spike can determine serum FIC 5.9 levels more precisely than conventional MS. This will make inter-laboratory FIC 5.9 comparisons possible. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1094 / 1099
页数:6
相关论文
共 13 条
  • [1] Quantification of hepcidin using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    Bansal, Sukhvinder S.
    Halket, John M.
    Fusova, Jane
    Bomford, Adrian
    Simpson, Robert J.
    Vasavda, Nisha
    Thein, Swee Lay
    Hider, Robert C.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (11) : 1531 - 1542
  • [2] Identification and confirmation of increased fibrinopeptide A serum protein levels in gastric cancer sera by magnet bead assisted MALDI-TOF mass spectrometry
    Ebert, Matthias P. A.
    Niemeyer, Dagmar
    Deininger, Soren O.
    Wex, Thomas
    Knippig, Claudia
    Hoffmann, Juliane
    Sauer, Jorg
    Albrecht, Wolfgang
    Malfertheiner, Peter
    Rocken, Christoph
    [J]. JOURNAL OF PROTEOME RESEARCH, 2006, 5 (09) : 2152 - 2158
  • [3] Clinical proteomics: searching for better tumour markers with SELDI-TOF mass spectrometry
    Engwegen, Judith Y. M. N.
    Gast, Marie-Christine W.
    Schellens, Jan H. M.
    Beijnen, Jos H.
    [J]. TRENDS IN PHARMACOLOGICAL SCIENCES, 2006, 27 (05) : 251 - 259
  • [4] Multiple Reaction Monitoring Cubed for Protein Quantification at the Low Nanogram/Milliliter Level in Nondepleted Human Serum
    Fortin, T.
    Salvador, A.
    Charrier, J. P.
    Lenz, C.
    Bettsworth, F.
    Lacoux, X.
    Choquet-Kastylevsky, G.
    Lemoine, J.
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (22) : 9343 - 9352
  • [5] Potential biomarkers for esophageal carcinoma detected by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    Liu, Li-Hua
    Shan, Bao-En
    Tian, Zi-Qiang
    Sang, Mei-Xiang
    Ai, Jun
    Zhang, Ze-Feng
    Meng, Jun
    Zhu, Hui
    Wang, Shi-Jie
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (06) : 855 - 861
  • [6] Liu Wentao, 2010, Front Biosci (Elite Ed), V2, P961
  • [7] Identification of novel and downregulated biomarkers for alcoholism by surface enhanced laser desorption/ionization-mass spectrometry
    Nomura, F
    Tomonaga, T
    Sogawa, K
    Ohashi, T
    Nezu, M
    Sunaga, M
    Kondo, N
    Iyo, M
    Shimada, H
    Ochiai, T
    [J]. PROTEOMICS, 2004, 4 (04) : 1187 - 1194
  • [8] Mass spectrometry-based proteomics turns quantitative
    Ong, SE
    Mann, M
    [J]. NATURE CHEMICAL BIOLOGY, 2005, 1 (05) : 252 - 262
  • [9] Diagnostic values of surface-enhanced laser desorption/ionization technology for screening of habitual drinkers
    Sogawa, Kazuyuki
    Itoga, Sakae
    Tomonaga, Takeshi
    Nomura, Fumio
    [J]. ALCOHOLISM-CLINICAL AND EXPERIMENTAL RESEARCH, 2007, 31 : 22S - 26S
  • [10] A search for novel markers of alcohol abuse using magnetic beads and MALDI-TOF/TOF mass spectrometry
    Sogawa, Kazuyuki
    Satoh, Mamoru
    Kodera, Yoshio
    Tomonaga, Takeshi
    Iyo, Masaomi
    Nomura, Fumio
    [J]. PROTEOMICS CLINICAL APPLICATIONS, 2009, 3 (07) : 821 - 828