Factory-calibrated continuous glucose monitoring and capillary blood glucose monitoring in a case with insulinoma: usefulness and possible pitfall under chronic hyperinsulinemic hypoglycemia

被引:4
|
作者
Suminaga, Keiichiro [1 ]
Murakami, Takaaki [1 ]
Yabe, Daisuke [1 ,2 ]
Sone, Masakatsu [1 ]
Sugawa, Taku [3 ]
Masui, Toshihiko [4 ]
Uza, Norimitsu [5 ]
Yoshizawa, Akihiko [6 ]
Ogura, Masahito [1 ]
Yasoda, Akihiro [1 ,3 ]
Inagaki, Nobuya [1 ]
机构
[1] Kyoto Univ, Dept Diabet Endocrinol & Nutr, Grad Sch Med, Kyoto, Japan
[2] Gifu Univ, Dept Diabet & Endocrinol, Grad Sch Med, Gifu, Japan
[3] Natl Hosp Org Kyoto Med Ctr, Dept Endocrinol & Metab, Kyoto, Japan
[4] Kyoto Univ, Dept Hepatobiliary Pancreat Surg & Transplantat, Grad Sch Med, Kyoto, Japan
[5] Kyoto Univ, Dept Gastroenterol & Hepatol, Grad Sch Med, Kyoto, Japan
[6] Kyoto Univ, Dept Diagnost Pathol, Grad Sch Med, Kyoto, Japan
关键词
Insulinoma; Flash glucose monitoring; Continuous glucose monitoring; Hypoglycemia; Hypoglycemia unawareness; DIAGNOSIS;
D O I
10.1507/endocrj.EJ19-0339
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The accuracy of factory-calibrated continuous glucose monitoring (fCGM) within hypoglycemic ranges, especially under the status of chronic hyperinsulinemic hypoglycemia like insulinomas, remains an issue. Even so, fCGM is known to be useful for detecting hypoglycemia unawareness in insulinoma cases. A 25-year-old woman presenting with sudden unconsciousness was diagnosed with insulinoma; ICGM facilitated diagnosis by continuous monitoring for hypoglycemia. Before surgery, she was treated with continuous and frequent bolus infusions of 50% glucose via central venous catheter. To evaluate the accuracy of fCGM values in this case, a comparison between fCGM and capillary blood glucose (CBG) values was also performed. According to the simultaneously measured values, those of ICGM were largely in accordance with those of CBG. Moreover, compared with the previously reported case not having glucose infusions via central venous catheter, both the mean absolute relative differences (MARDs) and the absolute differences (Delta glucose) between MGM and CBG values were larger in the present case, although no significant differences of MARDs and Delta glucose between the two cases were observed in several different conditions including fasting, post-meal, hypoglycemia, and others. Therefore, we should note possible increased differences between fCGM and CBG values in cases using frequent intravenous glucose infusions as well as case-dependent differing levels of consistency between them.
引用
收藏
页码:361 / 366
页数:6
相关论文
共 50 条
  • [21] Factory-Calibrated Continuous Glucose Monitoring Systems in Type 1 Diabetes: Accuracy during In-Clinic Exercise and Home Use
    Lundemose, Sissel Banner
    Laugesen, Christian
    Ranjan, Ajenthen Gayathri
    Norgaard, Kirsten
    SENSORS, 2023, 23 (22)
  • [22] Regarding "The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System," by Bailey et al.
    Weiss, Ray F.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 (03) : 239 - 240
  • [23] Accuracy of a 14-Day Factory-Calibrated Continuous Glucose Monitoring System With Advanced Algorithm in Pediatric and Adult Population With Diabetes
    Alva, Shridhara
    Bailey, Timothy
    Brazg, Ronald
    Budiman, Erwin S.
    Castorino, Kristin
    Christiansen, Mark P.
    Forlenza, Gregory
    Kipnes, Mark
    Liljenquist, David R.
    Liu, Hanqing
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (01): : 70 - 77
  • [24] Comment on "The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System" by Bailey et al.
    Freckmann, Guido
    Pleus, Stefan
    Schlueter, Sandra
    Heinemann, Lutz
    DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 (05) : 334 - 335
  • [25] Experience with Real-Time Continuous Glucose Monitoring in Newborns with Congenital Hyperinsulinemic Hypoglycemia
    Anik, Ayse
    Turkmen, Munevver Kaynak
    Akcan, Abdullah Baris
    Unuvar, Tolga
    Ozturk, Sercan
    Anik, Ahmet
    ZEITSCHRIFT FUR GEBURTSHILFE UND NEONATOLOGIE, 2021, 225 (02): : 155 - 160
  • [26] INITIAL CLINICAL PERFORMANCE OF A FACTORY-CALIBRATED, REAL-TIME CONTINUOUS GLUCOSE MONITORING SYSTEM USING DIRECT ELECTRON TRANSFER TECHNOLOGY
    Yan, X.
    Wu, X.
    Yang, L.
    Li, X.
    Gao, F.
    Fei, J.
    Zhou, Z.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 : A8 - A8
  • [27] Detection of Hypoglycemia with Continuous Interstitial and Traditional Blood Glucose Monitoring Using the FreeStyle Navigator Continuous Glucose Monitoring System
    McGarraugh, Geoffrey
    Bergenstal, Richard
    DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 (03) : 145 - 150
  • [28] Response to the Comment on "The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System" by Bailey et al.
    Bailey, Timothy S.
    Alva, Shridhara
    Bode, Bruce W.
    Christiansen, Mark P.
    Klaff, Leslie J.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 (05) : 336 - 337
  • [29] Accuracy of a Factory-Calibrated, Real-Time Continuous Glucose Monitoring System During 10 Days of Use in Youth and Adults with Diabetes
    Wadwa, R. Paul
    Laffel, Lori M.
    Shah, Viral N.
    Garg, Satish K.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 (06) : 395 - 402
  • [30] Analytical Performance of the Factory-Calibrated Flash Glucose Monitoring System FreeStyle Libre2™ in Healthy Women
    Jin, Zhuoxiu
    Thackray, Alice E.
    King, James A.
    Deighton, Kevin
    Davies, Melanie J.
    Stensel, David J.
    SENSORS, 2023, 23 (17)