Optical Coherence Tomography Accurately Measures Corneal Power Change from Laser Refractive Surgery

被引:30
作者
McNabb, Ryan P. [1 ,2 ]
Farsiu, Sina [1 ,2 ]
Stinnett, Sandra S. [2 ,3 ]
Izatt, Joseph A. [1 ,2 ]
Kuo, Anthony N. [2 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[2] Duke Univ, Dept Ophthalmol, Durham, NC USA
[3] Duke Univ, Dept Biostat & Informat, Durham, NC USA
基金
美国国家卫生研究院;
关键词
INTRAOCULAR-LENS POWER; IN-SITU KERATOMILEUSIS; MYOPIC PHOTOREFRACTIVE KERATECTOMY; REQUIRING CATARACT-SURGERY; ANTERIOR SEGMENT; VOLUMETRIC SDOCT; BIOMETRY; EYES; FORMULA; VIVO;
D O I
10.1016/j.ophtha.2014.10.003
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the ability of motion-corrected optical coherence tomography (OCT) to measure the corneal refractive power change due to LASIK. Design: Evaluation of a diagnostic test or technology in a cohort. Subjects: A total of 70 eyes from 37 subjects undergoing LASIK were measured preoperatively. A total of 39 eyes from 22 subjects were measured postoperatively and completed the study. Methods: Consecutive patients undergoing LASIK at the Duke Eye Center who consented to participate were imaged with Placido-ring topography, Scheimpflug photography, and OCT on the day of their surgery. Patients were then reimaged with the same imaging systems at the postoperative month 3 visit. Change in preoperative to postoperative corneal refractive power as measured by each of the imaging modalities was compared with the preoperative to postoperative change in manifest refraction (MRx) using the t test with generalized estimating equations. Main Outcome Measures: Corneal refractive power change due to LASIK as measured by Placido-ring topography, Scheimpflug photography, and OCT compared with the MRx change vertexed to the corneal plane. The change in MRx should correspond to the change in the corneal refractive power from LASIK and was considered the reference measurement. Results: In 22 individuals (39 eyes) returning after LASIK, we found no significant difference between the clinically measured pre- to post-LASIK change in MRx and both Scheimpflug photography (P = 0.714) and OCT (P = 0.216). In contrast, keratometry values from Placido-ring topography were found to be significantly different from the measured refractive change (P < 0.001). In addition, of the 3 imaging modalities, OCT recorded the smallest mean absolute difference from the reference measurement with the least amount of variability. Conclusions: Motion-corrected OCT more accurately measures the change in corneal refractive power due to laser refractive surgery than other currently available clinical devices. By offering accurate corneal refractive power measurements in normal and surgically modified subjects, OCT offers a compelling alternative to current clinical devices for determining corneal refractive power. (C) 2015 by the American Academy of Ophthalmology.
引用
收藏
页码:677 / 686
页数:10
相关论文
共 44 条
  • [31] Intraocular lens power calculation after myopic refractive surgery - Theoretical comparison of different methods
    Savini, Giacomo
    Barboni, Piero
    Zanini, Maurizio
    [J]. OPHTHALMOLOGY, 2006, 113 (08) : 1271 - 1282
  • [32] Schwiegerling J., 2004, FIELD GUIDE VISUAL O
  • [33] Underestimation of intraocular lens power for cataract surgery after myopic photorefractive keratectomy
    Seitz, B
    Langenbucher, A
    Nguyen, NX
    Kus, MM
    Küchle, M
    [J]. OPHTHALMOLOGY, 1999, 106 (04) : 693 - 702
  • [34] No-history method of intraocular lens power calculation for cataract surgery after myopic laser in situ keratomileusis
    Shammas, H. John
    Shammas, Maya C.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (01) : 31 - 36
  • [35] Anterior segment biometry with the Pentacam: Comprehensive assessment of repeatability of automated measurements
    Shankar, Hema
    Taranath, Deepa
    Santhirathelagan, Chandramalar T.
    Pesudovs, Konrad
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (01) : 103 - 113
  • [36] Comparison of Corneal Powers Obtained from 4 Different Devices
    Shirayama, Mariko
    Wang, Li
    Weikert, Mitchell P.
    Koch, Douglas D.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (04) : 528 - 535
  • [37] Enhanced depth imaging spectral-domain optical coherence tomography
    Spaide, Richard F.
    Koizumi, Hideki
    Pozonni, Maria C.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 146 (04) : 496 - 500
  • [38] IN-VIVO RETINAL IMAGING BY OPTICAL COHERENCE TOMOGRAPHY
    SWANSON, EA
    IZATT, JA
    HEE, MR
    HUANG, D
    LIN, CP
    SCHUMAN, JS
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. OPTICS LETTERS, 1993, 18 (21) : 1864 - 1866
  • [39] Measuring total corneal power before and after laser in situ keratomileusis with high-speed optical coherence tomography
    Tang, Maolong
    Li, Yan
    Avila, Mariana
    Huang, David
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11) : 1843 - 1850
  • [40] Corneal power measurement with Fourier-domain optical coherence tomography
    Tang, Maolong
    Chen, Alex
    Li, Yan
    Huang, David
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (12) : 2115 - 2122