Narrow-beam X-ray tests of CCD edge response

被引:2
|
作者
Kuhlmann, Stephen [1 ]
Spinka, Harold [1 ]
Bernstein, Joseph P. [1 ]
Beyer, Kevin A. [1 ]
Gades, Lisa M. [1 ]
Kasprzyk, Thomas E. [1 ]
Miceli, Antonino [1 ]
Spence, Richard A. [1 ]
Talaga, Richard [1 ]
机构
[1] Argonne Natl Lab, Lemont, IL 60439 USA
关键词
CCD; X-ray; Dark energy Survey;
D O I
10.1007/s10686-010-9204-3
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The physical boundaries of a fully-depleted CCD can lead to distorted field lines and non-uniform response. We study this response with a beam of X-rays constrained to a width of less than one pixel (15 mu m), and a system to map the CCD response as a function of transverse position.
引用
收藏
页码:135 / 144
页数:10
相关论文
共 50 条
  • [1] Narrow-beam X-ray tests of CCD edge response
    Stephen Kuhlmann
    Harold Spinka
    Joseph P. Bernstein
    Kevin A. Beyer
    Lisa M. Gades
    Thomas E. Kasprzyk
    Antonino Miceli
    Richard A. Spence
    Richard Talaga
    Experimental Astronomy, 2011, 29 : 135 - 144
  • [2] An empirical model of diagnostic x-ray attenuation under narrow-beam geometry
    Mathieu, Kelsey B.
    Kappadath, S. Cheenu
    White, R. Allen
    Atkinson, E. Neely
    Cody, Dianna D.
    MEDICAL PHYSICS, 2011, 38 (08) : 4546 - 4555
  • [3] NARROW BEAM X-RAY INTERFEROMETER
    INDENBOM, VL
    SLOBODETSKII, IS
    TRUNI, KG
    ZHURNAL EKSPERIMENTALNOI I TEORETICHESKOI FIZIKI, 1974, 66 (03): : 1110 - 1120
  • [4] NARROW-BEAM ATTENUATION CURVE AS A FUNCTIONAL DESCRIPTION OF A LOW-ENERGY X-RAY-BEAM
    DELGADO, V
    ORTIZ, P
    X-RAY SPECTROMETRY, 1991, 20 (06) : 343 - 344
  • [5] A model of the X-ray response of the ACIS CCD
    Prigozhin, G
    Rasmussen, A
    Bautz, M
    Ricker, G
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS, 1998, 3444 : 267 - 275
  • [6] X-RAY DIFFRACTOMETER WITH A NARROW BEAM ACCORDING TO BRAGG
    TRUNI, KG
    VARDANYAN, DM
    KRISTALLOGRAFIYA, 1978, 23 (03): : 477 - 482
  • [7] The hard X-ray response of the XIS-CCD for Astro-E: qualification of the X-ray CCD detector
    Nishiuchi, M
    Koyama, K
    Awaki, H
    Tsuru, T
    Sakano, M
    Hamaguchi, K
    Murakami, H
    Tsunemi, H
    Hayashida, K
    Kitamoto, S
    Miyata, E
    Dotani, T
    Ozaki, M
    Bautz, M
    Doty, J
    Kissel, S
    Foster, R
    Ricker, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2): : 79 - 84
  • [8] Hard X-ray response of the XIS-CCD for ASTRO-E: qualification of the X-ray CCD detector
    Nishiuchi, M.
    Koyama, K.
    Awaki, H.
    Tsuru, T.
    Sakano, M.
    Hamaguchi, K.
    Murakami, H.
    Tsunemi, H.
    Hayashida, K.
    Kitamoto, S.
    Miyata, E.
    Dotani, T.
    Ozaki, M.
    Bautz, M.
    Doty, J.
    Kissel, S.
    Foster, R.
    Ricker, G.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999, 436 (1-2): : 79 - 84
  • [10] A structure measurement of the CCD pixel by using the X-ray beam
    Tsunemi, H
    Yoshita, K
    Kitamoto, S
    Miyata, E
    EUX, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VIII, 1997, 3114 : 230 - 240