Influence of Power Quality on FortisAlberta's PLC Based Automatic Meter Reading System

被引:0
作者
Long, Xun [1 ]
Parent, Wayne [1 ]
Staff, Eric [1 ]
机构
[1] FortisAlberta, Power Qual, Calgary, AB, Canada
来源
2015 IEEE ELECTRICAL POWER AND ENERGY CONFERENCE (EPEC) | 2015年
关键词
Power line carrier; power quality; automated meter reading; smart grid;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Automatic Meter Reading (AMR) is a basic requirement of smart metering, which enables one-way or two-way communication with meters by utilizing modern communication technologies, such as Radio Frequency (RF), Cellular and Power Line Carrier (PLC). A PLC based AMR system uses power lines as the carrier for transmitting metering data. It has been widely used in North America due to its capability of accessing the whole distribution network of a utility, making it an economical solution for rural based or sparsely populated areas. However, by sharing power lines with various types of devices and loads, the PLC signals are inevitably exposed to interferences from customer operations and system equipment. This paper will introduce the implementation of a PLC based AMR system at FortisAlberta, and present the findings from investigations about the influence of power quality on the AMR system, followed by a discussion of a troubleshooting process to deal with interferences and resonances.
引用
收藏
页码:164 / 168
页数:5
相关论文
共 50 条
[41]   A web-based power quality monitoring system [J].
Leou, RC ;
Chang, YC ;
Teng, JH .
2001 POWER ENGINEERING SOCIETY SUMMER MEETING, VOLS 1-3, CONFERENCE PROCEEDINGS, 2001, :1504-1508
[42]   An Internet-based power quality monitoring system [J].
Monteiro, ME ;
Moura, ES ;
Drago, AB ;
Bonino, LO ;
Pereira, JG ;
Amaral, PFS ;
Simonetti, DSL ;
Rosa, PF ;
Bazelatto, GD .
2003 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1 AND 2, 2003, :333-336
[43]   Design of Power Quality Monitoring System Based on DSP [J].
He, Hongjiang ;
Wang, Qingqing ;
He, Mingxing .
SECOND INTERNATIONAL SYMPOSIUM ON COMPUTATIONAL INTELLIGENCE AND DESIGN, VOL 2, PROCEEDINGS, 2009, :345-348
[44]   Power Quality Monitoring System Based on Wireless Transmission [J].
Che, Yanbo ;
Ren, Jingding .
INFORMATION TECHNOLOGY FOR MANUFACTURING SYSTEMS II, PTS 1-3, 2011, 58-60 :423-428
[45]   Power Quality analyzer based on modular CompactRIO system [J].
Zidek, Jan ;
Bilik, Petr .
EPE: PROCEEDINGS OF THE 9TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2008, 2008, :125-129
[46]   Design of Power Quality Monitoring System Based on LabVIEW [J].
Tang, Qiu ;
Teng, Zhaosheng ;
Guo, Siyu ;
Wang, Yaonan .
2009 INTERNATIONAL CONFERENCE ON MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION, VOL I, 2009, :292-295
[47]   Rule based system for power quality disturbance classification incorporating S-transform features [J].
Salem, Mohammad E. ;
Mohamed, Azah ;
Samad, Salina Abdul .
EXPERT SYSTEMS WITH APPLICATIONS, 2010, 37 (04) :3229-3235
[48]   Discussion on the System of Electricity Price Charge System Based on Power Quality [J].
Li Yonggang ;
Li Ting ;
Ma Guanhua ;
Guo Ren ;
Du Yuncheng ;
Wu Tong .
2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
[49]   Research on improving power quality of wind power system based on the flywheel energy storage system [J].
Li, Junhui ;
Bi, Jianglin ;
Yan, Gangui ;
Ge, Yanfeng ;
Jin, Peng .
2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,
[50]   Research on improving power quality of wind power system based on the flywheel energy storage system [J].
Li, Junhui ;
Bi, Jianglin ;
Yan, Gangui ;
Ge, Yanfeng ;
Jin, Peng .
2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,