Introduction: Obstruction to flow in the left pulmonary artery (LPA) is a well-known complication after transcatheter device closure of patent ductus arteriosus (PDA). This complication has been studied for different devices using lung perfusion radionuclide scintigraphy (LPRS), but not for Amplatzer devices. This study was performed to evaluate the effect of such devices on lung perfusion using LPRS. Methods: This is a retrospective study that looked at all patients who had PDA closure using different Amplatzer devices at our center between July 1999 and January 2007. All patients underwent LPRS within 24 hr of the procedure. We compared LPRS with other hemodynamic data obtained by cardiac catheterization and echocardiography. Results are presented as mean +/- SD or median and ranges. Results: A total of 70 patients had PDA closure using an Amplatzer device; median age was 1.8 years (4 months to 75 years) and median weight was 12 kg (5-112 Kg). Nine patients had associated cardiac anomalies. Sixty eight patients had available LPRS. The mean percent of left lung perfusion (LLP) was 42.7% (+/-6.7%). Excluding patients with pre-existing LPA stenosis, 17% had abnormally decreased LLP. On hemodynamic measurements, 62 patients had available direct pressure measurements following PDA closure. None had significant increase. No correlation was found with echocardiographic data. Conclusion: PDA closure with Amplatzer family of devices is associated with a relatively significant risk of decreased perfusion to the left lung, mostly mild abnormalities. Comparison with catheterization and echocardiographic measurements showed lack of correlation with LPRS findings. (C) 2011 Wiley-Liss, Inc.
引用
收藏
页码:664 / 670
页数:7
相关论文
共 50 条
  • [31] Closure of large patent ductus arteriosus using the Amplatzer Septal Occluder
    Garcia-Montes, Jose A.
    Camacho-Castro, Anahi
    Sandoval-Jones, Juan P.
    Buendia-Hernandez, Alfonso
    Calderon-Colmenero, Juan
    Patino-Bahena, Emilia
    Zabal, Carlos
    CARDIOLOGY IN THE YOUNG, 2015, 25 (03) : 491 - 495
  • [32] Transcatheter Closure of Adult Patent Ductus Arteriosus with Severe Pulmonary Hypertension
    Ji, Qiang
    Feng, Jing
    Mei, Yunqing
    Wang, Xisheng
    Cai, Jiangzhi
    Sun, Yifeng
    Zhou, Yongxin
    Li, Dawen
    Wang, Yongwu
    HYPERTENSION RESEARCH, 2008, 31 (11) : 1997 - 2002
  • [33] Transcatheter Closure of Adult Patent Ductus Arteriosus with Severe Pulmonary Hypertension
    Qiang Ji
    Jing Feng
    Yunqing Mei
    Xisheng Wang
    Jiangzhi Cai
    Yifeng Sun
    Yongxin Zhou
    Dawen Li
    Yongwu Wang
    Hypertension Research, 2008, 31 : 1997 - 2002
  • [34] A Challenging Interventional Procedure: Transcatheter Closure of Tubular Patent Ductus Arteriosus in Patients with Pulmonary Hypertension
    Yucel, Ilker Kemal
    Epcacan, Serdar
    Bulut, Mustafa Orhan
    Demir, Ibrahim Halil
    Surucu, Murat
    Yilmaz, Emine Hekim
    Kardas, Murat
    Kanlioglu, Pinar
    Celebi, Ahmet
    PEDIATRIC CARDIOLOGY, 2024, 45 (08) : 1636 - 1651
  • [35] Transcatheter Device Closure of Patent Ductus Arteriosus
    Sultan, Mehboob
    Ullah, Maad
    Sadiq, Nadeem
    Akhtar, Khurram
    Akbar, Hajira
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2014, 24 (10): : 710 - 713
  • [36] Radionuclide evaluation of lung perfusion after transcatheter closure of patent ductus arteriosus: analysis of frequently used two different types of coils
    Polat, Tugcin Bora
    Celebi, Ahmet
    Hacimahmutoglu, Sevim
    Akdeniz, Celal
    Erdem, Abdullah
    Firat, Fatih
    ANADOLU KARDIYOLOJI DERGISI-THE ANATOLIAN JOURNAL OF CARDIOLOGY, 2011, 11 (03): : 218 - 223
  • [37] Comparison of transcatheter patent ductus arteriosus closure between children and adults
    Yasuhara, Jun
    Kuno, Toshiki
    Kumamoto, Takashi
    Kojima, Takuro
    Shimizu, Hiroyuki
    Yoshiba, Shigeki
    Kobayashi, Toshiki
    Sumitomo, Naokata
    HEART AND VESSELS, 2020, 35 (11) : 1605 - 1613
  • [38] Transcatheter closure of a 16 mm hypertensive patent ductus arteriosus with the Amplatzer muscular VSD occluder
    Demkow, M
    Ruzyllo, W
    Siudalska, H
    Kepka, C
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 52 (03) : 359 - 362
  • [39] Right patent ductus arteriosus with an ipsilateral aortic arch:: Percutaneous closure with amplatzer devices
    Santiago, Justo
    Acuna, Manuel
    Arispe, Elizabeth
    Camargo, Ronaldo
    Neves, Juliana
    Arnoni, Daniel
    Fontes, Valmir F.
    Pedra, Carlos A. C.
    REVISTA ESPANOLA DE CARDIOLOGIA, 2007, 60 (03): : 319 - 322
  • [40] Safety and Efficacy of Transcatheter Closure of Patent Ductus Arteriosus With Severe Mitral Regurgitation in Adults
    Wang, Zhongkai
    Chen, Tao
    Chen, Liang
    Qin, Yongwen
    Zhao, Xianxian
    JOURNAL OF INVASIVE CARDIOLOGY, 2016, 28 (01) : 30 - 33