Pulmonary Perfusion Scans Following Transcatheter Patent Ductus Arteriosus Closure Using the Amplatzer Devices

被引:17
作者
Kharouf, Rami [1 ]
Heitschmidt, Mary [1 ]
Hijazi, Ziyad M. [1 ]
机构
[1] Rush Univ, Med Ctr, Rush Ctr Congenital & Struct Heart Dis, Chicago, IL 60612 USA
关键词
patent ductus arteriosus; lung perfusion; transcatheter closure; Amplatzer device; LUNG PERFUSION; COIL OCCLUSION; BLOOD-FLOW; CATHETER CLOSURE; GIANTURCO COILS; OCCLUDER DEVICE; OBSTRUCTION; EXPERIENCE; IMMEDIATE; INFANTS;
D O I
10.1002/ccd.22917
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Obstruction to flow in the left pulmonary artery (LPA) is a well-known complication after transcatheter device closure of patent ductus arteriosus (PDA). This complication has been studied for different devices using lung perfusion radionuclide scintigraphy (LPRS), but not for Amplatzer devices. This study was performed to evaluate the effect of such devices on lung perfusion using LPRS. Methods: This is a retrospective study that looked at all patients who had PDA closure using different Amplatzer devices at our center between July 1999 and January 2007. All patients underwent LPRS within 24 hr of the procedure. We compared LPRS with other hemodynamic data obtained by cardiac catheterization and echocardiography. Results are presented as mean +/- SD or median and ranges. Results: A total of 70 patients had PDA closure using an Amplatzer device; median age was 1.8 years (4 months to 75 years) and median weight was 12 kg (5-112 Kg). Nine patients had associated cardiac anomalies. Sixty eight patients had available LPRS. The mean percent of left lung perfusion (LLP) was 42.7% (+/-6.7%). Excluding patients with pre-existing LPA stenosis, 17% had abnormally decreased LLP. On hemodynamic measurements, 62 patients had available direct pressure measurements following PDA closure. None had significant increase. No correlation was found with echocardiographic data. Conclusion: PDA closure with Amplatzer family of devices is associated with a relatively significant risk of decreased perfusion to the left lung, mostly mild abnormalities. Comparison with catheterization and echocardiographic measurements showed lack of correlation with LPRS findings. (C) 2011 Wiley-Liss, Inc.
引用
收藏
页码:664 / 670
页数:7
相关论文
共 50 条
  • [1] Transcatheter Closure of Patent Ductus Arteriosus Using the Amplatzer Duct Occluder in Infants Under One Year of Age
    Parra-Bravo, Rafael
    Cruz-Ramirez, Arturo
    Rebolledo-Pineda, Victor
    Robles-Cervantes, Jorge
    Chavez-Fernandez, Alejandro
    Beirana-Palencia, Luisa
    Jimenez-Montufar, Laura
    de Jesus Estrada-Loza, Maria
    Estrada-Flores, Jose
    Baez-Zamudio, Nelson
    Escobar-Ponce, Mariano
    REVISTA ESPANOLA DE CARDIOLOGIA, 2009, 62 (08): : 867 - 874
  • [2] Transcatheter closure of patent ductus arteriosus using the AMPLATZER™ duct occluder II (ADO II)
    Gruenstein, Daniel H.
    Ebeid, Makram
    Radtke, Wolfgang
    Moore, Phillip
    Holzer, Ralf
    Justino, Henri
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 89 (06) : 1118 - 1128
  • [3] Long-Term Results of Transcatheter Closure of Patent Ductus Arteriosus in Infants Using Amplatzer Duct Occluder
    Behjati-Ardakani, Mostafa
    Behjati-Ardakani, Mohammad-Amin
    Hosseini, Seyed-Habibolla
    Noori, Noormohammad
    IRANIAN JOURNAL OF PEDIATRICS, 2013, 23 (04) : 411 - 416
  • [4] Comparison of the Results of Transcatheter Closure of Patent Ductus Arteriosus with Newer Amplatzer Devices
    Liddy, Stephen
    Oslizlok, Paul
    Walsh, Kevin P.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (02) : 253 - 259
  • [5] Transcatheter Closure of Moderate-to-Large Patent Ductus Arteriosus in Infants Using Amplatzer Duct Occluder
    Wang, Jou-Kou
    Wu, Mei-Hwan
    Lin, Ming-Tai
    Chiu, Shuenn-Nan
    Chen, Chun-An
    Chiu, Hsin-Hui
    CIRCULATION JOURNAL, 2010, 74 (02) : 361 - 364
  • [6] Closure of patent ductus arteriosus with oversized Amplatzer occluder in a patient with pulmonary hypertension
    Karapinar, Hekim
    Kucukdurmaz, Zekeriya
    Oflaz, Mehmet Burhan
    Gul, Ibrahim
    Yilmaz, Ahmet
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2013, 9 (01): : 93 - 96
  • [7] Results of patent ductus arteriosus closure during adulthood using different devices
    Erdem, Abdullah
    Demir, Fadli
    Saritas, Turkay
    Akdeniz, Celal
    Zeybek, Cenap
    Yalcin, Yalim
    Aydemir, Numan Ali
    Celebi, Ahmet
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 19 (03): : 323 - 328
  • [8] Transcatheter Closure of Large Sized Patent Ductus Arteriosus Using the Amplatzer Duct Occluder Device
    Shabbir, Muhammad
    Akhtar, Khurram
    Maadullah
    Ahmed, Waqar
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2009, 19 (05): : 275 - 278
  • [9] Transcatheter closure of the patent ductus arteriosus using an amplatzer duct occluder in adults
    Lee, CH
    Leung, YL
    Chow, WH
    JAPANESE HEART JOURNAL, 2001, 42 (04): : 533 - 537
  • [10] Transcatheter closure of large patent ductus arteriosus using the Amplatzer ductal occluder
    Lin, Ming-Chih
    Fu, Yun-Ching
    Jan, Sheng-Ling
    Ho, Chi-Lin
    Chi, Ching-Shiang
    Hwang, Betau
    ACTA CARDIOLOGICA SINICA, 2007, 23 (02) : 103 - 108